Ultrasensitive detection of pathogenic viruses with electrochemical biosensor: State of the art
Open accessThe DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Abstract
Abstract Last few decades, viruses are a real menace to human safety. Therefore, the rapid identification of viruses should be one of the best ways to prevent an outbreak and important implications for medical healthcare. The recent outbreak of coronavirus disease (COVID-19) is an infectious disease caused by a newly discovered coronavirus which belongs to the single-stranded, positive-strand RNA viruses. The pandemic dimension spread of COVID-19 poses a severe threat to the health and lives of seven billion people worldwide. There is a growing urgency worldwide to establish a point-of-care device for the rapid detection of COVID-19 to prevent subsequent secondary spread. Therefore, the need for sensitive, selective, and rapid diagnostic devices plays a vital role in selecting appropriate treatments and to prevent the epidemics. During the last decade, electrochemical biosensors have emerged as reliable analytical devices and represent a new promising tool for the detection of different pathogenic viruses. This review summarizes the state of the art of different virus detection with currently available electrochemical detection methods. Moreover, this review discusses different fabrication techniques, detection principles, and applications of various virus biosensors. Future research also looks at the use of electrochemical biosensors regarding a potential detection kit for the rapid identification of the COVID-19.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A pneumonia outbreak associated with a new coronavirus of probable bat origin
Zhou, P., Yang, X.-L., Wang, X.-G., Hu, B., Zhang, L., Zhang, W., Si, H.-R., Zhu, Y., Li, B., Huang, C.-L., et al. (2020) · Nature · doi:10.1038/s41586-020-2012-7 · Cited by 21,969
Lu, R., Zhao, X., Li, J., Niu, P., Yang, B., Wu, H., Wang, W., Song, H., Huang, B., Zhu, N., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30251-8 · Cited by 11,907
Presumed Asymptomatic Carrier Transmission of COVID-19
Bai, Y., Yao, L., Wei, T., Tian, F., Jin, D.-Y., Chen, L., & Wang, M. (2020) · JAMA · doi:10.1001/jama.2020.2565 · Cited by 4,498
Antibody Responses to SARS-CoV-2 in Patients With Novel Coronavirus Disease 2019
Zhao, J., Yuan, Q., Wang, H., Liu, W., Liao, X., Su, Y., Wang, X., Yuan, J., Li, T., Li, J., et al. (2020) · Clinical Infectious Diseases · doi:10.1093/cid/ciaa344 · Cited by 2,607
Seo, G., Lee, G., Kim, M. J., Baek, S.-H., Choi, M., Ku, K. B., Lee, C.-S., Jun, S., Park, D., Kim, H. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02823 · Cited by 1,837
Li, Z., Yi, Y., Luo, X., Xiong, N., Liu, Y., Li, S., Sun, R., Wang, Y., Hu, B., Chen, W., et al. (2020) · Journal of Medical Virology · doi:10.1002/jmv.25727 · Cited by 1,771
Molecular Diagnosis of a Novel Coronavirus (2019-nCoV) Causing an Outbreak of Pneumonia
Chu, D. K. W., Pan, Y., Cheng, S. M. S., Hui, K. P. Y., Krishnan, P., Liu, Y., Ng, D. Y. M., Wan, C. K. C., Yang, P., Wang, Q., et al. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa029 · Cited by 1,278
Unravelling the Role of O-glycans in Influenza A Virus Infection
Mayr, J., Lau, K., Lai, J. C. C., Gagarinov, I. A., Shi, Y., McAtamney, S., Chan, R. W. Y., Nicholls, J., von Itzstein, M., & Haselhorst, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-34175-3 · Cited by 1,069
Qiu, G., Gai, Z., Tao, Y., Schmitt, J., Kullak-Ublick, G. A., & Wang, J. (2020) · ACS Nano · doi:10.1021/acsnano.0c02439 · Cited by 1,059
Immunosensors—principles and applications to clinical chemistry
Luppa, P. B., Sokoll, L. J., & Chan, D. W. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00629-5 · Cited by 741
Hajian, R., Balderston, S., Tran, T., deBoer, T., Etienne, J., Sandhu, M., Wauford, N. A., Chung, J.-Y., Nokes, J., Athaiya, M., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0371-x · Cited by 646
APPLICATIONS OF DNA MICROARRAYS IN BIOLOGY
Stoughton, R. B. (2005) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.74.082803.133212 · Cited by 390
Layqah, L. A., & Eissa, S. (2019) · Microchimica Acta · doi:10.1007/s00604-019-3345-5 · Cited by 380
Kwon, P. S., Ren, S., Kwon, S.-J., Kizer, M. E., Kuo, L., Xie, M., Zhu, D., Zhou, F., Zhang, F., Kim, D., et al. (2020) · Nature Chemistry · doi:10.1038/s41557-019-0369-8 · Cited by 315
Gold Nanoclusters and Graphene Nanocomposites for Drug Delivery and Imaging of Cancer Cells
Wang, C., Li, J., Amatore, C., Chen, Y., Jiang, H., & Wang, X. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201105573 · Cited by 294
Biosensors for plant pathogen detection
Khater, M., de la Escosura-Muñiz, A., & Merkoçi, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.09.091 · Cited by 281
N6-methyladenosine modification enables viral RNA to escape recognition by RNA sensor RIG-I
Lu, M., Zhang, Z., Xue, M., Zhao, B. S., Harder, O., Li, A., Liang, X., Gao, T. Z., Xu, Y., Zhou, J., et al. (2020) · Nature Microbiology · doi:10.1038/s41564-019-0653-9 · Cited by 273
Xiang, J., Yan, M., Li, H., Liu, T., Lin, C., Huang, S., & Shen, C. (2020) · medRxiv · doi:10.1101/2020.02.27.20028787 · Cited by 239
Electrochemical paper-based peptide nucleic acid biosensor for detecting human papillomavirus
Teengam, P., Siangproh, W., Tuantranont, A., Henry, C. S., Vilaivan, T., & Chailapakul, O. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.11.071 · Cited by 236
From Point-of-Care Testing to eHealth Diagnostic Devices (eDiagnostics)
Christodouleas, D. C., Kaur, B., & Chorti, P. (2018) · ACS Central Science · doi:10.1021/acscentsci.8b00625 · Cited by 210
Antibody Responses to SARS-CoV-2 in Patients of Novel Coronavirus Disease 2019
Zhao, J., Yuan, Q., Wang, H., Liu, W., Liao, X., Su, Y., Wang, X., Yuan, J., Li, T., Li, J., et al. (2020) · SSRN Electronic Journal · doi:10.2139/ssrn.3546052 · Cited by 208
Glynou, K., Ioannou, P. C., Christopoulos, T. K., & Syriopoulou, V. (2003) · Analytical Chemistry · doi:10.1021/ac034256+ · Cited by 202
Dong, S., Zhao, R., Zhu, J., Lu, X., Li, Y., Qiu, S., Jia, L., Jiao, X., Song, S., Fan, C., et al. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b01438 · Cited by 198
Tsang, M.-K., Ye, W., Wang, G., Li, J., Yang, M., & Hao, J. (2016) · ACS Nano · doi:10.1021/acsnano.5b05622 · Cited by 195
A sensitive electrochemical immunosensor for label-free detection of Zika-virus protein
Kaushik, A. K., Yndart, A., Kumar, S., Jayant, R. D., Vashist, A., Brown, A. N., Li, C.-Z., & Nair, M. G. (2018) · Scientific Reports · doi:10.1038/s41598-018-28035-3 · Cited by 194
Clinical characteristics of recovered COVID-19 patients with re-detectable positive RNA test
An, J., Liao, X., Xiao, T., Qian, S., Yuan, J., Ye, H., Qi, F., Shen, C., Wang, L., Liu, Y., et al. (2020) · Annals of Translational Medicine · doi:10.21037/atm-20-5602 · Cited by 187
Lee, J., Morita, M., Takemura, K., & Park, E. Y. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.11.052 · Cited by 166
Label-free electrochemical DNA biosensor for zika virus identification
Faria, H. A. M., & Zucolotto, V. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.02.018 · Cited by 165
Field-Effect Transistor Biosensor for Rapid Detection of Ebola Antigen
Chen, Y., Ren, R., Pu, H., Guo, X., Chang, J., Zhou, G., Mao, S., Kron, M., & Chen, J. (2017) · Scientific Reports · doi:10.1038/s41598-017-11387-7 · Cited by 162
Electrochemical lateral flow immunosensor for detection and quantification of dengue NS1 protein
Sinawang, P. D., Rai, V., Ionescu, R. E., & Marks, R. S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.048 · Cited by 158
Electrochemical Immunosensors for Antibiotic Detection
Pollap, A., & Kochana, J. (2019) · Biosensors · doi:10.3390/bios9020061 · Cited by 143
Zhang, D., Peng, Y., Qi, H., Gao, Q., & Zhang, C. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.09.032 · Cited by 134
Tam, P. D., Hieu, N. V., Chiến, N. Đ., Le, A., & Anh, T. M. (2009) · Journal of Immunological Methods · doi:10.1016/j.jim.2009.08.002 · Cited by 130
A high fidelity CRISPR/Cas12a based lateral flow biosensor for the detection of HPV16 and HPV18
Mukama, O., Yuan, T., He, Z., Li, Z., Habimana, J. D. D., Hussain, M., Li, W., Yi, Z., Liang, Q., & Zeng, L. (2020) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2020.128119 · Cited by 127
A novel electrochemical DNA biosensor for Ebola virus detection
Ilkhani, H., & Farhad, S. (2018) · Analytical Biochemistry · doi:10.1016/j.ab.2018.06.010 · Cited by 126
Baek, S. H., Kim, M. W., Park, C. Y., Choi, C., Kailasa, S. K., Park, J. P., & Park, T. J. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.08.064 · Cited by 113
Wang, S., Li, L., Jin, H., Yang, T., Bao, W., Huang, S., & Wang, J. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.08.021 · Cited by 110
Luo, X., Lee, T. M. H., & Hsing, I. (2008) · Analytical Chemistry · doi:10.1021/ac8010236 · Cited by 109
Cao, X., Cao, X., Guo, H., Li, T., Wang, Z. L., Wang, N., & Wang, Z. L. (2016) · ACS Nano · doi:10.1021/acsnano.6b04121 · Cited by 95
Micropatterned reduced graphene oxide based field-effect transistor for real-time virus detection
Liu, F., Kim, Y. H., Cheon, D. S., & Seo, T. S. (2013) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2013.05.097 · Cited by 93
Steinmetz, M., Lima, D., Viana, A. G., Fujiwara, S. T., Pessôa, C. A., Etto, R. M., & Wohnrath, K. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111351 · Cited by 91
Label-Free Electrochemical Detection of DNA Hybridization: A Method for COVID-19 Diagnosis
Tripathy, S., & Singh, S. G. (2020) · Transactions of Indian National Academy of Engineering · doi:10.1007/s41403-020-00103-z · Cited by 86
Nasrin, F., Chowdhury, A. D., Takemura, K., Kozaki, I., Honda, H., Adegoke, O., & Park, E. Y. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.02.039 · Cited by 84
Mazloum‐Ardakani, M., Hosseinzadeh, L., & Khoshroo, A. (2015) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2015.09.006 · Cited by 83
Mishra, N. N., Retterer, S. T., Zieziulewicz, T. J., Isaacson, M., Szarowski, D. H., Mousseau, D. E., Lawrence, D. A., & Turner, J. N. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2005.01.011 · Cited by 78
Monitoring viral-induced cell death using electric cell–substrate impedance sensing
Campbell, C. E., Laane, M. M., Haugarvoll, E., & Giæver, I. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.06.015 · Cited by 78
A novel biosensor based on serum antibody immobilization for rapid detection of viral antigens
Huy, T. Q., Hạnh, N. T. H., Thủy, N. T., Chung, P. V., Nga, P. T., & Anh, T. M. (2011) · Talanta · doi:10.1016/j.talanta.2011.09.012 · Cited by 68
Nanoparticle-based biosensor for the detection of emerging pandemic influenza strains
Kamikawa, T. L., Mikolajczyk, M. G., Kennedy, M., Zhang, P. C., Wang, W., Scott, D. E., & Alocilja, E. C. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.047 · Cited by 68
Red Laser-Induced Fluorescence Energy Transfer in an Immunosystem
Oswald, B., Lehmann, F., Simon, L., Terpetschnig, E., & Wolfbeis, O. S. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4553 · Cited by 64
Zheng, L., Jia, L., Li, B., Situ, B., Liu, Q., Wang, Q., & Gan, N. (2012) · Molecules · doi:10.3390/molecules17055988 · Cited by 62
A dual marker label free electrochemical assay for Flavivirus dengue diagnosis
Santos, A., Bueno, P. R., & Davis, J. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.014 · Cited by 60
Sun, W., Zhong, J., Qin, P., & Jiao, K. (2008) · Analytical Biochemistry · doi:10.1016/j.ab.2008.03.027 · Cited by 60
Simple and effective label free electrochemical immunosensor for Fig mosaic virus detection
Haji-Hashemi, H., Safarnejad, M. R., Norouzi, P., Ebrahimi, M., Shahmirzaie, M., & Ganjali, M. R. (2018) · Analytical Biochemistry · doi:10.1016/j.ab.2018.11.017 · Cited by 48
Adam, V., Húska, D., Hubálek, J., & Kizek, R. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0464-z · Cited by 46
Impedance spectroscopy and affinity measurement of specific antibody–antigen interaction
Tlili, A., Abdelghani, A., Ameur, S., & Jaffrezic-Renault, N. J. (2005) · Materials Science and Engineering C · doi:10.1016/j.msec.2005.10.007 · Cited by 43
Kumar, N., Bhatia, S., Pateriya, A. K., Sood, R., Nagarajan, S., Murugkar, H. V., Kumar, S., Singh, P., & Singh, V. P. (2019) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.09.060 · Cited by 41
George, A., Amrutha, M. S., Srivastava, P., Sai, V. V. R., Sunil, S., & Srinivasan, R. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.1081914jes · Cited by 39
Chinnadayyala, S. R., Park, J., Abbasi, M. A., & Cho, S. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111642 · Cited by 38
Anti-Fab Aptamers for Shielding Virus from Neutralizing Antibodies
Muharemagic, D., Labib, M., Ghobadloo, S. M., Zamay, A. S., Bell, J. C., & Berezovski, M. V. (2012) · Journal of the American Chemical Society · doi:10.1021/ja306856y · Cited by 38
Xue, D., Elliott, C. M., Gong, P., Grainger, D. W., Bignozzi, C. A., & Caramori, S. (2007) · Journal of the American Chemical Society · doi:10.1021/ja067339r · Cited by 31
Krejčová, L., Húska, D., Hynek, D., Kopel, P., Adam, V., Hubálek, J., Trnková, L., & Kizek, R. (2013) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)14051-x · Cited by 29
Subak, H., & Ozkan‐Ariksoysal, D. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.02.089 · Cited by 22
Supported protein G on gold electrode: Characterization and immunosensor application
Hafaiedh, I., Chammem, H., Abdelghani, A., Ait‐Yahiatène, E., Feldman, L. J., Meilhac, O., & Mora, L. (2013) · Talanta · doi:10.1016/j.talanta.2013.04.059 · Cited by 21
Zhang, X., Zhou, D., Sheng, S., Yang, J., Chen, X., Xie, G., & Xiang, H. (2016) · Microchimica Acta · doi:10.1007/s00604-016-1848-x · Cited by 20
Triangular silver nanoplates: Properties and ultrasensitive detection of miRNA
McArdle, H., Spain, E., Keyes, T. E., Stallings, R. L., Fournet, M. B., & Forster, R. J. (2017) · Electrochemistry Communications · doi:10.1016/j.elecom.2017.04.010 · Cited by 16
Radhakrishnan, R., Pali, M. L., Lee, H. J., Lee, T. R., & Suni, I. I. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0301605jes · Cited by 15
Cited by
Electrochemical impedance spectroscopy
Wang, S., Zhang, J., Gharbi, O., Vivier, V., Gao, M., & Orazem, M. E. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00039-w · Cited by 1,140
Biosensors for the Detection of Bacterial and Viral Clinical Pathogens
Castillo-Henríquez, L., Brenes-Acuña, M., Castro-Rojas, A., Cordero-Salmerón, R., Lopretti-Correa, M., & Vega-Baudrit, J. R. (2020) · Sensors · doi:10.3390/s20236926 · Cited by 196
Nanozyme‐Enhanced Electrochemical Biosensors: Mechanisms and Applications
Yang, Z., Guo, J., Wang, L., Zhang, J., Ding, L., Liu, H., & Yu, X. (2024) · Small · doi:10.1002/smll.202307815 · Cited by 183
Metadata
- Authors
- Khan, M. Z. H., Hasan, M. R., Hossain, S. I., Ahommed, M. S., & Daizy, M.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 166
- Pages
- 112431
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3043645202
- Cited by
- 224
- References
- 67
- FWCI
- 12.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.