Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 168

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

An ultrasensitive electrochemical aptasensor for the determination of tumor exosomes based on click chemistry

An, Yu, Jin, Tongyu, Zhu, Yuyuan, Zhang, Fan, He, Pingang · 2019 · Biosensors and Bioelectronics

Abstract

Exosomes, lipid bilayer membrane vesicles, can guide various pathological and physiological processes. However, reliable, convenient and sensitive methods for exosome determination for early cancer diagnosis are still technically challenging. Herein, an electrochemical aptasensor based on click chemistry and the DNA hybridization chain reaction (HCR) for signal amplification has been developed for the ultrasensitive detection of tumor exosomes. CD63 aptamer was first immobilized on a glassy carbon electrode for capturing exosomes, and 4-oxo-2-nonenal alkyne (alkynyl-4-ONE) molecules, functionalized lipid electrophiles, were conjugated to the exosomes via the reaction of amino and aldehyde groups. Azide-labeled DNA probe as an anchor was then connected to the exosomes by copper (I)-catalyzed click chemistry. Signal amplification was achieved by HCR, and the numerous linked horseradish peroxidase (HRP) molecules could catalyze the reaction of o-phenylenediamine (OPD) and H2O2. The concentration of exosomes could be quantified by monitoring the electrochemical reduction current of 2,3-diaminophenazine (DAP). Under the optimal conditions, this method allowed the sensitive detection of exosomes in the range of 1.12 × 102 to 1.12 × 108 particles/μL with a limit of detection (LOD) of 96 particles/μL. Furthermore, the present assay enabled sensitive and accurate quantification of exosomes in human serum, and it has high potential for exosome analysis in clinical samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2019.111503

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 168

Metadata

Authors
An, Y., Jin, T., Zhu, Y., Zhang, F., & He, P.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2019-10
Volume
142
Pages
111503
ISSN
0956-5663 (ISSN-L)
OpenAlex
W2961148088
Cited by
168
References
2
FWCI
6.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An ultrasensitive electrochemical aptasensor for the determination of tumor exosomes based on click chemistry. https://app.cochat.ai/papers/10.1016/j.bios.2019.111503
The paper
An, Y., Jin, T., Zhu, Y., Zhang, F., & He, P. (2019). An ultrasensitive electrochemical aptasensor for the determination of tumor exosomes based on click chemistry. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.111503

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.