The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Stretchable respiration sensors: Advanced designs and multifunctional platforms for wearable physiological monitoring
Open accessAbstract
Respiration signals are a vital sign of life. Monitoring human breath provides critical information for health assessment, diagnosis, and treatment for respiratory diseases such as asthma, chronic bronchitis, and emphysema. Stretchable and wearable respiration sensors have recently attracted considerable interest toward monitoring physiological signals in the era of real time and portable healthcare systems. This review provides a snapshot on the recent development of stretchable sensors and wearable technologies for respiration monitoring. The article offers the fundamental guideline on the sensing mechanisms and design concepts of stretchable sensors for detecting vital breath signals such as temperature, humidity, airflow, stress and strain. A highlight on the recent progress in the integration of variable sensing components outlines feasible pathways towards multifunctional and multimodal sensor platforms. Structural designs of nanomaterials and platforms for stretchable respiration sensors are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Detecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207
Progress in triboelectric nanogenerators as a new energy technology and self-powered sensors
Wang, Z. L., Chen, J., & Lin, L. (2015) · Energy & Environmental Science · doi:10.1039/c5ee01532d · Cited by 2,174
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
A stretchable and biodegradable strain and pressure sensor for orthopaedic application
Boutry, C. M., Kaizawa, Y., Schroeder, B. C., Chortos, A., Legrand, A., Wang, Z., Chang, J., Fox, P., & Bao, Z. (2018) · Nature Electronics · doi:10.1038/s41928-018-0071-7 · Cited by 667
Physiologic Effects of High-Flow Nasal Cannula in Acute Hypoxemic Respiratory Failure
Mauri, T., Turrini, C., Eronia, N., Grasselli, G., Volta, C. A., Bellani, G., & Pesenti, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201605-0916oc · Cited by 641
Liu, Q., Chen, J., Li, Y., & Shi, G. (2016) · ACS Nano · doi:10.1021/acsnano.6b03813 · Cited by 609
Cited by
Electronic Textiles for Wearable Point-of-Care Systems
Chen, G., Xiao, X., Zhao, X., Tat, T., Bick, M., & Chen, J. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00502 · Cited by 688
Ning, C., Cheng, R., Jiang, Y., Sheng, F., Yi, J., Shen, S., Zhang, Y., Peng, X., Dong, K., & Wang, Z. L. (2022) · ACS Nano · doi:10.1021/acsnano.1c09792 · Cited by 279
Khoshmanesh, F., Thurgood, P., Pirogova, E., Nahavandi, S., & Baratchi, S. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112946 · Cited by 204
Phatak, A. A., Wieland, F.-G., Vempala, K., Volkmar, F., & Memmert, D. (2021) · Sports Medicine - Open · doi:10.1186/s40798-021-00372-0 · Cited by 74
Comparison of Wearable and Clinical Devices for Acquisition of Peripheral Nervous System Signals
Bizzego, A., Gabrieli, G., Furlanello, C., & Esposito, G. (2020) · Sensors · doi:10.3390/s20236778 · Cited by 25
Metadata
- Authors
- Dinh, T., Nguyen, T., Phan, H.-P., Nguyen, N.-T., Dao, D. V., & Bell, J.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 166
- Pages
- 112460
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3043336687
- Cited by
- 205
- References
- 25
- FWCI
- 8.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stretchable respiration sensors: Advanced designs and multifunctional platforms for wearable physiological monitoring. https://app.cochat.ai/papers/10.1016/j.bios.2020.112460
- The paper
- Dinh, T., Nguyen, T., Phan, H.-P., Nguyen, N.-T., Dao, D. V., & Bell, J. (2020). Stretchable respiration sensors: Advanced designs and multifunctional platforms for wearable physiological monitoring. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2020.112460
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.