Microcavity array (MCA)-based biosensor chip for functional drug screening of 3D tissue models

Kloß, Daniel, Kurz, Randy, Jahnke, Heinz-Georg, Fischer, Michael, Rothermel, Andrée, Anderegg, Ulf, Simon, Jan C., Robitzki, Andrea A.·2008·Biosensors and Bioelectronics

Abstract

Multicellular tumour spheroids that mimic a native cellular environment are widely used as model systems for drug testing. To study drug effects on three-dimensional cultures in real-time we designed and fabricated a novel type of sensor chip for fast, non-destructive impedance spectroscopy and extracellular recording. Precultured spheroids are trapped between four gold electrodes. Fifteen individual 100microm deep square microcavities with sizes from 200 to 400microm allow an optimised positioning during the measurement. Although apoptosis was induced in human melanoma spheroids by Camptothecin (CTT), treated cultures did not show disintegration but displayed increased impedance magnitudes compared to controls after 8h resulting from an altered morphology of the outer cells. Contractions in cardiomyocyte spheroids were monitored when the innovative chip was used for recording of extracellular potentials. The silicon-based electrode array is used as an acute test system for the monitoring of any kind of 3D cell cultures. Since no adherence of cells or labelling is necessary the multifunctional sensor chip provides a basis for improved drug development by high content screenings with reduced costs and assay times. Additional improvements for parallel testing of different substances on one chip are presented.

Integrity signals

Registry

Crossref · 10.1016/j.bios.2008.01.003

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In microcavity and microcapillary designs, it is important that the size of the cavity or capillary match the size of spheroids, allowing the spheroids to be adequately analyzed by maintaining their shape and properties during measurements.

    “In both the microcavity and the microcapillary designs, it is important that the size of the cavity or capillary match with the size of spheroids, allowing the spheroids to be adequately analyzed by maintaining their shape and properties during measurements. 88”
  • Kloss et al. demonstrated that drug-induced apoptosis in spheroids displayed increased impedance magnitudes, resulting from an altered morphology of the outer cells, using the microcavity system.

    “Kloss et al . demonstrated that drug-induced apoptosis in spheroids displayed increased impedance magnitudes, resulting from an altered morphology of the outer cells, using the microcavity system. 88”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kloß, D., Kurz, R., Jahnke, H.-G., Fischer, M., Rothermel, A., Anderegg, U., Simon, J. C., & Robitzki, A. A.
Affiliations
  • Leipzig University (DE)
  • Technische Universität Ilmenau (DE)
  • University Hospital Leipzig (DE)
Corresponding author
Robitzki, Andrea A.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2008-05
Volume
23
Issue
10
Pages
1473-1480
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2000315568
Cited by
77
References
18
Citations by year
2025: 1 · 2024: 3 · 2023: 1 · 2022: 3 · 2021: 4 · 2020: 11 · 2019: 7 · 2018: 4 · 2017: 5 · 2016: 3 · 2015: 1 · 2014: 7 · 2013: 5 · 2012: 7
FWCI
2.15
Type
journal article
Language
en
Open access
closed
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • PubMed (publishedVersion)
Funders
Deutsche Forschungsgemeinschaft
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
Keywords
microcavity arrays, sensor chip, impedance spectroscopy, tumor spheroids, 3D cell culture, drug screening, high-content screening, apoptosis, camptothecin, cardiomyocyte contraction, gold electrode, real-time monitoring
MeSH terms
Biological Assay, Drug Evaluation, Preclinical, Equipment Design, Spectrum Analysis, Biosensing Techniques, Electric Impedance, Neoplasms, Bone Tissue, Cell Culture Techniques, Equipment Failure Analysis, Microfluidic Analytical Techniques, Tissue Array Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review