Construction and performance evaluation of Hep/silk-PLCL composite nanofiber small-caliber artificial blood vessel graft
The DOI matches its Crossref record.
Abstract
To meet the growing clinical demand for small-caliber blood vessel grafts to treat cardiovascular diseases, it is necessary to develop safe and long-term unobstructed grafts. In this study, a biodegradable graft made of composite nanofibers is introduced. A composite nanofiber core-shell structure was prepared by a combination of conjugate electrospinning and freeze-dry technology. The core fiber was poly(l-lactide-co-caprolactone) (PLCL)-based and the core fibers were coated with heparin/silk gel, which acted as a shell layer. This special structure in which the core layer was made of synthetic materials and the shell layer was made of natural materials took advantage of these two different materials. The core PLCL nanofibers provided mechanical support during vascular reconstruction, and the shell heparin/silk gel layer enhanced the biocompatibility of the grafts. Moreover, the release of heparin in the early stage after transplantation could regulate the microenvironment and inhibit the proliferation of intima. All of the graft materials were biodegradable and safe biomaterials, and the degradation of the graft provided space for the growth of regenerated tissue in the late stage of transplantation. Animal experiments showed that the graft remained unobstructed for more than eight months in vivo. In addition, the regenerated vascular tissue provided a similar function to that of autogenous vascular tissue when the graft was highly degraded. Thus, the proposed method produced a graft that could maintain long-term patency in vivo and remodel vascular tissue successfully.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, Q., Wei, Y., Yin, X., Zhan, G., Cao, X., & Gao, H. (2024) · Advanced Functional Materials · doi:10.1002/adfm.202400217 · Cited by 56
Liu, X., Liu, S., Feng, S., Wang, X., Bai, W., Xiao, J., Chen, D., Xiong, C., & Zhang, L. (2021) · Journal of Polymer Research · doi:10.1007/s10965-021-02802-9 · Cited by 11
Self-citationHan, Y., Wang, H., Guan, Y., Li, S., Yuan, Z., Lu, L., & Zheng, X. (2024) · Biomedical Materials · doi:10.1088/1748-605x/ad407c · Cited by 7
“In addition, PLCL can also be used to prepare small-diameter vascular scaffoldss, and some studies have made progress in improving the anticoagulation functionality and mechanical flexibility of printed PLCL structures [ 24, 25].”
MethodApplication of PLCL as a biodegradable polymer in biomedical engineering
Zhao, Y., & Liu, H. (2026) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-026-07016-3 · Cited by 7
Metadata
- Authors
- Kuang, H., Wang, Y., Shi, Y., Yao, W., He, X., Liu, X., Mo, X., Lu, S., & Zhang, P.
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2020-11
- Volume
- 259
- Pages
- 120288
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W3048555450
- Cited by
- 112
- References
- 0
- FWCI
- 2.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Construction and performance evaluation of Hep/silk-PLCL composite nanofiber small-caliber artificial blood vessel graft. https://app.cochat.ai/papers/10.1016/j.biomaterials.2020.120288
- The paper
- Kuang, H., Wang, Y., Shi, Y., Yao, W., He, X., Liu, X., Mo, X., Lu, S., & Zhang, P. (2020). Construction and performance evaluation of Hep/silk-PLCL composite nanofiber small-caliber artificial blood vessel graft. Biomaterials. https://doi.org/10.1016/j.biomaterials.2020.120288
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.