Measurement of Tear Glucose Levels with Amperometric Glucose Biosensor/Capillary Tube Configuration

Abstract

An amperometric needle-type electrochemical glucose sensor intended for tear glucose measurements is described and employed in conjunction with a 0.84 mm i.d. capillary tube to collect microliter volumes of tear fluid. The sensor is based on immobilizing glucose oxidase on a 0.25 mm o.d. platinum/iridium (Pt/Ir) wire and anodically detecting the liberated hydrogen peroxide from the enzymatic reaction. Inner layers of Nafion and an electropolymerized film of 1,3-diaminobenzene/resorcinol greatly enhance the selectivity for glucose over potential interferences in tear fluid, including ascorbic acid and uric acid. Further, the new sensor is optimized to achieve very low detection limits of 1.5 ± 0.4 μM of glucose (S/N = 3) that is required to monitor glucose levels in tear fluid with a glucose sensitivity of 0.032 ± 0.02 nA/μM (n = 6). Only 4-5 μL of tear fluid in the capillary tube is required when the needle sensor is inserted into the capillary. The glucose sensor was employed to measure tear glucose levels in anesthetized rabbits over an 8 h period while also measuring the blood glucose values. A strong correlation between tear and blood glucose levels was found, suggesting that measurement of tear glucose is a potential noninvasive substitute for blood glucose measurements, and the new sensor configuration could aid in conducting further research in this direction.

Overview

Integrity signals

Registry

Crossref · 10.1021/ac201700c

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 26 references

Research works printed but not linked: 1

  1. Choy C. K. M., 2000, Invest. Ophthalmol. Vis. Sci., 41, 3293

Cited by

See all 187

Metadata

Authors
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E.
Affiliations
University of Michigan (US)
Corresponding author
Meyerhoff, Mark E.
Venue
Analytical Chemistry
Published
2011-10-12
Volume
83
Issue
21
Pages
8341-8346
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2018860363
Cited by
185
References
26
Citations by year
2026: 5 · 2025: 8 · 2024: 10 · 2023: 13 · 2022: 13 · 2021: 21 · 2020: 15 · 2019: 14 · 2018: 13 · 2017: 20 · 2016: 14 · 2015: 11 · 2014: 17 · 2013: 6 · 2012: 5
FWCI
6.27
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
Keywords
tear glucose, amperometric glucose sensor, glucose oxidase immobilization, hydrogen peroxide detection, Nafion, ascorbic acid interference, uric acid interference, non-invasive glucose monitoring, rabbits
MeSH terms
Animals, Ascorbic Acid, Blood Glucose, Enzymes, Immobilized, Glucose, Glucose Oxidase, Hydrogen Peroxide, Iridium, Platinum, Rabbits, Resorcinols, Tears, Uric Acid, Biosensing Techniques, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Tear Glucose Levels with Amperometric Glucose Biosensor/Capillary Tube Configuration. https://app.cochat.ai/papers/10.1021/ac201700c
The paper
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011). Measurement of Tear Glucose Levels with Amperometric Glucose Biosensor/Capillary Tube Configuration. Analytical Chemistry. https://doi.org/10.1021/ac201700c

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.