The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Fabrication of a glucose sensor based on a novel nanocomposite electrode
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose oxidase: an ideal enzyme
Wilson, R., & Turner, A. P. F. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)87013-f · Cited by 1,350
Glucose Biosensors Based on Carbon Nanotube Nanoelectrode Ensembles
Lin, Y., Lu, F., Tu, Y., & Ren, Z. (2004) · Nano Letters · doi:10.1021/nl0347233 · Cited by 895
Electroanalytical and Bioelectroanalytical Systems Based on Metal and Semiconductor Nanoparticles
Katz, E., Willner, I., & Wang, J. (2004) · Electroanalysis · doi:10.1002/elan.200302930 · Cited by 738
Nonenzymatic Glucose Detection Using Mesoporous Platinum
Park, S., Chung, T. D., & Kim, H. C. (2003) · Analytical Chemistry · doi:10.1021/ac0263465 · Cited by 594
Kang, X., Mai, Z., Zou, X., Cai, P., & Mo, J. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.01.003 · Cited by 572
Nonenzymatic Electrochemical Glucose Sensor Based on Nanoporous PtPb Networks
Wang, J., Thomas, D. F., & Chen, A. (2008) · Analytical Chemistry · doi:10.1021/ac701790z · Cited by 534
Li, Y., Song, Y.-Y., Yang, C., & Xia, X.-H. (2007) · Electrochemistry Communications · doi:10.1016/j.elecom.2006.11.035 · Cited by 515
High-Performance Carbon Composite Electrode Based on an Ionic Liquid as a Binder
Maleki, N., Safavi, A., & Tajabadi, F. (2006) · Analytical Chemistry · doi:10.1021/ac060070+ · Cited by 504
Self-citationAn improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrode
Zhuang, Z., Su, X., Yuan, H., Sun, Q., Xiao, D., & Choi, M. M. F. (2008) · The Analyst · doi:10.1039/b712970j · Cited by 481
Highly Ordered Platinum‐Nanotubule Arrays for Amperometric Glucose Sensing
Yuan, J. H., Wang, K., & Xia, X. H. (2005) · Advanced Functional Materials · doi:10.1002/adfm.200400321 · Cited by 432
Cited by
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
Electrospun Co3O4 nanofibers for sensitive and selective glucose detection
Ding, Y., Wang, Y., Su, L., Bellagamba, M., Zhang, H., & Lei, Y. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.050 · Cited by 707
A Critical Review of Glucose Biosensors Based on Carbon Nanomaterials: Carbon Nanotubes and Graphene
Zhu, Z., Garcia-Gancedo, L., Flewitt, A. J., Xie, H., Moussy, F., & Milne, W. I. (2012) · Sensors · doi:10.3390/s120505996 · Cited by 549
Application of ionic liquids in electrochemical sensing systems
Shiddiky, M. J. A., & Torriero, A. A. J. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.064 · Cited by 408
Metadata
- Authors
- Safavi, A., Maleki, N., & Farjami, E.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 24
- Issue
- 6
- Pages
- 1655-1660
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2078370504
- Cited by
- 296
- References
- 26
- FWCI
- 14.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fabrication of a glucose sensor based on a novel nanocomposite electrode. https://app.cochat.ai/papers/10.1016/j.bios.2008.08.040
- The paper
- Safavi, A., Maleki, N., & Farjami, E. (2009). Fabrication of a glucose sensor based on a novel nanocomposite electrode. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2008.08.040
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).