A ratiometric near-infrared fluorescence/photoacoustic dual-modal probe with strong donor dithienopyrrole for in vivo nitric oxide detection
Abstract
Integrating the imaging techniques of near-infrared fluorescence (NIRF) and photoacoustic (PA) can make up for each other and provide more useful medical information. Ratiometric imaging activated by disease-associated biomarkers can further augment imaging specificity. However, very few studies have employed the NIRF/PA dual-modal ratiometric imaging to improve the accuracy and specificity of disease diagnosis to date. In this paper, we present the synthesis of a nitric oxide (NO)-activated ratiometric NIRF/PA dual-modal nanoprobe RAPNP for in vivo NO imaging. The ratiometric imaging function was achieved jointly by a NO/acidity-responsive molecule DTP-BTDA and a nonresponsive fluorophore DTP-BBTD. In these fluorophores, the dithienopyrrole (DTP) moiety had strong electron-donating ability and imparted strong intramolecular charge transfer and relatively long emission wavelengths. The BTDA moiety in DTP-BTDA could be rapidly oxidized by NO under weak acidic environments, achieving the NIRF and PA signal activation. By using RAPNP as a contrast agent, we achieved the ratiometric detection of the endogenous NO in inflammatory bowel disease by NIRF/PA dual-modal imaging. This work provides the first case of the NIRF/PA dual-signal ratiometric probe for the real-time detection of NO in vivo.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wu et al. developed a ratiometric near-infrared fluorescence and photoacoustic dual-modal nanoprobe RAPNP for NO detection.
“Furthermore, Wu et al. developed a ratiometric near-infrared fluorescence (NIRF) and PA dual-modal nanoprobe RAPNP for NO detection134.”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [134]
In DTP-BTDA, the BTDA moiety can be rapidly oxidized by NO in a weakly acidic environment, enabling activation of NIRF and PA signals.
“In DTP-BTDA, the BTDA moiety can be rapidly oxidized by NO in a weakly acidic environment, enabling the activation of NIRF and PA signals.”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [134]
RAPNP synergistically integrates a NO/acid dual-responsive molecule, DTP-BTDA, and a nonresponsive fluorophore, DTP-BBTD.
“A key design feature was the synergistic integration of two complementary fluorophores: a NO/acid dual-responsive molecule (DTP-BTDA) and a nonresponsive fluorophore (DTP-BBTD).”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [134]
Both RAPNP fluorophores incorporated a dithienopyrrole unit as a strong electron donor, conferring a pronounced intramolecular charge transfer effect that enabled long-wavelength NIR emission for deep-tissue imaging.
“Both fluorophores incorporated a dithienopyrrole (DTP) unit as a strong electron donor. The DTP unit conferred a pronounced ICT effect, which enabled long-wavelength NIR emission crucial for deep-tissue imaging.”
From Organic small-molecule NIR-II fluorophores for tumor phototheranostics (2026) · cites this paper as [134]
Cites
Fan, X., Xia, Q., Zhang, Y., Li, Y., Feng, Z., Zhou, J., Qi, J., Tang, B. Z., Qian, J., & Lin, H. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202101043 · Cited by 94 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Liang, M., Liu, L., Sun, Y., Li, J., Zhang, L., Jiang, X., & Wu, W. (2024) · Aggregate · doi:10.1002/agt2.458 · Cited by 90 · see citing works
Self-citationMeng, X., Song, J., Du, Z., Tao, Y., & Qi, J. (2025) · ACS Nano · doi:10.1021/acsnano.5c07280 · Cited by 18 · see citing works
Organic small-molecule NIR-II fluorophores for tumor phototheranostics
Xiang, D., Wang, Z., Zheng, H., Tang, Y., & Li, Q. (2026) · Light: Science & Applications · doi:10.1038/s41377-026-02212-w · Cited by 22 · see citing works
“Furthermore, Wu et al. developed a ratiometric near-infrared fl uorescence (NIRF) and PA dual-modal nanoprobe RAPNP for NO detection 134 .”
Wang, Q., Liu, J., Yang, L., Tao, Z., Feng, J., Li, S., Wang, X., Gao, L., Tang, W., & Fan, Q. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202423165 · Cited by 15 · see citing works
Self-citation
- Authors
- Xiao, P., Liang, M., Yang, S., Sun, Y., Li, J., Gu, Z., Zhang, L., Fan, Q., Jiang, X., & Wu, W.
- Affiliations
- State Key Laboratory of Analytical Chemistry for Life Science (CN)
- Ministry of Education of the People's Republic of China (CN)
- Nanjing University of Posts and Telecommunications (CN)
- Corresponding author
- Zhang, Ling'e
- Jiang, Xiqun
- Wu, Wei
- Venue
- Biomaterials
- Publisher
- Elsevier BV
- Published
- 2023-03
- Volume
- 294
- Pages
- 121993
- ISSN
- 0142-9612 (ISSN-L)
- OpenAlex
- W4313479562
- Cited by
- 36
- References
- 1
- Citations by year
- 2026: 7 · 2025: 13 · 2024: 9 · 2023: 7
- FWCI
- 3.32
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Biomaterials (publishedVersion)
- PubMed (publishedVersion)
- Funders
- China Postdoctoral Science Foundation (2022M711544)
- National Natural Science Foundation of China (51973092, 52103157, 52173129)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
- Keywords
- nitric oxide detection, ratiometric imaging, near-infrared fluorescence, photoacoustic imaging, dual-modality imaging, dithienopyrrole, intramolecular charge transfer, inflammatory bowel disease, nanoprobes, contrast media
- MeSH terms
- Fluorescence, Fluorescent Dyes, Humans, Nitric Oxide, Photoacoustic Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review