The DOI matches its Crossref record; 114 of the 115 references it cites were found in a registry or an index.
Recent advances in cortisol sensing technologies for point-of-care application
Abstract
Everyday lifestyle related issues are the main cause of psychological stress, which contributes to health disparities experienced by individuals. Prolonged exposure to stress leads to the activation of signaling pathways from the brain that leads to release of cortisol from the adrenal cortex. Various biomarkers have been affected by psychological stress, but cortisol "a steroid hormone" is known as a potential biomarker for its estimation. Cortisol can also be used as a target analyte marker to determine the effect of exposure such as organophosphates on central nervous system, which alters the endocrine system, leading to imbalance in cortisol secretion. Cortisol secretion of individuals depends on day-night cycle and field environment hence its detection at point-of-care (POC) is deemed essential to provide personalized healthcare. Chromatographic techniques have been traditionally used to detect cortisol. The issues relating to assay formation, system complexity, and multistep extraction/purification limits its application in the field. In order to overcome these issues and to make portable and effective miniaturized platform, various immunoassays sensing strategies are being explored. However, electrochemical immunosensing of cortisol is considered as a recent advancement towards POC application. Highly sensitive, label-free and selective cortisol immunosensor based on microelectrodes are being integrated with the microfluidic system for automated diurnal cortisol monitoring useful for personalized healthcare. Although the reported sensing devices for cortisol detection may have a great scope to improve portability, electronic designing, performance of the integrated sensor, data safety and lifetime for point-of-care applications, This review is an attempt to describe the various cortisol sensing platforms and their potential to be integrated into a wearable system for online and continuous monitoring of cortisol rhythm at POC as a function of one's environment.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In addition, since sweat is not sampled but sensed directly on the skin, the skin topography, skin temperature[ 10 ] and pH[ 11 ] may interfere considerably with the measurement results.”
From MicroSweat: A wearable microfluidic patch for noninvasive and reliable sweat collection enables human stress monitoring (2023) · cites this paper as [11]
In the citing paper
“The vents located on top of the storage chambers are <300 µm in diameter to prevent sweat evaporation (based on the Langmuir's free evaporation equation in vacuum[ 11 , 18 ] (see Section S4, Supporting Information) and help preserve the molecular contents of the sweat in the stored fibers.”
From MicroSweat: A wearable microfluidic patch for noninvasive and reliable sweat collection enables human stress monitoring (2023) · cites this paper as [11]
Citations
Cites
Stress and the brain: from adaptation to disease
de Kloet, E. R., Joëls, M., & Holsboer, F. (2005) · Nature Reviews Neuroscience · doi:10.1038/nrn1683 · Cited by 4,621
Biosensors: sense and sensibility
Turner, A. P. F. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35528d · Cited by 1,756
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,518
Electrochemical biosensors: Towards point-of-care cancer diagnostics
Wang, J. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.10.027 · Cited by 1,458
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Russell, E., Koren, G., Rieder, M., & Van Uum, S. (2012) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2011.09.009 · Cited by 1,063
Shankaran, D. R., Gobi, K. V., & Miura, N. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2006.09.014 · Cited by 603
Kirschbaum, C., Tietze, A., Skoluda, N., & Dettenborn, L. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.08.024 · Cited by 584
Measurement of cortisol in human Hair as a biomarker of systemic exposure
Koren, G., Grace Walsh, R. N., Tokmakejian, S., & Uum, S. H. M. V. (2007) · Clinical and investigative medicine · doi:10.25011/cim.v30i5.2894 · Cited by 578
What is stress, and how does it affect reproduction?
Dobson, H., & Smith, R. F. (2000) · Animal Reproduction Science · doi:10.1016/s0378-4320(00)00080-4 · Cited by 549
Flagged first, then by citations
1 of the 115 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Mitchell, 2009, Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection, Analyst (Lond.), 134, 380, 10.1039/B817083P · DOI
Cited by
Sorted by citations
Items 201–300 of 314
Immunosensor for Assessing the Welfare of Trainee Guide Dogs
Perkins, H., Higgins, M., Marcato, M., Galvin, P., & Teixeira, S. R. (2021) · Biosensors · doi:10.3390/bios11090327 · Cited by 11
Cherian, A. R., Keerthana, P., Bhat, V. S., Sirimahachai, U., Varghese, A., & Hegde, G. (2022) · New Journal of Chemistry · doi:10.1039/d2nj03643f · Cited by 11
Organic Thin Film Transistor for Effective Biomarker Detection in Early Disease Diagnosis
Wang, Y., Si, C., Sun, C., & Wang, T. (2023) · Chemosensors · doi:10.3390/chemosensors11030202 · Cited by 11
Smartphone‐Based Sensing of Cortisol by Functionalized Rhodamine Probes
Santonocito, R., Cavallaro, A., Puglisi, R., Pappalardo, A., Tuccitto, N., Petroselli, M., & Sfrazzetto, G. T. (2024) · Chemistry - A European Journal · doi:10.1002/chem.202401201 · Cited by 11
Lab-on-a-chip technologies for genodermatoses: Recent progress and future perspectives
Cui, H., Guo, S., Wenju, W., Li, L., Lulu, W., Linjun, D., Li, J., Ren, X., & Li, B. (2016) · Journal of Dermatological Science · doi:10.1016/j.jdermsci.2016.09.002 · Cited by 11
Effect of Auriculotherapy on Stress: A Systematic Review and Meta-Analysis
Choi, S., & Kim, B. (2024) · Journal of Holistic Nursing · doi:10.1177/08980101241257138 · Cited by 10
Point-of-Care Biosensors for Healthcare Applications
Daurai, B., & Gogoi, M. (2022) · Springer eBooks · doi:10.1007/978-981-19-5141-1_1 · Cited by 10
Kayacan, Y., DEREBASI, D. G., Cihat, U. C. A. R., OZGOCER, T., & YILDIZ, S. (2022) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.21.11811-0 · Cited by 10
NIR-based Sensing System for Non-invasive Detection of Hemoglobin for Point-of-care Applications
Kumar, S., Kumar, Y., Dogra, A., Shaw, V., & Kaushik, A. K. (2021) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405617666210823100316 · Cited by 10
Self-citationAli, H., Yadav, A., & Verma, N. (2021) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2021.108656 · Cited by 10
The effect of stress-induced cortisol increase on the sense of ankle proprioception
Şenol, D. (2019) · Turkish Journal of Physical Medicine and Rehabilitation · doi:10.5606/tftrd.2019.2457 · Cited by 10
DNA super-lattice-based aptasensor for highly sensitive and selective detection of cortisol
Cantelli, L., Paschoalino, W. J., Kogikoski, S., Pessanha, T. M., & Kubota, L. T. (2022) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2022.100228 · Cited by 9
Lipowicz, M., & Garcia, A. (2015) · Bioengineering · doi:10.3390/bioengineering2020122 · Cited by 9
Functionalized nanomaterial- based electrochemical sensors for point-of-care devices
Kaya, H. K., Çağlayan, T., & Kuralay, F. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-823788-5.00021-1 · Cited by 9
Li, J., Chen, Q., Li, W., Li, S., Tan, C. S., Ma, S., Hou, S., Fan, B., & Chen, Z. (2025) · Biosensors · doi:10.3390/bios15030140 · Cited by 8
Microneedle-based wearable sensors: a new frontier in real-time biomarker monitoring
Patil, S. N., Jain, S. N., Patil, S. N., & Bhise, Y. V. (2025) · Drug Development and Industrial Pharmacy · doi:10.1080/03639045.2025.2529437 · Cited by 8
Solution-Phase Electrochemical Aptamer-Based Sensors
Yuan, Y., Bali, A., White, R. J., & Heikenfeld, J. C. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3203026 · Cited by 8
An optical sensing approach for the noninvasive transdermal monitoring of cortisol
Hwang, Y., Gupta, N., Ojha, Y. R., & Cameron, B. D. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2208971 · Cited by 8
The National Emergency Department Overcrowding Scale and Perceived Staff Workload
McKinley, K. W., Bregstein, J. S., Perotte, R., Fenster, D. B., Kwok, M. Y., Rose, J., Nye, M. L., Sonnett, M., & Kessler, D. O. (2024) · Pediatric Emergency Care · doi:10.1097/pec.0000000000003300 · Cited by 7
Cesarean delivery is associated with suppressed activities of the stress axes
Uçar, C., Bülbül, M., & Yıldız, S. (2021) · Stress · doi:10.1080/10253890.2021.2015318 · Cited by 7
Persuasive Technologies and the Right to Mental Liberty
Ligthart, S., Meynen, G., & Douglas, T. A. (2022) · Cambridge University Press eBooks · doi:10.1017/9781108775038.005 · Cited by 7
Xu, K., Yang, J., Shen, L., Wang, X., Hui, N., & Wang, J. (2023) · Microchimica Acta · doi:10.1007/s00604-023-06083-5 · Cited by 7
Ahmed, T., Powner, M. B., Qassem, M., & Kyriacou, P. A. (2024) · Sci · doi:10.3390/sci6020020 · Cited by 7
Yin, X., Ji, X., Liu, W., Li, X., Wang, M., Xin, Q., Zhang, J., Yan, Z., & Song, A. M. (2024) · Lab on a Chip · doi:10.1039/d4lc00247d · Cited by 7
Αναστασίου, Α., Nikaki, A., Pitoglou, S., & Koumpouros, Y. (2022) · International Journal of Reliable and Quality E-Healthcare · doi:10.4018/ijrqeh.297089 · Cited by 7
Uninterrupted real‐time cerebral stress level monitoring using wearable biosensors: A review
Mishra, A., Agrawal, M., Ali, A., & Garg, P. (2023) · Biotechnology and Applied Biochemistry · doi:10.1002/bab.2491 · Cited by 8
Wet chemically produced nanomaterials for soft wearable biosensors
Wang, R., Mao, G., Chu, D., Nasiri, N., Wang, Y., Bilek, M., Yong, K., Wong, W. W. H., Skafidas, S., Liu, J. Z., et al. (2025) · Nanoscale Horizons · doi:10.1039/d5nh00048c · Cited by 6
Wang, Y., Murakami, H., Kasama, T., Mitsuzawa, S., Shinkawa, S., Miyake, R., & Takai, M. (2023) · iScience · doi:10.1016/j.isci.2023.107820 · Cited by 6
Capasso, F., Pitruzzella, R., Tavoletta, I., Perri, C., Zeni, L., Porto, G., Arcadio, F., Chiodi, A., Marzano, C., Renzullo, L. P., et al. (2024) · IEEE Sensors Applications Symposium (SAS) · doi:10.1109/sas60918.2024.10636628 · Cited by 6
Lee, S., Kang, C., Song, J., Kwon, Y., & Kim, J. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343497 · Cited by 6
A Novel Approach of LMR/MIP for Optical Fiber based Salivary Cortisol Sensor
Gupta, B. D., Usha, S. P., & Shrivastav, A. M. (2016) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2016.jtu5a.145 · Cited by 6
Circulatory RNA based non-invasive detection and diagnosis of breast cancer
Barsola, B., Kumari, P., Saklani, S., & Pathania, D. (2022) · Materials Today Proceedings · doi:10.1016/j.matpr.2022.10.206 · Cited by 6
Sonawane, A., Nasim, S., Shah, P., Ramaswamy, S. D., Urizar, G. G., Manickam, P., Mujawar, M. A., & Bhansali, S. (2020) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/aba856 · Cited by 6
Self-citationClegg, S. R., & Millson, S. H. (2021) · Comparative Cognition & Behavior Reviews · doi:10.3819/ccbr.2021.160002 · Cited by 6
Point-of-Care Endocrine Diagnostics
Ehrenkranz, J. R. L. (2017) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2017.04.010 · Cited by 6
All Inkjet Printing Sensor Device on Paper: for Immunosensors Applications
Zea, M., Moya, A., Nemeir, I. A., Gallardo-González, J., Zine, N., Errachid, A., Villa, R., & Gabriel, G. (2019) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2019.8808473 · Cited by 6
Spotts, I., Leclerc, C. A., & Collier, C. M. (2019) · Applied Optics · doi:10.1364/ao.58.007904 · Cited by 6
Microfluidic Line-Free Mass Sensor Based on an Antibody-Modified Mechanical Resonator
Yamaguchi, M. (2018) · Micromachines · doi:10.3390/mi9040177 · Cited by 6
Kaushik, A. K. (2019) · Biosensors · doi:10.3390/bios9030101 · Cited by 6
Self-citationA Simple, sensitive, and selective electrochemical aptasensor for cortisol based on rGO‐AuNPs
da Silva, A. D., Paschoalino, W. J., & Kubota, L. T. (2022) · Electroanalysis · doi:10.1002/elan.202200401 · Cited by 5
Ultraviolet LED based compact and fast cortisol detector with ultra high sensitivity
Sinha, R., Vabbina, P. K., Ahmadivand, A., Karabiyik, M., Gerislioglu, B., & Pala, N. (2016) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2016.7808701 · Cited by 5
Disposable collection kit for rapid and reliable collection of saliva
Yamaguchi, M., Tezuka, Y., Takeda, K., & Shetty, V. (2015) · American Journal of Human Biology · doi:10.1002/ajhb.22696 · Cited by 5
Ashton, R., Rizwan, M., & Gwenin, C. D. (2025) · Sensors and Actuators Reports · doi:10.1016/j.snr.2025.100325 · Cited by 4
Bhanvadiya, H., & Parikh, N. (2026) · Current Pharmaceutical Analysis · doi:10.1016/j.cpan.2025.12.009 · Cited by 4
Mobile sensing to advance tumor modeling in cancer patients: A conceptual framework
Chow, P. I., Roller, D. G., Boukhechba, M., Shaffer, K. M., Ritterband, L. M., Reilley, M. J., Le, T. M., Kunk, P. R., Bauer, T. W., & Gioeli, D. G. (2023) · Internet Interventions · doi:10.1016/j.invent.2023.100644 · Cited by 4
The efficacy of laughter-based interventions in children: A systematic review and meta-analysis
Kim, B., & Choi, S. (2025) · Journal of Child Health Care · doi:10.1177/13674935251346886 · Cited by 4
Semwal, V., Højgaard, J., Møller, E., Bang, O., & Janting, J. (2023) · Photonics · doi:10.3390/photonics10070840 · Cited by 4
Current Trends in the Development of Electrochemical Biosensor for Detecting Analytes from Sweat
Singh, A., Sharma, A., Dubey, A., & Arya, S. K. (2023) · Current Medicinal Chemistry · doi:10.2174/0929867331666230807143639 · Cited by 4
Self-citationSesay, A., Tervo, P., & Tikkanen, E. (2017) · Wiley eBooks · doi:10.1002/9781119065036.ch2
Wu, D., Chen, D. W., Zhang, C., Yao, X., Shao, W., Zhang, Y., Mo, Z., & Liu, Z. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.139954 · Cited by 3
A Smartphone-Based Detection Method of Colloidal Gold Immunochromatographic Strip
Jin, S., Bai, L., Xia, G., Ma, L., Wang, J., Li, Z., & Cai, F. (2021) · Photonics · doi:10.3390/photonics8120576 · Cited by 3
Ramos-Reyes, G. M., Corona‐Avendaño, S., Ramírez-Silva, M. T., Romero-Romo, M., & Palomar-Pardavé, M. (2024) · Journal of Applied Spectroscopy · doi:10.1007/s10812-024-01709-9 · Cited by 3
Nanotechnology-based Detection Strategies for Hypertension Biomarkers
Wang, Z., Zeng, Y., Wang, Y., & Chen, C. (2024) · Chemical Research in Chinese Universities · doi:10.1007/s40242-024-4053-1 · Cited by 3
Sahi, A. K., Varshney, N., Sidu, R. K., Poddar, S., Pallawi, Singh, K., & Mahto, S. K. (2020) · Springer eBooks · doi:10.1007/978-981-15-5823-8_11 · Cited by 3
Pen-Type Electrodermal Activity Sensing System for Stress Detection Based on Likelihood Ratios
Lee, T., Natarajan, B., & Warren, S. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3132176 · Cited by 3
Kumar, J. V., Shylashree, N., Hebbar, S., Sriniketh, S. S., Kotian, S. A., Mohanram, S., Sridhar, V. G., Khosla, A., & Channegowda, M. (2024) · BioNanoScience · doi:10.1007/s12668-024-01357-5 · Cited by 3
Duplicate Analysis of Cortisol for Stress Check Using QCM with a Self–suction Flow System
Ito, T., Aoki, N., Shinobu, W., & Suzuki, K. (2014) · Procedia Engineering · doi:10.1016/j.proeng.2014.11.666 · Cited by 3
Sonochemical Synthesis of Zinc Oxide Nanostructures for Sensing and Energy Harvesting
Vabbina, P. K. (2016) · doi:10.25148/etd.fidc000787 · Cited by 3
Pen-type electrodermal activity sensing system for stress detection based on likelihood ratios
Lee, T. (2020) · K-State Research Exchange (Kansas State University) · Cited by 3
Biosensors for Salivary Biomarker Detection of Cancer and Neurodegenerative Diseases
Sajeevan, B., Gopika, M. G., Sreelekshmi, S., Rejithamol, R., Antherjanam, S., & Saraswathyamma, B. (2023) · Wiley eBooks · doi:10.1002/9781394167135.ch11 · Cited by 3
Cortisol as a stress biomarker: analytical perspectives and challenges
Suryawanshi, R., & Sharma, S. (2026) · Clinica Chimica Acta · doi:10.1016/j.cca.2026.121008 · Cited by 2
Baroroh, U., Setiani, N. A., Mardiah, I., Astriany, D., & Yusuf, M. (2022) · Indonesian Journal of Chemistry · doi:10.22146/ijc.71480 · Cited by 2
A Review on Nanomaterial-based Point-of-care Devices: Emphasis on Cardiovascular Diseases
Chokkareddy, R., Bathinapatla, A., Azeez, A., Kanchi, S., & Redhi, G. G. (2024) · Current Analytical Chemistry · doi:10.2174/0115734110287874240629095513 · Cited by 2
Kim, T., Uddin, M. A., Yi, Q., & Esfandyarpour, R. (2024) · IEEE BioSensors Conference (BioSensors) · doi:10.1109/biosensors61405.2024.10712684 · Cited by 2
A Thin Film Coil with Integrated Electrochemical Sensor for Wireless and Passive Biomarker Sensing
Chen, R., Baldwin, A., Ramirez, E., & Meng, E. F. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917430 · Cited by 2
Hernández-Garcés, P., Arredondo, M., Cruces, R. N. P., Ramírez, J. A. C., Acevedo, R., Olvera, X., Romero, D., & Batina, N. (2025) · Microfluidics and Nanofluidics · doi:10.1007/s10404-025-02836-1 · Cited by 3
Portable Electrochemical Detection System Design Based on LMP91000
Li, Y., Zhang, C., Wang, Y., Xu, X., Zhang, W. Z., Zhang, Z., & Li, Y. (2024) · International Conference on Mechatronics and Computer Technology Engineering (MCTE) · doi:10.1109/mcte62870.2024.11117822 · Cited by 2
Pinkney, S., Bains, S., Goyal, A., Gupta, N., & Bolodeoku, J. (2017) · Annals of Clinical and Laboratory Research · doi:10.21767/2386-5180.1000196 · Cited by 2
Ulu, A., & Ateş, B. (2021) · Royal Society of Chemistry eBooks · doi:10.1039/9781839162756-00454 · Cited by 1
Paper-Based Microanalytical Device for Colorimetric Detection of Stress in Human Saliva Sample
Hernández-Garcés, P., & Batina, N. (2022) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-031-18256-3_59 · Cited by 1
Biosensors and Biomarkers for the Detection of Motion Sickness
Wang, Y., Liu, C., Zhao, W., Wang, Q., Sun, X., & Zhang, S. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202403606 · Cited by 1
A Sweat Cortisol Sensor Based on Gold-Modified Molecularly Imprinted Polymer
Liu, Z., Xie, G., Li, J., Yuan, H. C., & Su, Y. (2025) · Nanomaterials · doi:10.3390/nano15211654 · Cited by 1
A Portable Microfluidic Paper-Based Analytical Device for Sensing of Cortisol in Artificial Saliva
Wankhade, U., Khan, D., Mahule, K., Patle, M. A., Ambadkar, M. A., Wele, I., Kalambe, J. P., & Pande, R. S. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3645422 · Cited by 1
Wearable Sweat Sensors for Personalised Healthcare
Nagarkoti, S. K., Yadav, R., & Bhati, P. (2025) · International Conference on Emerging Trends in Networks and Computer Communications (ETNCC) · doi:10.1109/etncc66224.2025.11299613 · Cited by 1
PEGDA hydrogel-based biosensor for continuous salivary cortisol monitoring without pre-treatment
Lee, S., Cho, E., Song, J., Ramakrishnan, N., Shin, D., Kwon, Y., & Kim, J. (2026) · Talanta · doi:10.1016/j.talanta.2026.129518 · Cited by 1
Chen, R., Baldwin, A., Gong, Y., Ramirez, E., Amirghasemi, F., Liang, J., & Meng, E. F. (2026) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2026.139813 · Cited by 1
Electrochemical (Bio) Sensing of Amyloid Beta Peptide (Aβ) using Metallic Nanoparticles
Karastogiann, S. (2020) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2020.32.005274 · Cited by 1
Materials and Surfaces in Microfluidic Biosensors
Manickam, P., Nelson, J., & Bhansali, S. (2016) · Springer eBooks · doi:10.1007/978-3-319-40036-5_6 · Cited by 1
Self-citation1 Nanobiotechnology: An Abrupt Merger
Pasha, S. K., Jalal, A. H., Singh, A., & Bhansali, S. (2016) · doi:10.1201/9781315366425-2 · Cited by 1
Self-citationElectrochemical Non-Enzymatic Biosensing of Cortisol Using ZnO-Graphene Nanocomposite
Loganathan, H., Durgalakshmi, D., & Rajendran, A. R. (2025) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/adb912 · Cited by 1
Electrochemical affinity biosensors for hormones and related biomarkers
Yáñez‐Sedeño, P., Campuzano, S., & Pingarrón, J. M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818592-6.00003-7 · Cited by 1
Towards an Online Polymer Optical Fiber Cortisol Sensor for Aquaculture
Janting, J., & Inglev, R. (2021) · International Conference on Optical Fiber Sensors (OFS) · doi:10.1364/ofs.2020.th4.51 · Cited by 1
Garcés, P. H. (2015) · doi:10.24275/uami.5q47rp016 · Cited by 1
An examination of worry as a mediator of the effect of stress on somatic health and cognition
Quade, T. (2016) · UVic’s Research and Learning Repository (University of Victoria)
Visual Presentation Method of Stress Evidence Paper in Conjunction with Web Article
Yamaguchi, M., & Ohmukai, I. (2017) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.137.310
Development of Saliva-based Cortisol Biosensors Using Smartphone-based Image Analysis
Nino-Esparza, R., Riveroll, A. L., McDuffee, L. A., Montelpare, W. J., & Ahmadi, A. (2018) · CMBES Proceedings
Keskin, E. (2019) · Konya Journal of Engineering Sciences · doi:10.15317/scitech.2019.210
Wan, C. (2019) · uO Research (University of Ottawa) · doi:10.20381/ruor-23821
Measurement in biological fluids
Patel, B. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-821203-5.00002-6
Biomedical Application of Interdigital Sensors
Afsarimanesh, N., Sabet, G. S., & Mukhopadhyay, S. C. (2021) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-030-62684-6_9
Asif, S. (2020) · Universiti Sains Malaysia Institutional Repository (Universiti Sains Malaysia)
Effects of Prenatal Education and Type Of Delivery On Stress Axes
Uçar, C., Bülbül, M., & Yıldız, S. (2021) · Harran Üniversitesi Tıp Fakültesi Dergisi · doi:10.35440/hutfd.1005965
Wang, Y., Murakami, H., Kasama, T., Mitsuzawa, S., Shinkawa, S., Miyake, R., & Takai, M. (2022) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors52175.2022.9967171
Localized Surface Plasmon Resonance based Polymer Optical Fiber Cortisol Aptasensor for Aquaculture
Janting, J., & Semwal, V. (2022) · International Conference on Optical Fiber Sensors (OFS) · doi:10.1364/ofs.2022.w4.50
Title: Correlation between salivary cortisol and anxiety in recurrent aphthous stomatitis
Shirzaiy, M. (2023) · Res Dent Sci · doi:10.52547/jrds.20.1.41
Quantitative analysis of steroids
Honour, J. W. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-818124-9.00010-3
On Stimulating Fungi Pleurotus Ostreatus with Hydrocortisone
Dehshibi, M. M., Chiolerio, A., Nikolaidou, A. E., Mayne, R., Gandía, A., Ashtari-Majlan, M., & Adamatzky, A. (2023) · Emergence, complexity and computation · doi:10.1007/978-3-031-38336-6_9
The Use of Electrical Impedance Spectroscopy for Medical Application: A Mini Review
El Asri, S. (2023) · Physical Science & Biophysics Journal · doi:10.23880/psbj-16000250
Bolodeoku, J., & Kim, T. K. (2023) · IntechOpen eBooks · doi:10.5772/intechopen.1003657
Metadata
- Authors
- Kaushik, A., Vasudev, A., Arya, S. K., Pasha, S. K., & Bhansali, S.
- Affiliations
- Florida International University (US)
- Agency for Science, Technology and Research (SG)
- Corresponding author
- Kaushik, Ajeet
- Bhansali, Shekhar
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 53
- Pages
- 499-512
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2013008702
- Cited by
- 316
- References
- 115
- Citations by year
- 2026: 13 · 2025: 23 · 2024: 30 · 2023: 31 · 2022: 35 · 2021: 33 · 2020: 36 · 2019: 21 · 2018: 24 · 2017: 18 · 2016: 31 · 2015: 12 · 2014: 8
- FWCI
- 1.20
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- Forensic Sciences Foundation
- National Institute of Mental Health (R44MH085474)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Keywords
- cortisol detection, point-of-care testing, electrochemical immunosensor, microelectrodes, microfluidics, wearable sensors, diurnal cortisol rhythm, organophosphate exposure, personalized healthcare, label-free detection
- MeSH terms
- Humans, Hydrocortisone, Immunoassay, Biosensing Techniques, Point-of-Care Systems, Microfluidics, Precision Medicine
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review