The influence of stereolithographic scaffold architecture and composition on osteogenic signal expression with rat bone marrow stromal cells
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Scaffold design parameters, especially physical construction factors such as mechanical stiffness of substrate materials, pore size of 3D porous scaffolds, and channel geometry, are known to influence the osteogenic signal expression and subsequent differentiation of a transplanted cell population. In this study of photocrosslinked poly(propylene fumarate) (PPF) and diethyl fumarate (DEF) scaffolds, the effect of DEF incorporation ratio and pore size on the osteogenic signal expression of rat bone marrow stromal cells (BMSCs) was investigated. Results demonstrated that DEF concentrations and pore sizes that led to increased scaffold mechanical stiffness also upregulated osteogenic signal expression, including bone morphogenic protein-2 (BMP-2), fibroblast growth factors-2 (FGF-2), transforming growth factor-β1 (TGF-β1), vascular endothelial growth factor (VEGF), and Runx2 transcriptional factor. Similar scaffold fabrication parameters supported rapid BMSC osteoblastic differentiation, as demonstrated by increased alkaline phosphatase (ALP) and osteocalcin expression. When scaffolds with random architecture, fabricated by porogen leaching, were compared to those with controlled architecture, fabricated by stereolithography (SLA), results showed that SLA scaffolds with the highly permeable and porous channels also have significantly higher expression of FGF-2, TGF-β1, and VEGF. Subsequent ALP expression and osteopontin secretion were also significantly increased in SLA scaffolds. Based upon these results, we conclude that scaffold properties provided by additive manufacturing techniques such as SLA fabrication, particularly increased mechanical stiffness and high permeability, may stimulate dramatic BMSC responses that promote rapid bone tissue regeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable and bioactive porous polymer/inorganic composite scaffolds for bone tissue engineering
Rezwan, K., Chen, Q. Z., Blaker, J. J., & Boccaccini, A. R. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.01.039 · Cited by 3,839
Cited by
Recent advances in 3D printing of biomaterials
Chia, H. N., & Wu, B. M. (2015) · Journal of Biological Engineering · doi:10.1186/s13036-015-0001-4 · Cited by 1,734
Three-dimensional (3D) printed scaffold and material selection for bone repair
Zhang, L., Yang, G., Johnson, B. N., & Jia, X. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.11.039 · Cited by 865
Recent Progress on Polymer Materials for Additive Manufacturing
Tan, L. J., Zhu, W., & Zhou, K. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202003062 · Cited by 740
Bone biomaterials and interactions with stem cells
Gao, C., Peng, S., Feng, P., & Shuai, C. (2017) · Bone Research · doi:10.1038/boneres.2017.59 · Cited by 720
Self-Folding Thermo-Magnetically Responsive Soft Microgrippers
Breger, J. C., Yoon, C., Xiao, R., Kwag, H. R., Wang, M. O., Fisher, J. P., Nguyen, T. D., & Gracias, D. H. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/am508621s · Cited by 655
Self-citation
Metadata
- Authors
- Kim, K., Dean, D., Wallace, J., Breithaupt, R., Mikos, A. G., & Fisher, J. P.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2011-05
- Volume
- 32
- Issue
- 15
- Pages
- 3750-3763
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W2044203477
- Cited by
- 147
- References
- 1
- FWCI
- 7.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.