The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
A simple and compact smartphone accessory for quantitative chemiluminescence-based lateral flow immunoassay for salivary cortisol detection
Open accessAbstract
We have developed a simple and accurate biosensor based on a chemiluminescent (CL)-lateral flow immunoassay (LFIA) method integrated in a smartphone to quantitatively detect salivary cortisol. The biosensor is based on a direct competitive immunoassay using peroxidase-cortisol conjugate, detected by adding the chemiluminescent substrate luminol/enhancer/hydrogen peroxide. The smartphone camera is used as light detector, for image acquisition and data handling via a specific application. We 3D-printed simple accessories to adapt the smartphone. The system comprises a cartridge, which houses the LFIA strip, and a smartphone adaptor with a plano-convex lens and a cartridge-insertion slot. This provides a mini-darkbox and aligned optical interface between the camera and the LFIA membrane for acquiring CL signals. The method is simple and fast, with a detection limit of 0.3 ng/mL. It provides quantitative analysis in the range of 0.3-60 ng/mL, which is adequate for detecting salivary cortisol in the clinically accepted range. It could thus find application in the growing area of home-self-diagnostic device technology for clinical biomarker monitoring, overcoming the current difficulties in achieving sensitive and quantitative information with conventional systems taking the advantage of smartphone connectivity and the enhanced performance of the included camera.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because saliva can be readily collected123-125, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms,126-134.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [130]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2009) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,720
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Posthuma‐Trumpie, G. A., Korf, J., & van Amerongen, A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,588
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,445
The Smartphone in Medicine: A Review of Current and Potential Use Among Physicians and Students
Ozdalga, E., Ozdalga, A., & Ahuja, N. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.1994 · Cited by 654
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 426
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Özcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40864c · Cited by 365
Zhao, W., & van den Berg, A. (2008) · Lab on a Chip · doi:10.1039/b814043j · Cited by 237
Significantly Improved Analytical Sensitivity of Lateral Flow Immunoassays by Using Thermal Contrast
Qin, Z., Chan, W. C. W., Boulware, D. R., Akkin, T., Butler, E. K., & Bischof, J. C. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200997 · Cited by 221
A conductometric biosensor for biosecurity
Muhammad-Tahir, Z., & Alocilja, E. C. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00020-4 · Cited by 220
Paper based point-of-care testing disc for multiplex whole cell bacteria analysis
Li, C.-Z., Vandenberg, K. N., Prabhulkar, S., Zhu, X., Schneper, L. M., Mathee, K., Rosser, C. J., & Almeide, E. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.035 · Cited by 218
Zou, Z., Du, D., Wang, J., Smith, J. N., Timchalk, C. A., Li, Y., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac100260m · Cited by 187
Patterned paper and alternative materials as substrates for low-cost microfluidic diagnostics
Ballerini, D. R., Li, X., & Shen, W. (2012) · Microfluidics and Nanofluidics · doi:10.1007/s10404-012-0999-2 · Cited by 164
Peer Reviewed: Analytical Bioluminescence and Chemiluminescence
Roda, A., Guardigli, M., Michelini, E., Mirasoli, M., & Pasini, P. (2003) · Analytical Chemistry · doi:10.1021/ac031398v · Cited by 132
Self-citationFernández‐Sánchez, C., McNeil, C. J., Rawson, K., & Nilsson, O. (2004) · Analytical Chemistry · doi:10.1021/ac0494937 · Cited by 129
Lateral Flow Immunoassay Using Europium Chelate-Loaded Silica Nanoparticles as Labels
Xia, X., Xu, Y., Zhao, X., & Li, Q. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.114561 · Cited by 122
Label-free, chemiresistor immunosensor for stress biomarker cortisol in saliva
Tlili, C., Myung, N. V., Shetty, V., & Mulchandani, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.04.045 · Cited by 117
Lee, S., Kim, G., & Moon, J.-H. (2013) · Sensors · doi:10.3390/s130405109 · Cited by 114
Wang, X., Hofmann, O., Das, R., Barrett, E. M., deMello, A. J., de Mello, J. C., & Bradley, D. D. C. (2006) · Lab on a Chip · doi:10.1039/b611067c · Cited by 103
Plastic ELISA-on-a-Chip Based on Sequential Cross-Flow Chromatography
Cho, J., Han, S.-M., Paek, E.-H., Cho, I.-H., & Paek, S. (2006) · Analytical Chemistry · doi:10.1021/ac051453v · Cited by 102
A portable bioluminescence engineered cell-based biosensor for on-site applications
Roda, A., Cevenini, L., Michelini, E., & Branchini, B. R. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.02.022 · Cited by 96
Self-citationDevelopment and application of a quantitative lateral flow immunoassay for fumonisins in maize
Anfossi, L., Calderara, M., Baggiani, C., Giovannoli, C., Arletti, E., & Giraudi, G. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.09.045 · Cited by 91
Self-citationRoda, A., Mirasoli, M., Dolci, L. S., Buragina, A., Bonvicini, F., Simoni, P., & Guardigli, M. (2011) · Analytical Chemistry · doi:10.1021/ac200360k · Cited by 85
Self-citationA rapid lateral flow test for the determination of total type B fumonisins in maize
Molinelli, A., Grossalber, K., & Krska, R. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-009-3082-4 · Cited by 84
Chemiluminescence-based biosensor for fumonisins quantitative detection in maize samples
Mirasoli, M., Buragina, A., Dolci, L. S., Simoni, P., Anfossi, L., Giraudi, G., & Roda, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.11.039 · Cited by 77
Self-citationMarzocchi, E., Grilli, S., Ciana, L. D., Prodi, L., Mirasoli, M., & Roda, A. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.03.020 · Cited by 77
Self-citationMirasoli, M., Buragina, A., Dolci, L. S., Guardigli, M., Simoni, P., Montoya, Á., Maiolini, E., Girotti, S., & Roda, A. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.01.036 · Cited by 74
Self-citationRoda, A., Pasini, P., Musiani, M., Girotti, S., Baraldini, M., Carrea, G., & Suozzi, A. (1996) · Analytical Chemistry · doi:10.1021/ac951062o · Cited by 66
Self-citationChemiluminescent methods for detecting and quantitating enzyme activity
Kricka, L. J., Voyta, J. C., & Bronstein, I. (2000) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(00)05500-2 · Cited by 57
Microfluidic Chip With Integrated a-Si:H Photodiodes for Chemiluminescence-Based Bioassays
Caputo, D., de Cesare, G., Dolci, L. S., Mirasoli, M., Nascetti, A., Roda, A., & Scipinotti, R. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2256889 · Cited by 39
Self-citationSalter, R. S., Fitchen, J., Collaborators:, Bain, B., Bella, M., Bergman, S., Biotelle, A. C., Bulthaus, M., Butterworth, F., Collins, P., et al. (2006) · Journal of AOAC International · doi:10.1093/jaoac/89.4.1061 · Cited by 35
Development of a sensitive enzyme immunoassay for plasma and salivary steroids
Roda, A., Girotti, S., Lodi, S., & Preti, S. C. (1984) · Talanta · doi:10.1016/0039-9140(84)80218-0 · Cited by 34
Self-citationRoda, A., Mirasoli, M., Venturoli, S., Cricca, M., Bonvicini, F., Baraldini, M., Pasini, P., Zerbini, M., & Musiani, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.10.1654 · Cited by 33
Self-citationSalter, R. S., Douglas, D., Tess, M. E., Markovsky, B., & Saul, S. J. (2006) · PubMed · Cited by 29
Research works printed but not linked: 2
- Pires, 2014, Biomed. Mater. Eng., 24, 15
- Swain, 2008, Photon Spectra, 42, 46
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 651
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Özer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 638
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 601
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Parolo, C., Sena‐Torralba, A., Bergua, J. F., Calucho, E., Fuentes‐Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0357-x · Cited by 584
Metadata
- Authors
- Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A.
- Affiliations
- University of Bologna (IT)
- University of Turin (IT)
- Corresponding author
- Roda, Aldo
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 64
- Pages
- 63-68
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2080173526
- Cited by
- 373
- References
- 35
- Citations by year
- 2026: 10 · 2025: 26 · 2024: 27 · 2023: 23 · 2022: 30 · 2021: 37 · 2020: 38 · 2019: 42 · 2018: 44 · 2017: 32 · 2016: 41 · 2015: 23
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Institutional Research Information System University of Turin (University of Turin) (submittedVersion, other-oa)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- salivary cortisol, chemiluminescence, lateral flow immunoassay, smartphone biosensors, luminol, competitive immunoassay
- MeSH terms
- Equipment Design, Humans, Hydrocortisone, Immunoassay, Luminescent Measurements, Saliva, Biosensing Techniques, Point-of-Care Systems, Cell Phone, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review