Measurement of Tear Glucose Levels with Amperometric Glucose Biosensor/Capillary Tube Configuration
Abstract
An amperometric needle-type electrochemical glucose sensor intended for tear glucose measurements is described and employed in conjunction with a 0.84 mm i.d. capillary tube to collect microliter volumes of tear fluid. The sensor is based on immobilizing glucose oxidase on a 0.25 mm o.d. platinum/iridium (Pt/Ir) wire and anodically detecting the liberated hydrogen peroxide from the enzymatic reaction. Inner layers of Nafion and an electropolymerized film of 1,3-diaminobenzene/resorcinol greatly enhance the selectivity for glucose over potential interferences in tear fluid, including ascorbic acid and uric acid. Further, the new sensor is optimized to achieve very low detection limits of 1.5 ± 0.4 μM of glucose (S/N = 3) that is required to monitor glucose levels in tear fluid with a glucose sensitivity of 0.032 ± 0.02 nA/μM (n = 6). Only 4-5 μL of tear fluid in the capillary tube is required when the needle sensor is inserted into the capillary. The glucose sensor was employed to measure tear glucose levels in anesthetized rabbits over an 8 h period while also measuring the blood glucose values. A strong correlation between tear and blood glucose levels was found, suggesting that measurement of tear glucose is a potential noninvasive substitute for blood glucose measurements, and the new sensor configuration could aid in conducting further research in this direction.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The same source of variability, if present in human tears, may be at least partly responsible for the inability to establish a clinically sound blood-to-tear correlation in human subjects (247).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [247]
In the citing paper
“Variability is reported in the ratio between glucose concentrations in blood and tear fluid for individual rabbits (247).”
From Guidelines and Recommendations for Laboratory Analysis in the Diagnosis and Management of Diabetes Mellitus (2023) · cites this paper as [247]
In the citing paper
“Despite the demonstrated correlations, sampling tears for in vitro diagnoses is associated with several errors that are due to the following: first, small sample volumes102; second, ease of evaporation during sample collection; third, variations in tear production among individuals and throughout the day103; and lastly, challenging collection methods that can affect the sampled analyte concentra”
From Wearable biosensors for healthcare monitoring (2019) · cites this paper as [104]
Citations
Cites
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309
Saha, J. K., Xia, J., Grondin, J. M., Engle, S. K., & Jakubowski, J. A. (2005) · Experimental Biology and Medicine · doi:10.1177/153537020523001012 · Cited by 274
Current development in non-invasive glucose monitoring
Ferrante do Amaral, C. E., & Wolf, B. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.06.003 · Cited by 269
Glucose monitoring by reverse iontophoresis
Potts, R. O., A. Tamada, J., & J. Tierney, M. (2002) · Diabetes/Metabolism Research and Reviews · doi:10.1002/dmrr.210 · Cited by 243
Tear glucose levels in normal people and in diabetic patients.
Sen, D. K., & Sarin, G. S. (1980) · British Journal of Ophthalmology · doi:10.1136/bjo.64.9.693 · Cited by 203
Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
Baca, J. T., Finegold, D. N., & Asher, S. A. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70094-0 · Cited by 187
Electropolymerized films to prevent interferences and electrode fouling in biosensors
Geise, R. J., Adams, J. M., Barone, N. J., & Yacynych, A. M. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)87039-e · Cited by 169
Major, T. C., Brant, D. O., Reynolds, M. M., Bartlett, R. H., Meyerhoff, M. E., Handa, H., & Annich, G. M. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.12.028 · Cited by 146
Self-citationMass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers
Baca, J. T., Taormina, C. R., Feingold, E., Finegold, D. N., Grabowski, J. J., & Asher, S. A. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.078543 · Cited by 110
A glucose-sensing contact lens: from bench top to patient
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2004.12.007 · Cited by 105
Research works printed but not linked: 1
- Choy C. K. M., 2000, Invest. Ophthalmol. Vis. Sci., 41, 3293
Cited by
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Non-invasive wearable electrochemical sensors: a review
Bandodkar, A. J., & Wang, J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.04.005 · Cited by 1,247
Electrochemical Methods for the Analysis of Clinically Relevant Biomolecules
Labib, M., Sargent, E. H., & Kelley, S. O. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00220 · Cited by 976
Electrochemical glucose sensors in diabetes management: an updated review (2010–2020)
Teymourian, H., Barfidokht, A., & Wang, J. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00304b · Cited by 881
Metadata
- Authors
- Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E.
- Affiliations
- University of Michigan (US)
- Corresponding author
- Meyerhoff, Mark E.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-12
- Volume
- 83
- Issue
- 21
- Pages
- 8341-8346
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2018860363
- Semantic Scholar
- 2bac2226ca694c079ac35a58255ced63f9971be4
- Cited by
- 185
- References
- 26
- Citations by year
- 2026: 5 · 2025: 8 · 2024: 10 · 2023: 13 · 2022: 13 · 2021: 21 · 2020: 15 · 2019: 14 · 2018: 13 · 2017: 20 · 2016: 14 · 2015: 11 · 2014: 17 · 2013: 6 · 2012: 5
- FWCI
- 6.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- tear glucose, amperometric glucose sensor, glucose oxidase immobilization, hydrogen peroxide detection, Nafion, ascorbic acid interference, uric acid interference, non-invasive glucose monitoring, rabbits
- MeSH terms
- Animals, Ascorbic Acid, Blood Glucose, Enzymes, Immobilized, Glucose, Glucose Oxidase, Hydrogen Peroxide, Iridium, Platinum, Rabbits, Resorcinols, Tears, Uric Acid, Biosensing Techniques, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of Tear Glucose Levels with Amperometric Glucose Biosensor/Capillary Tube Configuration. https://app.cochat.ai/papers/10.1021/ac201700c
- The paper
- Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011). Measurement of Tear Glucose Levels with Amperometric Glucose Biosensor/Capillary Tube Configuration. Analytical Chemistry. https://doi.org/10.1021/ac201700c
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.