The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Effect of mechanical factors on the function of engineered human blood microvessels in microfluidic collagen gels
Open accessAbstract
This work examines how mechanical signals affect the barrier function and stability of engineered human microvessels in microfluidic type I collagen gels. Constructs that were exposed to chronic low flow displayed high permeabilities to bovine serum albumin and 10 kDa dextran, numerous focal leaks, low size selectivity, and short lifespan of less than one week. Higher flows promoted barrier function and increased longevity; at the highest flows, the barrier function rivaled that observed in vivo, and all vessels survived to day 14. By studying the physiology of microvessels of different geometries, we established that shear stress and transmural pressure were the dominant mechanical signals that regulated barrier function and vascular stability, respectively. In microvessels that were exposed to high flow, elevation of intracellular cyclic AMP further increased the selectivity of the barrier and strongly suppressed cell proliferation. Computational models that incorporated stress dependence successfully predicted vascular phenotype. Our results indicate that the mechanical microenvironment plays a major role in the functionality and stability of engineered human microvessels in microfluidic collagen gels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Effect of cyclic AMP on barrier function of human lymphatic microvascular tubes
Price, G. M., Chrobak, K. M., & Tien, J. (2008) · Microvascular Research · doi:10.1016/j.mvr.2008.02.003 · Cited by 80
Self-citation
Cited by
In vitro microvessels for the study of angiogenesis and thrombosis
Zheng, Y., Chen, J., Craven, M., Choi, N. W., Totorica, S., Diaz-Santana, A., Kermani, P., Hempstead, B., Fischbach-Teschl, C., López, J. A., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1201240109 · Cited by 894
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872
Vascularization and Angiogenesis in Tissue Engineering: Beyond Creating Static Networks
Rouwkema, J., & Khademhosseini, A. (2016) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.03.002 · Cited by 651
Fluid forces control endothelial sprouting
Song, J. W., & Munn, L. L. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1105316108 · Cited by 498
Microfluidic fabrication of microengineered hydrogels and their application in tissue engineering
Chung, B. G., Lee, K.-H., Khademhosseini, A., & Lee, S.-H. (2012) · Lab Chip · doi:10.1039/c1lc20859d · Cited by 435
Metadata
- Authors
- Price, G. M., Wong, K. H. K., Truslow, J. G., Leung, A. D., Acharya, C., & Tien, J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 31
- Issue
- 24
- Pages
- 6182-6189
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2108813969
- Cited by
- 184
- References
- 2
- FWCI
- 7.65
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of mechanical factors on the function of engineered human blood microvessels in microfluidic collagen gels. https://app.cochat.ai/papers/10.1016/j.biomaterials.2010.04.041
- The paper
- Price, G. M., Wong, K. H. K., Truslow, J. G., Leung, A. D., Acharya, C., & Tien, J. (2010). Effect of mechanical factors on the function of engineered human blood microvessels in microfluidic collagen gels. Biomaterials. https://doi.org/10.1016/j.biomaterials.2010.04.041
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.