The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Enhanced lateral flow immunoassay using gold nanoparticles loaded with enzymes
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A study of the nucleation and growth processes in the synthesis of colloidal gold
Turkevich, J., Stevenson, P. C., & Hillier, J. (1951) · Discussions of the Faraday Society · doi:10.1039/df9511100055 · Cited by 7,792
Microfluidic diagnostic technologies for global public health
Yager, P., Edwards, T., Fu, E., Helton, K., Nelson, K., Tam, M. R., & Weigl, B. H. (2006) · Nature · doi:10.1038/nature05064 · Cited by 1,979
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
New materials for electrochemical sensing VI: Carbon nanotubes
Merkoçi, A., Pumera, M., Llopis, X., Pérez, B., del Valle, M., & Alegret, S. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.03.019 · Cited by 685
Self-citationRapid tests for sexually transmitted infections (STIs): the way forward
Peeling, R. W., Holmes, K. K., Mabey, D., & Ronald, A. (2006) · Sexually Transmitted Infections · doi:10.1136/sti.2006.024265 · Cited by 599
Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip
Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G. (2009) · Analytical Chemistry · doi:10.1021/ac8024653 · Cited by 344
Wang, L., Chen, W., Xu, D., Shim, B. S., Zhu, Y., Sun, F., Liu, L., Peng, C., Jin, Z., Xu, C., et al. (2009) · Nano Letters · doi:10.1021/nl902368r · Cited by 266
He, Y., Zhang, S., Zhang, X., Baloda, M., Gurung, A. S., Xu, H., Zhang, X., & Liu, G. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.08.079 · Cited by 220
Zou, Z., Du, D., Wang, J., Smith, J. N., Timchalk, C., Li, Y., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac100260m · Cited by 187
New materials for electrochemical sensing V: Nanoparticles for DNA labeling
Merkoçi, A., Aldavert, M., Marı́n, S., & Alegret, S. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.11.007 · Cited by 151
Self-citationImmunosensing using nanoparticles
de la Escosura‐Muñiz, A., Parolo, C., & Merkoçi, A. (2010) · Materials Today · doi:10.1016/s1369-7021(10)70125-5 · Cited by 148
Self-citationA gold nanoparticle-based immunochromatographic assay: The influence of nanoparticulate size
Lou, S., Ye, J.-Y., Li, K.-Q., & Wu, A. (2011) · The Analyst · doi:10.1039/c2an15844b · Cited by 125
Edwards, K. A., & Baeumner, A. J. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0705-x · Cited by 77
Quantitative lateral flow immunosensor using carbon nanotubes as label
Abera, A., & Choi, J. (2010) · Analytical Methods · doi:10.1039/c0ay00412j · Cited by 43
Cited by
Koczula, K. M., & Gallotta, A. (2016) · Essays in Biochemistry · doi:10.1042/ebc20150012 · Cited by 1,147
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Diagnostics for SARS-CoV-2 infections
Kevadiya, B. D., Machhi, J., Herskovitz, J., Oleynikov, M. D., Blomberg, W. R., Bajwa, N., Soni, D., Das, S., Hasan, M., Patel, M., et al. (2021) · Nature Materials · doi:10.1038/s41563-020-00906-z · Cited by 833
Designs, formats and applications of lateral flow assay: A literature review
Sajid, M., Kawde, A.-N., & Daud, M. (2015) · Journal of Saudi Chemical Society · doi:10.1016/j.jscs.2014.09.001 · Cited by 765
Emerging Technologies for Next-Generation Point-of-Care Testing
Vashist, S. K., Luppa, P. B., Yeo, L. Y., Ozcan, A., & Luong, J. H. T. (2015) · Trends in Biotechnology · doi:10.1016/j.tibtech.2015.09.001 · Cited by 705
Metadata
- Authors
- Parolo, C., de la Escosura-Muñiz, A., & Merkoçi, A.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2013-02
- Volume
- 40
- Issue
- 1
- Pages
- 412-416
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2107190439
- Cited by
- 331
- References
- 14
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.