Protease-degradable PEG-maleimide coating with on-demand release of IL-1Ra to improve tissue response to neural electrodes
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Neural electrodes are an important part of brain-machine interface devices that can restore functionality to patients with sensory and movement disorders. Chronically implanted neural electrodes induce an unfavorable tissue response which includes inflammation, scar formation, and neuronal cell death, eventually causing loss of electrode function. We developed a poly(ethylene glycol) hydrogel coating for neural electrodes with non-fouling characteristics, incorporated an anti-inflammatory agent, and engineered a stimulus-responsive degradable portion for on-demand release of the anti-inflammatory agent in response to inflammatory stimuli. This coating reduces in vitro glial cell adhesion, cell spreading, and cytokine release compared to uncoated controls. We also analyzed the in vivo tissue response using immunohistochemistry and microarray qRT-PCR. Although no differences were observed among coated and uncoated electrodes for inflammatory cell markers, lower IgG penetration into the tissue around PEG+IL-1Ra coated electrodes indicates an improvement in blood-brain barrier integrity. Gene expression analysis showed higher expression of IL-6 and MMP-2 around PEG+IL-1Ra samples, as well as an increase in CNTF expression, an important marker for neuronal survival. Importantly, increased neuronal survival around coated electrodes compared to uncoated controls was observed. Collectively, these results indicate promising findings for an engineered coating to increase neuronal survival and improve tissue response around implanted neural electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Large-scale recording of neuronal ensembles
Buzsáki, G. (2004) · Nature Neuroscience · doi:10.1038/nn1233 · Cited by 1,875 · cited 1×
“However, improvement within the first 100 mm is a promising finding as electrodes can record neuronal activity to a radius of ~100 microns or more from the electrode surface [68].”
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Erickson, H. P. (2009) · Biological Procedures Online · doi:10.1007/s12575-009-9008-x · Cited by 1,571 · cited 1×
“The increased thickness for the PEGþIL-1Ra is not surprising given the incorporation of the anti-inflammatory protein (17 kDa, corresponding to a 3 nm diameter sphere [65]).”
Role of Pro-Inflammatory Cytokines Released from Microglia in Neurodegenerative Diseases
Smith, J. A., Das, A., Ray, S. K., & Banik, N. L. (2012) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2011.10.004 · Cited by 1,165 · cited 1×
“While IL-6 is traditionally considered a pro-inflammatory cytokine [69], there is evidence that it plays a role in activation of downstream cell-survival and anti-apoptotic factors [70].”
INTERLEUKIN-1 RECEPTOR ANTAGONIST: Role in Biology
Arend, W. P., Malyak, M., Guthridge, C. J., & Gabay, C. (1998) · Annual Review of Immunology · doi:10.1146/annurev.immunol.16.1.27 · Cited by 1,071
Biran, R., Martin, D. C., & Tresco, P. A. (2005) · Experimental Neurology · doi:10.1016/j.expneurol.2005.04.020 · Cited by 893
Brain-Controlled Interfaces: Movement Restoration with Neural Prosthetics
Schwartz, A. B., Cui, X. T., Weber, D. J., & Moran, D. W. (2006) · Neuron · doi:10.1016/j.neuron.2006.09.019 · Cited by 792
Matrix metalloproteinases (MMPs) in health and disease: an overview
Malemud, C. (2006) · Frontiers in Bioscience · doi:10.2741/1915 · Cited by 705
Ludwig, K. A., Uram, J. D., Yang, J., Martin, D. C., & Kipke, D. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/1/007 · Cited by 638 · cited 1×
“Conductive coatings are a widely-tested option as they can improve the electrical performance of the electrode [13,14].”
Cited by
Glial responses to implanted electrodes in the brain
Salatino, J. W., Ludwig, K. A., Kozai, T. D. Y., & Purcell, E. K. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0154-1 · Cited by 642
Macroscale biomaterials strategies for local immunomodulation
Dellacherie, M. O., Seo, B. R., & Mooney, D. J. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0106-3 · Cited by 255
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
Chronic intracortical neural recordings using microelectrode arrays coated with PEDOT–TFB
Charkhkar, H., Knaack, G. L., McHail, D. G., Mandal, H. S., Peixoto, N., Rubinson, J. F., Dumas, T. C., & Pancrazio, J. J. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.12.022 · Cited by 68
Computational assessment of neural probe and brain tissue interface under transient motion.
Polanco, M., Bawab, S., & Yoon, H. (2016) · Biosensors · doi:10.3390/bios6020027 · Cited by 36
Metadata
- Authors
- Gutowski, S. M., Shoemaker, J. T., Templeman, K. L., Wei, Y., Latour, R. A., Bellamkonda, R. V., LaPlaca, M. C., & García, A. J.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2015-03
- Volume
- 44
- Pages
- 55-70
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W1990285914
- Cited by
- 68
- References
- 17
- FWCI
- 3.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Protease-degradable PEG-maleimide coating with on-demand release of IL-1Ra to improve tissue response to neural electrodes. https://app.cochat.ai/papers/10.1016/j.biomaterials.2014.12.009
- The paper
- Gutowski, S. M., Shoemaker, J. T., Templeman, K. L., Wei, Y., Latour, R. A., Bellamkonda, R. V., LaPlaca, M. C., & García, A. J. (2015). Protease-degradable PEG-maleimide coating with on-demand release of IL-1Ra to improve tissue response to neural electrodes. Biomaterials. https://doi.org/10.1016/j.biomaterials.2014.12.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.