Organic small-molecule NIR-II fluorophores for tumor phototheranostics
Open accessThe DOI matches its Crossref record; 244 of the 245 references it cites were found in a registry or an index; 80 of the 367 sources its claims cite were checked for support.
Abstract
Near-infrared II (NIR-II) fluorophores possess transformative potential for biomedical applications, owing to their deep-tissue penetration, reduced tissue autofluorescence, and low phototoxicity. Recent breakthroughs in molecular engineering have accelerated the development of NIR-II organic small-molecule fluorophores based on versatile scaffolds, including cyanine, boron dipyrromethene, benzobisthiadiazole, xanthene, cyano-based derivatives, and small-molecule metal complexes. This review systematically summarizes the molecular engineering strategies, photophysical properties, and structure-function relationships of NIR-II fluorophores in the last five years. We highlight recent breakthroughs in their theranostic applications, including high-resolution deep-tissue imaging and efficient phototherapeutic modalities such as photodynamic and photothermal therapy. Finally, we present forward-looking perspectives on current challenges and emerging opportunities, aiming to provide insights for promoting continued innovation and clinical translation in this rapidly advancing field.
Overview
CoChat Summary
TL;DR
This review surveys organic small-molecule NIR-II fluorophores built on cyanine, BODIPY, BBTD, xanthene, cyano-based, and small-molecule metal-complex scaffolds, covering molecular design strategies, photophysical properties, and structure–function relationships over the last five years. It then catalogs their use in deep-tissue fluorescence/photoacoustic imaging, image-guided surgery, and photodynamic/photothermal tumor therapy, and closes with translational challenges.
Key findings
- Emission red-shifting is achieved mainly by polymethine-chain elongation, donor/acceptor engineering, π-conjugation extension, and heteroatom substitution; each added methylene unit typically gives ~100 nm red-shift but plateaus as chains become conformationally flexible and prone to non-radiative decay.
- Reported performance highlights include: CTB1125 with λem 1125 nm and 10.2% quantum yield in hexane (4.84% in water), described as surpassing all previously reported fluorophores emitting beyond 1100 nm; FE-IDMN NPs with PCE 82.6%; BETT-2 NPs with PCE 56.6%; DPTPzIr NPs with PCE 60.5%; and mCy890 NPs with PCE 51%.
- Imaging benchmarks cited include SJ-1271-Micelles NIR-IIb vascular SNRs of 6.79 (hindlimb), 3.39 (abdomen), 5.87 (brain) and tumor TNR/SNR peaking at 3.0/4.76; NIR-AC4 Bio NPs reaching TNR 15 and AaNPs SBR 14.32; FBP 912 with t1/2 ≈ 6.1 h, SNR 8.2, and 65% renal clearance at 12 h; and 5SGNPs with pulmonary SNR of 124.
- Activatable and targeted designs (pH/viscosity, GSH, H2S, NO, ATP, ROS, APN, CA, GLUT1, mitochondria) are presented as the main route to overcome the "always-on" background and hepatic accumulation of conventional cyanines.
Methods
- Narrative review, not primary research: the authors systematically summarize molecular engineering strategies, photophysical properties, and structure–function relationships of NIR-II organic small-molecule fluorophores published in the last five years.
- Evidence base is the published literature, organized by scaffold class (cyanine, BBTD, BODIPY, xanthene, cyano-based, small-molecule metal complexes) with six accompanying tables of λabs, λem, quantum yield, and molar extinction coefficient values and their original references.
- Applications are grouped into bioimaging (fluorescence and photoacoustic) and phototherapy (PDT, PTT, gas therapy, synergistic combinations), with representative in vivo mouse models (4T1, H22, MCF-7, CT26, GL261, Pan02, A549, HCT-116, HepG2) described qualitatively.
Limitations
- Stated by the authors: insufficient fluorescence intensity (low quantum yields, worsened by water-induced non-radiative relaxation); poor water solubility and biocompatibility, with PEGylation/nanoparticle assembly often causing rapid hepatic uptake and an unresolved trade-off between extended conjugation and hydrophilicity; inadequate targeting ability and specificity, with many systems lacking quantitative comparisons of targeting efficiency; and limited blood-brain barrier penetration, where systematic evaluation of penetration efficiency, long-term biosafety, and clinical relevance is scarce.
- Evident from the text: as a review, it reports no new experimental data, and the performance figures cited are drawn from heterogeneous primary studies using differing solvents, reference standards for quantum yield (IR-26, ICG, IR-1061, ECXb, FT-BBT, single-walled carbon nanotubes), and measurement conditions, so cross-study comparisons are not normalized.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Figures


























Verification
Claims the paper makes
68 Valid · 2 Not valid · 232 Not checked · 41 Own results and interpretations
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Despite the significant advantages of organic small-molecule fluorescent probes, clinically approved agents available for tumor detection and therapy remain extremely limited (e.g., methylene blue, indocyanine green (ICG))63–66.”
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Introduction
What the sources say
- Not checked — no full text of the sourcecites [63] He, K. S. et al. Comparison between the indocyanine green fluorescence and blue dye methods for sentinel lymph node biopsy using novel fluorescence image-guided resection equipment in different types of hospitals. Transl. Res. 178, 74–80 (2016). 27497181 source
- Partly supportedcites [64] van Manen, L. et al. A practical guide for the use of indocyanine green and methylene blue in fluorescence-guided abdominal surgery. J. Surg. Oncol. 118, 283–300 (2018). 29938401 PMC6175214 sourceExperimental — accuracy not yet measured
The Introduction says that only indocyanine green and methylene blue among the NIR fluorophores discussed are approved for clinical use. The Tumor Imaging section describes ICG use for tumor detection. The paper does not establish that either agent is clinically approved for tumor therapy, so the therapy portion of the claim is unsupported. (LLM, conf=0.88)
- Partly supportedcites [65] Carr, J. A. et al. Shortwave infrared fluorescence imaging with the clinically approved near-infrared dye indocyanine green. Proc. Natl. Acad. Sci. USA 115, 4465–4470 (2018). 29626132 PMC5924901 sourceExperimental — accuracy not yet measured
The Abstract (page not provided) identifies indocyanine green as FDA-approved and lists cancer localization among applications of it and other near-infrared dyes. It describes a shortage of approved dyes specifically for shortwave-infrared imaging, not a general shortage of approved agents for tumor detection and therapy. The cited paper does not identify methylene blue as an example. (LLM, conf=0.87)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Significant red-shifts in emission wavelength are primarily achieved through two strategies: elongation of the polymethine chain and fine structural modifications, including extension or modification of terminal heterocycles, electron-donating or withdrawing substituents on terminal units and cyclization of the polymethine chain111–113.”
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Molecular design > Cyanine-based fluorophores
What the sources say
- Partly supportedcites [111] Friedman, H. C. et al. Establishing design principles for emissive organic SWIR chromophores from energy gap laws. Chem 7, 3359–3376 (2021). 34901520 PMC8664240 sourceExperimental — accuracy not yet measured
The Introduction and Results section on comparing chromophore quantum yields (page numbers unavailable) report that electron-donating groups on the heterocycle red-shift the flavylium polymethine scaffold. The passages do not establish chain elongation, electron-withdrawing substituents, terminal-heterocycle extension, or polymethine-chain cyclization as red-shifting strategies, nor that the listed strategies are the primary ones. (LLM, conf=0.85)
- Not checked — no full text of the sourcecites [112] Gopika, G. S. et al. Chemistry of cyanine dyes-a review. Mater. Today Proc. 46, 3102–3108 (2021). source
- Not checked — no full text of the sourcecites [113] Medeiros, N. G. et al. Near-infrared fluorophores based on heptamethine cyanine dyes: from their synthesis and photophysical properties to recent optical sensing and bioimaging applications. Asian J. Org. Chem. 11, e202200095 (2022). source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“A general rule, as exemplified in cyanine dyes, is that each methylene unit inserted between donor and acceptor typically induces a red-shift of ~100 nm111–123.”
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Molecular design > Xanthene-based fluorophores
What the sources say
- Could not verifycites [111] Friedman, H. C. et al. Establishing design principles for emissive organic SWIR chromophores from energy gap laws. Chem 7, 3359–3376 (2021). 34901520 PMC8664240 sourceExperimental — accuracy not yet measured
The Results section on chromophore quantum yield links red-shifting to electron-donating groups, not to inserting methylene units between donor and acceptor. Searches for “methylene,” “100 nm,” and polymethine-chain length found no passage stating the claimed per-unit rule; the available passages have no page numbers. (LLM, conf=0.72)
- Not checked — no full text of the sourcecites [112] Gopika, G. S. et al. Chemistry of cyanine dyes-a review. Mater. Today Proc. 46, 3102–3108 (2021). source
- Not checked — no full text of the sourcecites [113] Medeiros, N. G. et al. Near-infrared fluorophores based on heptamethine cyanine dyes: from their synthesis and photophysical properties to recent optical sensing and bioimaging applications. Asian J. Org. Chem. 11, e202200095 (2022). source
- Not checked — no full text of the sourcecites [114] Du, J. et al. Highly stable and bright NIR-II AIE dots for intraoperative identification of ureter. ACS Appl. Mater. Interfaces 12, 8040–8049 (2020). 31970976 source
- Not checked — no full text of the sourcecites [115] Fang, Y. et al. Design, synthesis, and application of a small molecular NIR-II fluorophore with maximal emission beyond 1200 nm. J. Am. Chem. Soc. 142, 15271–15275 (2020). 32820908 source
- Not checked — no full text of the sourcecites [116] Li, S. L. et al. in vivo real-time pharmaceutical evaluations of near-infrared II fluorescent nanomedicine bound polyethylene glycol ligands for tumor photothermal ablation. ACS Nano 14, 13681–13690 (2020). 32926626 source
- Not checked — no full text of the sourcecites [117] Lin, J. C. et al. A novel small-molecule near-infrared II fluorescence probe for orthotopic osteosarcoma imaging. Sci. China Chem. 63, 766–770 (2020). source
- Not checked — no full text of the sourcecites [118] Wang, S. W. et al. NIR-II light activated photosensitizer with aggregation-induced emission for precise and efficient two-photon photodynamic cancer cell ablation. Adv. Funct. Mater. 30, 2002546 (2020). source
- Not checked — no full text of the sourcecites [119] Cheng, Z. J. et al. D-A-D structured selenadiazolesbenzothiadiazole-based near-infrared dye for enhanced photoacoustic imaging and photothermal cancer therapy. Chin. Chem. Lett. 32, 1580–1585 (2021). source
- Not checked — no full text of the sourcecites [120] Fan, X. X. et al. Aggregation-induced emission (AIE) nanoparticles-assisted NIR-II fluorescence imaging-guided diagnosis and surgery for inflammatory bowel disease (IBD). Adv. Healthc. Mater. 10, 2101043 (2021). 34319657 source
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“Traditional Cr(III) polypyridyl complexes typically emit in the 727–778 nm range, limited to the red/NIR-I region.”
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Molecular design > Small-molecule metal complexes
What the sources say
- Supportedcites [194] Sinha, N. et al. A near-infrared-II emissive chromium(III) complex. Angew. Chem. Int. Ed. 60, 23722–23728 (2021). PMC8597102 34125469 source
The Abstract states that previously explored Cr(III) polypyridine complexes typically emit between 727 and 778 nm, in the red to NIR-I spectral region. The Introduction likewise gives 727–778 nm for the emission peaks of the earlier complexes in Figure 1. (LLM, conf=0.95)
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Lymphatic metastasis is a key mechanism by which cancer cells detach from the primary tumor, migrate to adjacent regional lymph nodes, and eventually spread to other organs or body sites222.”
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Organic small-molecule NIR-II fluorophores for bioimaging > Cyano-based fluorophores
What the sources say
- Partly supportedcites [222] Sennino, B. et al. Inhibition of c-Met reduces lymphatic metastasis in RIP-Tag2 transgenic mice. Cancer Res. 73, 3692–3703 (2013). 23576559 PMC3686901 sourceExperimental — accuracy not yet measured
The Introduction (page unavailable) says tumor cells enter lymphatics within or near tumors and drain to regional sentinel nodes, supporting the lymph-node portion of the claim. Our copy does not establish that those cells subsequently spread from the nodes to other organs or body sites. (LLM, conf=0.87)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
155 more claims · 27 with their cited sources checked
Create a free account to see all 343 claims and to verify the 11 references still open.
- It may state two separate claims as one. 160
- Probably not a substantial claim. 27
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Molecular design > Xanthene-based fluorophores
“| GX-5 | 875 | / | 0.424a (MeOH) | 3.04 × 104 | 184 |”
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Molecular design > Xanthene-based fluorophores
“the optimized GX-5 scaffold exhibited absorption/emission maxima at 1082/1360 nm.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Organic small-molecule NIR-II fluorophores for bioimaging > Cyanine-based fluorophores
“When paired with the albumin-escaping probe IR-800Ac, C7-1080 enabled real-time dual-channel imaging of BBB leakage and cerebral vessels.”
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Organic small-molecule NIR-II fluorophores for bioimaging > Cyanine-based fluorophores
“iii) Dynamic imaging of sham/stroke mice following tail vein injection of C7-1080 or IR-808Ac.”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Organic small-molecule NIR-II fluorophores for bioimaging > Cyanine-based fluorophores
“Following intravenous injection, SJ-1271-Micelles enabled clear discrimination between tumors and adjacent normal tissues in orthotopic 4T1 tumor-bearing mice”
§ Organic small-molecule NIR-II fluorophores for tumor phototheranostics > Organic small-molecule NIR-II fluorophores for bioimaging > Cyanine-based fluorophores
“iii) Abdominal NIR-II imaging of orthotopic 4T1 tumor-bearing mice following injection of SJ-1249-Micelles.”
Citations
Cites
Clinical development and potential of photothermal and photodynamic therapies for cancer
Li, X., Lovell, J. F., Yoon, J., & Chen, X. (2020) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-020-0410-2 · Cited by 3,456 · cited 1×
“PTT leverages localized hyperthermia generated by photothermal agents, while PDT utilizes cytotoxic reactive oxygen species (ROS) generated by excited photo-sensitizers 9 – 11 .”
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848 · cited 1×
“The foremost challenge in achieving high-performance deep-tissue NIR-II imaging lies in the development of fl uorescent probes that exhibit bright emission within this window 42,43 .”
Recent Strategies to Develop Innovative Photosensitizers for Enhanced Photodynamic Therapy
Pham, T. C., Nguyen, V.-N., Choi, Y., Lee, S., & Yoon, J. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00381 · Cited by 1,813 · cited 1×
“PDT utilizing next-generation metal-based photosensitizers with extended excitation and emission spectra holds signi fi cant promise for antibacterial applications 16,241 .”
A small-molecule dye for NIR-II imaging
Antaris, A. L., Chen, H., Cheng, K., Sun, Y., Hong, G., Qu, C., Diao, S., Deng, Z., Hu, X., Zhang, B., et al. (2016) · Nature Materials · doi:10.1038/nmat4476 · Cited by 1,778
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287 · cited 1×
“…NIR-II imaging in 2009, the fi eld has witnessed remarkable progress, leading to the emergence of diverse probe materials, including carbon nanotubes 44,45 , quantum dots 46 – 48 , rare-earth-doped nanoparticles 49 – 51 , conjugated polymers 52 , and organic small-molecule dyes 53 – 58 .”
Hu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126 · cited 3×
“Com-pounding this issue, signi fi cant liver accumulation of these dyes generates intense background fl uorescence, further compromising imaging accuracy 66 .”
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021 · cited 1×
“The foremost challenge in achieving high-performance deep-tissue NIR-II imaging lies in the development of fl uorescent probes that exhibit bright emission within this window 42,43 .”
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995 · cited 1×
“Among the diverse optical imaging modalities, fl uorescence imaging within the near-infrared II (NIR-II, 1000 – 1700 nm) window represents a major leap forward compared with those operating in the visible (400 – 700 nm) and near-infrared I (NIR-I, 700 – 1000 nm) regions 34 – 37 .”
Cited by
Counterion effects on photophysical properties of cationic organic fluorophores
Han, Y. R., & Lee, S. B. (2026) · Dyes and Pigments · doi:10.1016/j.dyepig.2026.113953
Wu, W., Liu, B., Huang, L., Xu, Y., You, C., Chen, K., Yang, H., Chen, J., Huang, R., & Peng, Y. (2026) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2026.128329
Martinelli, S., Peri, S., Anceschi, C., Laurenzana, A., Menna, N. D., Fortuna, L., Passagnoli, F., & Cianchi, F. (2026) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2026.108695 · Cited by 1
Zhu, S., Xiao, S., Chen, X. L., Wang, H., Zhang, Z., Gan, X., Ding, J., & Meng, G. (2026) · Chemical Science · doi:10.1039/d6sc04042j
Ran, X., Zhang, Y.-M., Xia, W.-L., Li, L.-X., Zhang, F., Cao, Y.-S., Yu, X.-Q., & Li, K. (2026) · ACS Nano · doi:10.1021/acsnano.6c08317 · Cited by 2
Metadata
- Authors
- Xiang, D., Wang, Z., Zheng, H., Tang, Y., & Li, Q.
- Affiliations
- Southeast University (CN)
- Kent State University (US)
- Corresponding author
- Tang, Yuqi
- Li, Quan
- Venue
- Light: Science & Applications
- Published
- 2026-03-16
- Volume
- 15
- Issue
- 1
- ISSN
- 2047-7538 (ISSN-L)
- PMC
- PMC12992625
- OpenAlex
- W7136297032
- Cited by
- 22
- References
- 123
- Citations by year
- 2026: 22
- FWCI
- 7.18
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0 (tdm)
- creativecommons.org/licenses/by/4.0 (vor)
- Locations
- Light Science & Applications (publishedVersion, cc-by)
- PubMed (publishedVersion)
- PubMed Central (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Physical Sciences › Engineering › Biomedical Engineering › Nanoplatforms for cancer theranostics
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Keywords
- NIR-II fluorophores, deep tissue imaging, photodynamic therapy, photothermal therapy, cyanine dyes, boron dipyrromethene, benzobisthiadiazole, xanthene derivatives, structure-function relationship, photophysical properties, molecular engineering
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Organic small-molecule NIR-II fluorophores for tumor phototheranostics. https://app.cochat.ai/papers/10.1038/s41377-026-02212-w
- The paper
- Xiang, D., Wang, Z., Zheng, H., Tang, Y., & Li, Q. (2026). Organic small-molecule NIR-II fluorophores for tumor phototheranostics. Light: Science & Applications. https://doi.org/10.1038/s41377-026-02212-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.