The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
A novel optical fiber glucose biosensor based on carbon quantum dots-glucose oxidase/cellulose acetate complex sensitive film
Abstract
A novel optical fiber glucose biosensor based on fluorescent carbon quantum dots (CQDs)-glucose oxidase (GOD)/cellulose acetate (CA) complex sensitive film was fabricated, in which the dip-coating method was adopted to immobilize the CQDs-GOD/CA complex sensitive film onto the end face of the optical fiber. The surface morphology, microstructure and optical performances of the sensitive film were characterized by field emission scanning electron microscope (FESEM), atomic force microscope (AFM), Zeiss Axiovert 25 inverted microscope, Fourier transform infrared spectroscopy (FTIR), Ultraviolet-visible spectrophotometer and fluorescence spectrophotometer, respectively. The developed fiber-optic biosensor exhibits high sensitivity and repeatability for continuous online detection of low concentration glucose, allowing visualization of real-time glucose fluctuations over a period of time. The change ratios in fluorescence intensity of the biosensor are linear with glucose concentration in various ranges including micromole and nanomole levels, and the relationship between relative fluorescence intensity ratio and glucose concentration complies well with the modified Stern-Volmer equation in the range of 10-200 μmol/L with the detection limit of 6.43 μM, and in the range of 10-100 nmol/L with the detection limit of 25.79 nM, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Correlation Between Sweat Glucose and Blood Glucose in Subjects with Diabetes
Moyer, J., Wilson, D., Finkelshtein, I., Wong, B., & Potts, R. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0262 · Cited by 570
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185
Cited by
Optical biosensors: A decade in review
Singh, A. K., Mittal, S., Das, M., Saharia, A., & Tiwari, M. (2023) · Alexandria Engineering Journal · doi:10.1016/j.aej.2022.12.040 · Cited by 292
Recent advances in composites based on cellulose derivatives for biomedical applications
Oprea, M., & Voicu, S. I. (2020) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2020.116683 · Cited by 280
Recent Advances and Applications of Bacterial Cellulose in Biomedicine
Swingler, S., Gupta, A., Gibson, H., Kowalczuk, M., Heaselgrave, W., & Radecka, I. (2021) · Polymers · doi:10.3390/polym13030412 · Cited by 266
Metadata
- Authors
- Yu, S., Ding, L., Lin, H., Wu, W., & Huang, J.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 146
- Pages
- 111760
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W2977471137
- Cited by
- 158
- References
- 2
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel optical fiber glucose biosensor based on carbon quantum dots-glucose oxidase/cellulose acetate complex sensitive film. https://app.cochat.ai/papers/10.1016/j.bios.2019.111760
- The paper
- Yu, S., Ding, L., Lin, H., Wu, W., & Huang, J. (2019). A novel optical fiber glucose biosensor based on carbon quantum dots-glucose oxidase/cellulose acetate complex sensitive film. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2019.111760
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.