The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
A simple and compact smartphone accessory for quantitative chemiluminescence-based lateral flow immunoassay for salivary cortisol detection
Open accessAbstract
We have developed a simple and accurate biosensor based on a chemiluminescent (CL)-lateral flow immunoassay (LFIA) method integrated in a smartphone to quantitatively detect salivary cortisol. The biosensor is based on a direct competitive immunoassay using peroxidase-cortisol conjugate, detected by adding the chemiluminescent substrate luminol/enhancer/hydrogen peroxide. The smartphone camera is used as light detector, for image acquisition and data handling via a specific application. We 3D-printed simple accessories to adapt the smartphone. The system comprises a cartridge, which houses the LFIA strip, and a smartphone adaptor with a plano-convex lens and a cartridge-insertion slot. This provides a mini-darkbox and aligned optical interface between the camera and the LFIA membrane for acquiring CL signals. The method is simple and fast, with a detection limit of 0.3 ng/mL. It provides quantitative analysis in the range of 0.3-60 ng/mL, which is adequate for detecting salivary cortisol in the clinically accepted range. It could thus find application in the growing area of home-self-diagnostic device technology for clinical biomarker monitoring, overcoming the current difficulties in achieving sensitive and quantitative information with conventional systems taking the advantage of smartphone connectivity and the enhanced performance of the included camera.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Because saliva can be readily collected123-125, it has been used in connection to in vitro diagnostic biosensors on strips or portable device platforms,126-134.”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [130]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostics for the Developing World: Microfluidic Paper-Based Analytical Devices
Martinez, A. W., Phillips, S. T., Whitesides, G. M., & Carrilho, E. (2009) · Analytical Chemistry · doi:10.1021/ac9013989 · Cited by 2,720
Salivary cortisol as a biomarker in stress research
Hellhammer, D. H., Wüst, S., & Kudielka, B. M. (2009) · Psychoneuroendocrinology · doi:10.1016/j.psyneuen.2008.10.026 · Cited by 1,925
Posthuma‐Trumpie, G. A., Korf, J., & van Amerongen, A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,588
Martinez, A. W., Phillips, S. T., Carrilho, E., Thomas, S. W., Sindi, H., & Whitesides, G. M. (2008) · Analytical Chemistry · doi:10.1021/ac800112r · Cited by 1,445
The Smartphone in Medicine: A Review of Current and Potential Use Among Physicians and Students
Ozdalga, E., Ozdalga, A., & Ahuja, N. (2012) · Journal of Medical Internet Research · doi:10.2196/jmir.1994 · Cited by 654
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 426
Integrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Özcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40864c · Cited by 365
Zhao, W., & van den Berg, A. (2008) · Lab on a Chip · doi:10.1039/b814043j · Cited by 237
Significantly Improved Analytical Sensitivity of Lateral Flow Immunoassays by Using Thermal Contrast
Qin, Z., Chan, W. C. W., Boulware, D. R., Akkin, T., Butler, E. K., & Bischof, J. C. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200997 · Cited by 221
Research works printed but not linked: 2
- Pires, 2014, Biomed. Mater. Eng., 24, 15
- Swain, 2008, Photon Spectra, 42, 46
Cited by
Sorted by citations
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Biosensors and bioelectronics on smartphone for portable biochemical detection
Zhang, D., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.037 · Cited by 651
Microfluidic Paper-Based Analytical Devices: From Design to Applications
Noviana, E., Özer, T., Carrell, C. S., Link, J. S., McMahon, C., Jang, I., & Henry, C. S. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01335 · Cited by 638
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 601
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Parolo, C., Sena‐Torralba, A., Bergua, J. F., Calucho, E., Fuentes‐Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., et al. (2020) · Nature Protocols · doi:10.1038/s41596-020-0357-x · Cited by 584
Smartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Self-citationReview on microfluidic paper-based analytical devices towards commercialisation
Akyazi, T., Basabe‐Desmonts, L., & Benito‐Lopez, F. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.11.010 · Cited by 534
Paper-Based Microfluidic Devices: Emerging Themes and Applications
Yang, Y., Noviana, E., Nguyen, M., Geiss, B. J., Dandy, D. S., & Henry, C. S. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04581 · Cited by 509
Shrivastava, S., Trung, T. Q., & Lee, N. (2020) · Chemical Society Reviews · doi:10.1039/c9cs00319c · Cited by 500
Photonic crystals: emerging biosensors and their promise for point-of-care applications
Inan, H., Poyraz, M., İnci, F., Lifson, M. A., Baday, M., Cunningham, B. T., & Demirci, U. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00206d · Cited by 490
Nardo, F. D., Chiarello, M., Cavalera, S., Baggiani, C., & Anfossi, L. (2021) · Sensors · doi:10.3390/s21155185 · Cited by 433
Self-citationRecent advances in high-sensitivity detection methods for paper-based lateral-flow assay
Nguyen, V.-T., Song, S., Park, S., & Joo, C. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112015 · Cited by 375
Additive manufacturing of medical instruments: A state-of-the-art review
Culmone, C., Smit, G., & Breedveld, P. (2019) · Additive manufacturing · doi:10.1016/j.addma.2019.03.015 · Cited by 372
Zheng, L., Cai, G., Wang, S., Liao, M., Li, Y., & Lin, J. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.006 · Cited by 335
Portable biosensing devices for point-of-care diagnostics: Recent developments and applications
Zarei, M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.04.001 · Cited by 330
Gaudin, V. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.12.005 · Cited by 325
Stress Biomarkers in Biological Fluids and Their Point-of-Use Detection
Steckl, A. J., & Ray, P. (2018) · ACS Sensors · doi:10.1021/acssensors.8b00726 · Cited by 319
Smartphone based bioanalytical and diagnosis applications: A review
Kanchi, S., Sabela, M. I., Mdluli, P. S., Inamuddin, I., & Bisetty, K. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.021 · Cited by 288
Mobile phone-based biosensing: An emerging “diagnostic and communication” technology
Quesada-González, D., & Merkoçi, A. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.062 · Cited by 271
Automatic smartphone-based microfluidic biosensor system at the point of care
Xu, D., Huang, X., Guo, J., & Ma, X. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.03.018 · Cited by 264
Surface plasmon resonance technology: Recent advances, applications and experimental cases
Capelli, D., Scognamiglio, V., & Montanari, R. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.117079 · Cited by 242
Collaborative Sensing in Internet of Things: A Comprehensive Survey
He, S., Shi, K., Liu, C., Guo, B., Chen, J., & Shi, Z. (2022) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2022.3187138 · Cited by 238
Paper-based point-of-care immunoassays: Recent advances and emerging trends
Li, F., You, M., Li, S., Hu, J., Liu, C., Gong, Y. M., Yang, H., & Xu, F. (2019) · Biotechnology Advances · doi:10.1016/j.biotechadv.2019.107442 · Cited by 230
Progress in chemical luminescence-based biosensors: A critical review
Roda, A., Mirasoli, M., Michelini, E., Fusco, M. D., Zangheri, M., Cevenini, L., Roda, B., & Simoni, P. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.06.017 · Cited by 223
Self-citationRecent approaches for optical smartphone sensing in resource-limited settings: a brief review
McCracken, K. E., & Yoon, J. (2016) · Analytical Methods · doi:10.1039/c6ay01575a · Cited by 217
Smartphone‐based clinical diagnostics: towards democratization of evidence‐based health care
Hernández-Neuta, I., Neumann, F., Brightmeyer, J., Tis, T. B., Madaboosi, N., Wei, Q., Özcan, A., & Nilsson, M. F. (2018) · Journal of Internal Medicine · doi:10.1111/joim.12820 · Cited by 207
Towards Lateral Flow Quantitative Assays: Detection Approaches
Urusov, A. Е., Zherdev, A. V., & Dzantiev, B. B. (2019) · Biosensors · doi:10.3390/bios9030089 · Cited by 202
Brangel, P., Sobarzo, A., Parolo, C., Miller, B. S., Howes, P. D., Gelkop, S., Lutwama, J. J., Dye, J. M., McKendry, R. A., Lobel, L. I., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07021 · Cited by 203
Lateral and Vertical Flow Assays for Point‐of‐Care Diagnostics
Jiang, N., Ahmed, R., Damayantharan, M., Ünal, B., Butt, H., & Yetisen, A. K. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900244 · Cited by 201
Roda, A., Cavalera, S., Nardo, F. D., Calabria, D., Rosati, S., Simoni, P., Colitti, B., Baggiani, C., Roda, M., & Anfossi, L. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112765 · Cited by 197
Self-citationRong, Z., Wang, Q., Sun, N., Jia, X., Wang, K., Xiao, R., & Wang, S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.12.043 · Cited by 185
Wang, S., Zheng, L., Cai, G., Liu, N., Liao, M., Li, Y., Zhang, X., & Lin, J. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111333 · Cited by 180
Point-of-care testing: applications of 3D printing
Chan, H. N., Tan, M. J. A., & Wu, H. (2017) · Lab on a Chip · doi:10.1039/c7lc00397h · Cited by 174
Research progress on chemiluminescence immunoassay combined with novel technologies
Xiao, Q., & Xu, C. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115780 · Cited by 166
Barcoded point-of-care bioassays
Yang, M., Liu, Y., & Jiang, X. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00303c · Cited by 162
Application of smartphone-based spectroscopy to biosample analysis: A review
Chen, W., Yao, Y., Chen, T., Shen, W., Tang, S. N., & Lee, H. K. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112788 · Cited by 154
Hu, J., Cui, X., Gong, Y. M., Xu, X., Gao, B., Wen, T., Lu, T. J., & Xu, F. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2016.02.008 · Cited by 158
Signal amplification strategies for paper-based analytical devices
Liu, L., Yang, D., & Liu, G. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.043 · Cited by 151
Aptamer-Based Lateral Flow Biosensor for Rapid Detection of Salivary Cortisol
Dalirirad, S., Han, D., & Steckl, A. J. (2020) · ACS Omega · doi:10.1021/acsomega.0c03223 · Cited by 154
Paper based microfluidic devices: a review of fabrication techniques and applications
Anushka, A., Bandopadhyay, A., & Das, P. K. (2022) · The European Physical Journal Special Topics · doi:10.1140/epjs/s11734-022-00727-y · Cited by 150
Integrated Devices for Non‐Invasive Diagnostics
Ates, H. C., Brunauer, A., von Stetten, F., Urban, G. A., Güder, F., Merkoçi, A., Früh, S. M., & Dincer, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010388 · Cited by 152
Quantifying colorimetric tests using a smartphone app based on machine learning classifiers
Solmaz, M. E., Mutlu, A. Y., Alankuş, G., Kılıç, V., Bayram, A., & Horzum, N. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.08.220 · Cited by 146
Zhao, Y., Yang, M., Fu, Q., Ouyang, H. X., Wen, W., Song, Y., Zhu, C., Lin, Y., & Du, D. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00837 · Cited by 144
Smartphone based non-invasive salivary glucose biosensor
Soni, A., & Jha, S. K. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.10.003 · Cited by 143
Zhang, D., Jiang, J., Chen, J., Zhang, Q. Y., Lu, Y., Yao, Y., Li, S., Liu, G. L., & Liu, Q. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.03.004 · Cited by 141
Colorimetric analyzer based on mobile phone camera for determination of available phosphorus in soil
Moonrungsee, N., Pencharee, S., & Jakmunee, J. (2015) · Talanta · doi:10.1016/j.talanta.2015.01.024 · Cited by 138
Saliva Liquid Biopsy for Point-of-Care Applications
Aro, K. L. S., Fang, W., Wong, D. T., & Tu, M. K. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00077 · Cited by 137
Wang, P., & Kricka, L. J. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2018.287052 · Cited by 134
Enhancing the analytical performance of paper lateral flow assays: From chemistry to engineering
Shirshahi, V., & Liu, G. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116200 · Cited by 131
Lateral Flow Immunoassays – from Paper Strip to Smartphone Technology
Eltzov, E., Guttel, S., Kei, A. L. Y., Sinawang, P. D., Ionescu, R. E., & Marks, R. S. (2015) · Electroanalysis · doi:10.1002/elan.201500237 · Cited by 123
A Self-Contained Chemiluminescent Lateral Flow Assay for Point-of-Care Testing
Deng, J., Yang, M., Wu, J., Zhang, W., & Jiang, X. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b01543 · Cited by 124
Huang, Y., Xu, T., Wang, W., Wen, Y., Li, K., Qian, L., Zhang, X., & Liu, G. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3822-x · Cited by 123
Smart biosensors and intelligent devices for salivary biomarker detection
Zheng, X., Zhang, F., Wang, K., Zhang, W., Li, Y., Sun, Y. L., Sun, X., Li, C., Dong, B., Wang, L., et al. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116281 · Cited by 126
Point of care sensing and biosensing using ambient light sensor of smartphone: Critical review
Dutta, S. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.11.014 · Cited by 121
Electrochemical sensors for cortisol detections: Almost there
Zea, M., Bellagambi, F. G., Halima, H. B., Zine, N., Jaffrezic-Renault, N. J., Villa, R., Gabriel, G., & Errachid, A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116058 · Cited by 122
Lipopolysaccharides detection on a grating-coupled surface plasmon resonance smartphone biosensor
Zhang, J., Khan, I., Zhang, Q., Liu, X., Dostálek, J., Liedberg, B., & Wang, Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.048 · Cited by 115
Kim, K., Kashefi‐Kheyrabadi, L., Joung, Y., Kim, K., Dang, H., Chavan, S. G., Lee, M., & Choo, J. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.129214 · Cited by 118
Jia, M., Chew, W. M., Feinstein, Y., Skeath, P., & Sternberg, E. M. (2016) · The Analyst · doi:10.1039/c5an02387d · Cited by 113
Chen, Y., Sun, J., Xianyu, Y., Yin, B., Niu, Y., Wang, S., Cao, F., Zhang, X., Wang, Y., & Jiang, X. (2016) · Nanoscale · doi:10.1039/c6nr04017a · Cited by 112
3D-Printed Biosensor Arrays for Medical Diagnostics
Sharafeldin, M., Jones, A. L., & Rusling, J. F. (2018) · Micromachines · doi:10.3390/mi9080394 · Cited by 112
Mughairy, B. A., & Lawati, H. A. J. A. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115802 · Cited by 109
Smartphone based LSPR sensing platform for bio-conjugation detection and quantification
Dutta, S., Saikia, K., & Nath, P. (2016) · RSC Advances · doi:10.1039/c6ra01113f · Cited by 107
Zeinhom, M. M. A., Wang, Y., Song, Y., Zhu, M. J., Lin, Y., & Du, D. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.08.002 · Cited by 107
Recent advances in electrochemiluminescence devices for point-of-care testing
Gao, W., Saqib, M., Qi, L., Zhang, W. Y., & Xu, G. (2017) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2017.03.003 · Cited by 103
Kordasht, H. K., Hasanzadeh, M., & Seidi, F. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116455 · Cited by 102
Ye, H., Liu, Y., Zhan, L., Liu, Y., & Qin, Z. (2020) · Theranostics · doi:10.7150/thno.44298 · Cited by 101
Paper-based optical nanosensors – A review
Ghasemi, F., Fahimi-Kashani, N., Bigdeli, A., Alshatteri, A. H., Abbasi-Moayed, S., Al‐Jaf, S. H., Merry, M. Y., Omer, K. M., & Hormozi-Nezhad, M. R. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340640 · Cited by 101
Jo, S., Lee, W., Park, J., Kim, W., Kim, W., Lee, G., Lee, H., Hong, J., & Park, J. (2019) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2019.127424 · Cited by 98
Montali, L., Calabretta, M. M., Lopreside, A., D’Elia, M., Guardigli, M., & Michelini, E. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112232 · Cited by 103
Vignesh, V., Dominguez, B. C., James, T. D., Turner‐Cobb, J. M., Lightman, S. L., & Reis, N. M. (2024) · ACS Sensors · doi:10.1021/acssensors.3c01912 · Cited by 102
Biosensors-on-chip: a topical review
Chen, S., & Shamsi, M. H. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa7117 · Cited by 100
3-D printed adjustable microelectrode arrays for electrochemical sensing and biosensing
Yang, H., Rahman, M. T., Du, D., Panat, R. P., & Lin, Y. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.02.113 · Cited by 94
Kaneta, T., Alahmad, W., & Varanusupakul, P. (2018) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1457045 · Cited by 93
Lateral flow assays for hormone detection
Khelifa, L., Hu, Y., Jiang, N., & Yetisen, A. K. (2022) · Lab on a Chip · doi:10.1039/d1lc00960e · Cited by 93
Smartphone-based low light detection for bioluminescence application
Kim, H., Jung, Y., Doh, I., Lozano-Mahecha, R. A., Applegate, B. M., & Bae, E. (2017) · Scientific Reports · doi:10.1038/srep40203 · Cited by 92
Quantitative Lateral Flow Assays for Salivary Biomarker Assessment: A Review
Miočević, O., Cole, C. R., Laughlin, M. J., Buck, R. L., Slowey, P. D., & Shirtcliff, E. A. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00133 · Cited by 94
Current methods for stress marker detection in saliva
Giacomello, G., Scholten, A., & Parr, M. K. (2020) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113604 · Cited by 99
Moonla, C., Lee, D. H., Rokaya, D., Rasitanon, N., Kathayat, G., Lee, W.-Y., Kim, J., & Jeerapan, I. (2022) · ECS Sensors Plus · doi:10.1149/2754-2726/ac7533 · Cited by 90
Smartphone-based immunosensor for CA125 detection
Hosu, O., Ravalli, A., Piccolo, G. M. L., Cristea, C., Săndulescu, R., & Marrazza, G. (2017) · Talanta · doi:10.1016/j.talanta.2017.01.073 · Cited by 90
Li, X., Yang, F., Wong, J. X. H., & Yu, H. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b01379 · Cited by 89
Recent Advancements in Enzyme-Based Lateral Flow Immunoassays
Calabria, D., Calabretta, M. M., Zangheri, M., Marchegiani, E., Trozzi, I., Guardigli, M., Michelini, E., Nardo, F. D., Anfossi, L., Baggiani, C., et al. (2021) · Sensors · doi:10.3390/s21103358 · Cited by 85
Self-citationHe, Z., Zang, S., Liu, Y., He, Y., & Lei, H. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.054 · Cited by 84
Fluorescence analyzer based on smartphone camera and wireless for detection of Ochratoxin A
Bueno, D., Muñoz, R., & Marty, J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.03.140 · Cited by 84
A comprehensive review of competitive lateral flow assays over the past decade
Pedreira-Rincón, J., Rivas, L., Comenge, J., Skouridou, V., Camprubí-Ferrer, D., Muñóz, J., O’Sullivan, C. K., Chamorro-García, A., & Parolo, C. (2025) · Lab on a Chip · doi:10.1039/d4lc01075b · Cited by 81
Chang, H., Lv, J., Zhang, H., Zhang, B., Wei, W., & Qiao, Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.002 · Cited by 80
Tang, Z., Liu, X., Su, B., Chen, Q., Cao, H., Yun, Y., Xu, Y., & Hammock, B. D. (2019) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2019.121678 · Cited by 82
Cortisol detection methods for stress monitoring in connected health
Iqbal, T., Elahi, A., Wijns, W. C., & Shahzad, A. (2023) · Health Sciences Review · doi:10.1016/j.hsr.2023.100079 · Cited by 95
Manickam, P., Pasha, S. K., Snipes, S. A., & Bhansali, S. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0781702jes · Cited by 78
Sun, A. C., Venkatesh, A. G., & Hall, D. A. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2586504 · Cited by 77
Paper strip-embedded graphene quantum dots: a screening device with a smartphone readout
Álvarez-Diduk, R., Orozco, J., & Merkoçi, A. (2017) · Scientific Reports · doi:10.1038/s41598-017-01134-3 · Cited by 76
Passive and wireless near field communication tag sensors for biochemical sensing with smartphone
Xu, G., Zhang, Q. Y., Lu, Y., Liu, L., Ji, D., Li, S., & Liu, Q. (2017) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2017.02.149 · Cited by 76
Hou, Y., Wang, K., Xiao, K., Qin, W., Lu, W., Tao, W., & Cui, D. (2017) · Nanoscale Research Letters · doi:10.1186/s11671-017-2078-9 · Cited by 74
Tian, G., Zhou, Z., Li, M., Li, X., Xu, T., & Zhang, X. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c02392 · Cited by 74
Zangheri, M., Nardo, F. D., Calabria, D., Marchegiani, E., Anfossi, L., Guardigli, M., Mirasoli, M., Baggiani, C., & Roda, A. (2021) · Analytica Chimica Acta · doi:10.1016/j.aca.2021.338515 · Cited by 73
Self-citationRuppert, C., Phogat, N., Laufer, S., Kohl, M., & Deigner, H. (2019) · Microchimica Acta · doi:10.1007/s00604-018-3195-6 · Cited by 71
Zhang, C., Wang, Y., Liu, Z., Bai, M., Wang, J., & Wang, Y. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132371 · Cited by 70
Panferov, V. G., Safenkova, I. V., Zherdev, A. V., & Dzantiev, B. B. (2020) · Talanta · doi:10.1016/j.talanta.2020.121961 · Cited by 66
Su, K., Zou, Q., Zhou, J., Zou, L., Li, H., Wang, T., Hu, N., & Wang, P. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.04.052 · Cited by 66
Kim, K. S., Ryeol, L. S., Kim, S., Lee, J. Y., Chung, C., Choe, W., & Yoo, P. J. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.09.135 · Cited by 66
Zangheri, M., Mirasoli, M., Guardigli, M., Nardo, F. D., Anfossi, L., Baggiani, C., Simoni, P., Benassai, M., & Roda, A. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.09.059 · Cited by 66
Self-citation
Metadata
- Authors
- Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A.
- Affiliations
- University of Bologna (IT)
- University of Turin (IT)
- Corresponding author
- Roda, Aldo
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 64
- Pages
- 63-68
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2080173526
- Cited by
- 373
- References
- 35
- Citations by year
- 2026: 10 · 2025: 26 · 2024: 27 · 2023: 23 · 2022: 30 · 2021: 37 · 2020: 38 · 2019: 42 · 2018: 44 · 2017: 32 · 2016: 41 · 2015: 23
- FWCI
- 16.62
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- PubMed (publishedVersion)
- Institutional Research Information System University of Turin (University of Turin) (submittedVersion, other-oa)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Advanced biosensing and bioanalysis techniques
- Keywords
- salivary cortisol, chemiluminescence, lateral flow immunoassay, smartphone biosensors, luminol, competitive immunoassay
- MeSH terms
- Equipment Design, Humans, Hydrocortisone, Immunoassay, Luminescent Measurements, Saliva, Biosensing Techniques, Point-of-Care Systems, Cell Phone, Limit of Detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review