The DOI matches its Crossref record; 80 of the 80 references it cites were found in a registry or an index.
Diagnostic methods and potential portable biosensors for coronavirus disease 2019
Open accessAbstract
Timely detection and diagnosis are urgently needed to guide epidemiological measures, infection control, antiviral treatment, and vaccine research. In this review, biomarkers/indicators for diagnosis of coronavirus disease 2019 (COVID-19) or detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in the environment are summarized and discussed. It is concluded that the detection methods targeting antibodies are not suitable for screening of early and asymptomatic cases since most patients had an antibody response at about 10 days after onset of symptoms. However, antibody detection methods can be combined with quantitative real-time reverse transcriptase-polymerase chain reaction (RT-qPCR) to significantly improve the sensitivity and specificity of diagnosis, and boost vaccine research. Fast, sensitive and accurate detection methods targeting antigens need to be developed urgently. Various specimens for diagnosis or detection are compared and analyzed. Among them, deep throat saliva and induced sputum are desired for RT-qPCR test or other early detection technologies. Chest computerized tomography (CT) scan, RT-qPCR, lateral flow immunochromatographic strip (LFICS) for diagnosis of COVID-19 are summarized and compared. Specially, potential electrochemical (EC) biosensor, surface enhanced Raman scattering (SERS)-based biosensor, field-effect transistor (FET)-based biosensor, surface plasmon resonance (SPR)-based biosensor and artificial intelligence (AI) assisted diagnosis of COVID-19 are emphasized. Finally, some commercialized portable detection device, current challenges and future directions are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A pneumonia outbreak associated with a new coronavirus of probable bat origin
Zhou, P., Yang, X.-L., Wang, X.-G., Hu, B., Zhang, L., Zhang, W., Si, H.-R., Zhu, Y., Li, B., Huang, C.-L., et al. (2020) · Nature · doi:10.1038/s41586-020-2012-7 · Cited by 21,969
Lu, R., Zhao, X., Li, J., Niu, P., Yang, B., Wu, H., Wang, W., Song, H., Huang, B., Zhu, N., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30251-8 · Cited by 11,907
Self-citationAerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1
van Doremalen, N., Bushmaker, T., Morris, D. H., Holbrook, M. G., Gamble, A., Williamson, B. N., Tamin, A., Harcourt, J. L., Thornburg, N. J., Gerber, S. I., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2004973 · Cited by 9,951
Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR
Corman, V. M., Landt, O., Kaiser, M., Molenkamp, R., Meijer, A., Chu, D. K., Bleicker, T., Brünink, S., Schneider, J., Schmidt, M. L., et al. (2020) · Eurosurveillance · doi:10.2807/1560-7917.es.2020.25.3.2000045 · Cited by 7,344
Ai, T., Yang, Z., Hou, H., Zhan, C., Chen, C., Lv, W., Tao, Q., Sun, Z., & Xia, L. (2020) · Radiology · doi:10.1148/radiol.2020200642 · Cited by 5,685
Detection of SARS-CoV-2 in Different Types of Clinical Specimens
Wang, W., Xu, Y., Gao, R., Lu, R., Han, K., Wu, G., & Tan, W. (2020) · JAMA · doi:10.1001/jama.2020.3786 · Cited by 5,028
SARS-CoV-2 Viral Load in Upper Respiratory Specimens of Infected Patients
Zou, L., Ruan, F., Huang, M., Liang, L., Huang, H., Hong, Z., Yu, J., Kang, M., Song, Y., Xia, J., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2001737 · Cited by 4,810
Guo (2020) · doi:10.1186/s40779-020-00240-0 · Cited by 4,735
Sensitivity of Chest CT for COVID-19: Comparison to RT-PCR
Fang, Y., Zhang, H., Xie, J., Lin, M., Ying, L., Pang, P., & Ji, W. (2020) · Radiology · doi:10.1148/radiol.2020200432 · Cited by 3,354
To, K. K.-W., Tsang, O. T.-Y., Leung, W.-S., Tam, A. R., Wu, T.-C., Lung, D. C., Yip, C. C.-Y., Cai, J.-P., Chan, J. M.-C., Chik, T. S.-H., et al. (2020) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(20)30196-1 · Cited by 3,066
Cited by
Li, Z., Yi, Y., Luo, X., Xiong, N., Liu, Y., Li, S., Sun, R., Wang, Y., Hu, B., Chen, W., et al. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25727 · Cited by 1,771
Coronavirus Disease 2019 (COVID-19): Role of Chest CT in Diagnosis and Management
Li, Y., & Xia, L. (2020) · American Journal of Roentgenology · doi:10.2214/ajr.20.22954 · Cited by 1,294
The genetic sequence, origin, and diagnosis of SARS-CoV-2
Wang, H., Li, X., Li, T., Zhang, S., Wang, L., Wu, X., & Liu, J. (2020) · European Journal of Clinical Microbiology & Infectious Diseases · doi:10.1007/s10096-020-03899-4 · Cited by 491
Zhu, X., Wang, X., Han, L., Chen, T., Wang, L., Li, H., Li, S., He, L., Fu, X., Chen, S., et al. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112437 · Cited by 454
Fabiani, L., Saroglia, M., Galatà, G., De Santis, R., Fillo, S., Luca, V., Faggioni, G., D'Amore, N., Regalbuto, E., Salvatori, P., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112686 · Cited by 434
Safiabadi Tali, S. H., LeBlanc, J. J., Sadiq, Z., Oyewunmi, O. D., Camargo, C., Nikpour, B., Armanfard, N., Sagan, S. M., & Jahanshahi-Anbuhi, S. (2021) · Clinical Microbiology Reviews · doi:10.1128/cmr.00228-20 · Cited by 405
Detection and beyond: challenges and advances in aptamer-based biosensors
Yoo, H., Jo, H., & Oh, S. S. (2020) · Materials Advances · doi:10.1039/d0ma00639d · Cited by 334
Funari, R., Chu, K.-Y., & Shen, A. Q. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112578 · Cited by 279
Liu, H., Dai, E., Xiao, R., Zhou, Z., Zhang, M., Bai, Z., Shao, Y., Qi, K., Tu, J., Wang, C., et al. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.129196 · Cited by 267
Emerging Telemedicine Tools for Remote COVID-19 Diagnosis, Monitoring, and Management
Lukas, H., Xu, C., Yu, Y., & Gao, W. (2020) · ACS Nano · doi:10.1021/acsnano.0c08494 · Cited by 265
Metadata
- Authors
- Cui, F., & Zhou, H. S.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 165
- Pages
- 112349
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3029841422
- Cited by
- 373
- References
- 80
- FWCI
- 9.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.