The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Nano-bio-chips for high performance multiplexed protein detection: Determinations of cancer biomarkers in serum and saliva using quantum dot bioconjugate labels
Open accessAbstract
The integration of semiconductor nanoparticle quantum dots (QDs) into a modular, microfluidic biosensor for the multiplexed quantitation of three important cancer markers, carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), and Her-2/Neu (C-erbB-2) was achieved. The functionality of the integrated sample processing, analyte capture and detection modalities was demonstrated using both serum and whole saliva specimens. Here, nano-bio-chips that employed a fluorescence transduction signal with QD-labeled detecting antibody were used in combination with antigen capture by a microporous agarose bead array supported within a microfluidics ensemble so as to complete the sandwich-type immunoassay. The utilization of QD probes in this miniaturized biosensor format resulted in signal amplification 30 times relative to that of standard molecular fluorophores as well as affording a reduction in observed limits of detection by nearly 2 orders of magnitude (0.02 ng/mL CEA; 0.11 pM CEA) relative to enzyme-linked immunosorbent assay (ELISA). Assay validation studies indicate that measurements by the nano-bio-chip system correlate to standard methods at R2 = 0.94 and R2 = 0.95 for saliva and serum, respectively. This integrated nano-bio-chip assay system, in tandem with next-generation fluorophores, promises to be a sensitive, multiplexed tool for important diagnostic and prognostic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1968) · American Association of Industrial Nurses Journal · doi:10.1177/216507996801601208 · Cited by 8,798
Quantum dots versus organic dyes as fluorescent labels
Resch-Genger, U., Grabolle, M., Cavaliere-Jaricot, S., Nitschke, R., & Nann, T. (2008) · Nature Methods · doi:10.1038/nmeth.1248 · Cited by 3,833
Harris, L., Fritsche, H., Mennel, R., Norton, L., Ravdin, P., Taube, S., Somerfield, M. R., Hayes, D. F., & Bast, R. C. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.2364 · Cited by 2,217
Alexa Dyes, a Series of New Fluorescent Dyes that Yield Exceptionally Bright, Photostable Conjugates
Panchuk-Voloshina, N., Haugland, R. P., Bishop-Stewart, J., Bhalgat, M. K., Millard, P. J., Mao, F., Leung, W.-Y., & Haugland, R. P. (1999) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549904700910 · Cited by 881
Compact Biocompatible Quantum Dots Functionalized for Cellular Imaging
Liu, W., Howarth, M., Greytak, A. B., Zheng, Y., Nocera, D. G., Ting, A. Y., & Bawendi, M. G. (2008) · Journal of the American Chemical Society · doi:10.1021/ja076069p · Cited by 612
Review: The physiology of saliva and transfer of drugs into saliva
Aps, J. K. M., & Martens, L. C. (2005) · Forensic Science International · doi:10.1016/j.forsciint.2004.10.026 · Cited by 560
Bioconjugated quantum dots for multiplexed and quantitative immunohistochemistry
Xing, Y., Chaudry, Q., Shen, C., Kong, K. Y., Zhau, H. E., Chung, L. W., Petros, J. A., O'Regan, R. M., Yezhelyev, M. V., Simons, J. W., et al. (2007) · Nature Protocols · doi:10.1038/nprot.2007.107 · Cited by 528
Microfluidic immunoassays as rapid saliva-based clinical diagnostics
Herr, A. E., Hatch, A. V., Throckmorton, D. J., Tran, H. M., Brennan, J. S., Giannobile, W. V., & Singh, A. K. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0607254104 · Cited by 389
Point-of-care biosensor systems for cancer diagnostics/prognostics
Soper, S. A., Brown, K., Ellington, A., Frazier, B., Garcia-Manero, G., Gau, V., Gutman, S. I., Hayes, D. F., Korte, B., Landers, J. L., et al. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.006 · Cited by 376
Crowther, J. R. (2003) · ELISA · doi:10.1385/0-89603-279-5:1 · Cited by 281
Cited by
Nanoparticle Probes for the Detection of Cancer Biomarkers, Cells, and Tissues by Fluorescence
Chinen, A. B., Guan, C. M., Ferrer, J. R., Barnaby, S. N., Merkel, T. J., & Mirkin, C. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00321 · Cited by 1,032
Quantum dots in biomedical applications
Wagner, A. M., Knipe, J. M., Orive, G., & Peppas, N. A. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.022 · Cited by 632
Jokerst, J. V., Cole, A. J., Van de Sompel, D., & Gambhir, S. S. (2012) · ACS Nano · doi:10.1021/nn304347g · Cited by 397
Self-citationApplication of semiconductor quantum dots in bioimaging and biosensing
Martynenko, I. V., Litvin, A. P., Purcell-Milton, F., Baranov, A. V., Fedorov, A. V., & Gun'ko, Y. K. (2017) · Journal of Materials Chemistry B · doi:10.1039/c7tb01425b · Cited by 382
Cancer detection using nanoparticle-based sensors
Perfézou, M., Turner, A., & Merkoçi, A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15134g · Cited by 364
Application of Nanotechnology in Cancer Diagnosis and Therapy - A Mini-Review
Jin, C., Wang, K., Oppong-Gyebi, A., & Hu, J. (2020) · International Journal of Medical Sciences · doi:10.7150/ijms.49801 · Cited by 353
Semiconductor Quantum Dots in Bioanalysis: Crossing the Valley of Death
Algar, W. R., Susumu, K., Delehanty, J. B., & Medintz, I. L. (2011) · Analytical Chemistry · doi:10.1021/ac201331r · Cited by 347
Immunoassays in microfluidic systems
Ng, A. H. C., Uddayasankar, U., & Wheeler, A. R. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3678-8 · Cited by 345
Nanotechnology for Early Cancer Detection
Choi, Y.-E., Kwak, J.-W., & Park, J. W. (2010) · Sensors · doi:10.3390/s100100428 · Cited by 329
Microfluidics Based Point‐of‐Care Diagnostics
Pandey, C. M., Augustine, S., Kumar, S., Kumar, S., Nara, S., Srivastava, S., & Malhotra, B. D. (2018) · Biotechnology Journal · doi:10.1002/biot.201700047 · Cited by 273
Saliva-Based Biosensors: Noninvasive Monitoring Tool for Clinical Diagnostics
Malon, R. S. P., Sadir, S., Balakrishnan, M., & Córcoles, E. P. (2014) · BioMed Research International · doi:10.1155/2014/962903 · Cited by 260
Dong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
A Review on Saliva-Based Health Diagnostics: Biomarker Selection and Future Directions
Kumari, S., Samara, M., Ampadi Ramachandran, R., Gosh, S., George, H., Wang, R., Pesavento, R. P., & Mathew, M. T. (2024) · Biomedical Materials & Devices · doi:10.1007/s44174-023-00090-z · Cited by 95
Electrochemical bioaffinity sensors for salivary biomarkers detection
Campuzano, S., Yánez-Sedeño, P., & Pingarrón, J. M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.10.002 · Cited by 81
Recent advances in microfluidic methods in cancer liquid biopsy
Iliescu, F. S., Poenar, D. P., Yu, F., Ni, M., Chan, K. H., Cima, I., Taylor, H. K., Cima, I., & Iliescu, C. (2019) · Biomicrofluidics · doi:10.1063/1.5087690 · Cited by 51
Metadata
- Authors
- Jokerst, J. V., Raamanathan, A., Christodoulides, N., Floriano, P. N., Pollard, A. A., Simmons, G. W., Wong, J., Gage, C., Furmaga, W. B., Redding, S. W., & McDevitt, J. T.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2009-08
- Volume
- 24
- Issue
- 12
- Pages
- 3622-3629
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2119624780
- Cited by
- 253
- References
- 29
- FWCI
- 9.96
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.