The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Nano-bio-chips for high performance multiplexed protein detection: Determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels
Open accessAbstract
The integration of semiconductor nanoparticle quantum dots (QDs) into a modular, microfluidic biosensor for the multiplexed quantitation of three important cancer markers, carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), and Her-2/Neu (C-erbB-2) was achieved. The functionality of the integrated sample processing, analyte capture and detection modalities was demonstrated using both serum and whole saliva specimens. Here, nano-bio-chips that employed a fluorescence transduction signal with QD-labeled detecting antibody were used in combination with antigen capture by a microporous agarose bead array supported within a microfluidics ensemble so as to complete the sandwich-type immunoassay. The utilization of QD probes in this miniaturized biosensor format resulted in signal amplification 30 times relative to that of standard molecular fluorophores as well as affording a reduction in observed limits of detection by nearly 2 orders of magnitude (0.02 ng/mL CEA; 0.11 pM CEA) relative to enzyme-linked immunosorbent assay (ELISA). Assay validation studies indicate that measurements by the nano-bio-chip system correlate to standard methods at R2 = 0.94 and R2 = 0.95 for saliva and serum, respectively. This integrated nano-bio-chip assay system, in tandem with next-generation fluorophores, promises to be a sensitive, multiplexed tool for important diagnostic and prognostic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bhasin, S., Zhang, A., Coviello, A., Jasuja, R., Ulloor, J., Singh, R., Vesper, H., & Vasan, R. S. (2008) · Steroids · doi:10.1016/j.steroids.2008.07.003 · Cited by 79
Cited by
Quantum dots in biomedical applications
Wagner, A. M., Knipe, J. M., Orive, G., & Peppas, N. A. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.022 · Cited by 632
Jokerst, J. V., Cole, A. J., Van de Sompel, D., & Gambhir, S. S. (2012) · ACS Nano · doi:10.1021/nn304347g · Cited by 397
Self-citationApplication of semiconductor quantum dots in bioimaging and biosensing
Martynenko, I. V., Litvin, A. P., Purcell-Milton, F., Baranov, A. V., Fedorov, A. V., & Gun'ko, Y. K. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01425b · Cited by 382
Cancer detection using nanoparticle-based sensors
Perfézou, M., Turner, A., & Merkoçi, A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15134g · Cited by 364
Application of Nanotechnology in Cancer Diagnosis and Therapy - A Mini-Review
Jin, C., Wang, K., Oppong-Gyebi, A., & Hu, J. (2020) · International Journal of Medical Sciences · doi:10.7150/ijms.49801 · Cited by 353
Metadata
- Authors
- Jokerst, J. V., Raamanathan, A., Christodoulides, N., Floriano, P. N., Pollard, A. A., Simmons, G. W., Wong, J., Gage, C., Furmaga, W. B., Redding, S. W., & McDevitt, J. T.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2009-08
- Volume
- 24
- Issue
- 12
- Pages
- 3622-3629
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2119624780
- Cited by
- 253
- References
- 1
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nano-bio-chips for high performance multiplexed protein detection: Determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels. https://app.cochat.ai/papers/10.1016/j.bios.2009.05.026
- The paper
- Jokerst, J. V., Raamanathan, A., Christodoulides, N., Floriano, P. N., Pollard, A. A., Simmons, G. W., Wong, J., Gage, C., Furmaga, W. B., Redding, S. W., & McDevitt, J. T. (2009). Nano-bio-chips for high performance multiplexed protein detection: Determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2009.05.026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.