Co-electrospun dual scaffolding system with potential for muscle–tendon junction tissue engineering
The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED: Clinical transplantation of a tissue-engineered airway
Macchiarini, P., Jungebluth, P., Go, T., Asnaghi, M. A., Rees, L. E., Cogan, T. A., Dodson, A., Martorell, J., Bellini, S., Parnigotto, P. P., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)61598-6 · Cited by 1,433
RetractedTissue-engineered autologous bladders for patients needing cystoplasty
Atala, A., Bauer, S. B., Soker, S., Yoo, J. J., & Retik, A. B. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68438-9 · Cited by 1,833
Self-citationMyotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743 · cited 1×
“have shown that muscle optimally differentiates on materials that more closely match its stiffness [12].”
BackgroundThe Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
The Skeletal Muscle Satellite Cell: The Stem Cell That Came in From the Cold
Zammit, P. S., Partridge, T. A., & Yablonka-Reuveni, Z. (2006) · Journal of Histochemistry & Cytochemistry · doi:10.1369/jhc.6r6995.2006 · Cited by 689 · cited 1×
“Myotube formation on the scaffolds (as evidenced by positive MF20 staining, a marker for sarcomeric myosin present in differentiated myotubes but not myoblasts [32]) indicates that the scaffolding system is capable of accommodating the attachment of these cells and allows them to differentiate into myotubes, which is…”
BackgroundThe regulation of tendon stem cell differentiation by the alignment of nanofibers
Yin, Z., Chen, X., Chen, J. L., Shen, W. L., Hieu Nguyen, T. M., Gao, L., & Ouyang, H. W. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.083 · Cited by 626 · cited 2×
“In particular for our purposes, the use of poly(Llactic acid) (PLLA) in electrospinning results in scaffolds with high stiffness, strength, and low ductility which may be suitable for engineering tendon tissue [24].”
BackgroundMethodBaker, B. M., Gee, A. O., Metter, R. B., Nathan, A. S., Marklein, R. A., Burdick, J. A., & Mauck, R. L. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.032 · Cited by 620 · cited 1×
“Examples include applications designed to increase the porosity of scaffolds by co-electrospinning sacrificial fibers [25], improved hydrophilicity and cell attachment [26], creating hollow coreeshell fibers [27], and spinning living cells into a mesh [28].”
BackgroundChoi, J. S., Lee, S. J., Christ, G. J., Atala, A., & Yoo, J. J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.031 · Cited by 611 · cited 2×
“Additionally, a method for aligning the fibers in the scaffold in the direction of loading would also enhance the overall strength of the scaffolds as well as promote tissue differentiation and maturation as has been shown for both muscle and tendon in previous studies [22,24].”
BackgroundMethodSelf-citationPredictability of skeletal muscle tension from architectural determinations in guinea pig hindlimbs
Powell, P. L., Roy, R. R., Kanim, P., Bello, M. A., & Edgerton, V. R. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.57.6.1715 · Cited by 555
Mechanotransduction at Cell-Matrix and Cell-Cell Contacts
Chen, C. S., Tan, J., & Tien, J. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140040 · Cited by 534 · cited 1×
“In all cases, the cellular signaling mechanisms proposed for these phenomena rely onmechanotransduction [37,38].”
Background
Cited by
Electrospinning and Electrospun Nanofibers: Methods, Materials, and Applications
Xue, J., Wu, T., Dai, Y., & Xia, Y. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00593 · Cited by 5,015
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Biohybrid actuators for robotics: A review of devices actuated by living cells
Ricotti, L., Trimmer, B., Feinberg, A. W., Raman, R., Parker, K. K., Bashir, R., Sitti, M., Martel, S., Dario, P., & Menciassi, A. (2017) · Science Robotics · doi:10.1126/scirobotics.aaq0495 · Cited by 527
Qazi, T. H., Mooney, D. J., Pumberger, M., Geißler, S., & Duda, G. N. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.110 · Cited by 433
A 3D bioprinted complex structure for engineering the muscle–tendon unit
Merceron, T. K., Burt, M., Seol, Y.-J., Kang, H.-W., Lee, S. J., Yoo, J. J., & Atala, A. (2015) · Biofabrication · doi:10.1088/1758-5090/7/3/035003 · Cited by 373
Self-citationElectrospun fibers for tissue engineering, drug delivery, and wound dressing
Goh, Y.-F., Shakir, I., & Hussain, R. (2013) · Journal of Materials Science · doi:10.1007/s10853-013-7145-8 · Cited by 318
3D Bioprinting in Skeletal Muscle Tissue Engineering
Ostrovidov, S., Salehi, S., Costantini, M., Suthiwanich, K., Ebrahimi, M., Sadeghian, R. B., Fujie, T., Shi, X., Cannata, S., Gargioli, C., et al. (2019) · Small · doi:10.1002/smll.201805530 · Cited by 294
Baker, S. R., Banerjee, S., Bonin, K., & Guthold, M. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.09.102 · Cited by 224
Role of Biomaterials and Controlled Architecture on Tendon/Ligament Repair and Regeneration
No, Y. J., Castilho, M., Ramaswamy, Y., & Zreiqat, H. (2020) · Advanced Materials · doi:10.1002/adma.201904511 · Cited by 205
High‐Throughput Printing via Microvascular Multinozzle Arrays
Hansen, C. J., Saksena, R., Kolesky, D. B., Vericella, J. J., Kranz, S. J., Muldowney, G. P., Christensen, K. T., & Lewis, J. A. (2013) · Advanced Materials · doi:10.1002/adma.201203321 · Cited by 170
Biodegradable polymer nanocomposites for ligament/tendon tissue engineering
Silva, M., Ferreira, F. N., Alves, N. M., & Paiva, M. C. (2020) · Journal of Nanobiotechnology · doi:10.1186/s12951-019-0556-1 · Cited by 163
“Figure 10 shows the mechanical properties of this scaffold [108].”
BackgroundInfluentialHeidari, B. S., Chen, P., Ruan, R., Davachi, S. M., Al-Salami, H., De Juan Pardo, E., Zheng, M., & Doyle, B. (2021) · Journal of Materials Chemistry B · doi:10.1039/d0tb02971h · Cited by 23
Metadata
- Authors
- Ladd, M. R., Lee, S. J., Stitzel, J. D., Atala, A., & Yoo, J. J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2011-02
- Volume
- 32
- Issue
- 6
- Pages
- 1549-1559
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2001960823
- Cited by
- 212
- References
- 39
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.