AIEgens enabled ultrasensitive point-of-care test for multiple targets of food safety: Aflatoxin B1 and cyclopiazonic acid as an example
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Food safety is currently a significant issue for human life and health. Various fluorescent nanomaterials have been applied in the point-of-care test (POCT) for food safety as labeling materials. However, previous fluorescent nanomaterials can cause aggregation-caused quenching (ACQ), thus reducing the detection sensitivity. Conversely, aggregation-induced emission luminogens (AIEgens) are promising candidates for POCT in the food safety field because they can enhance detection sensitivity and throughput. Mycotoxins, such as aflatoxin B1 (AFB1) and cyclopiazonic acid (CPA), are a primary threat to human life and health and a significant food safety issue, and their on-site detection from farm to table is needed. Herein, an ultrasensitive point-of-care test was developed based on TPE-Br, a blue-emissive tetraphenylethylene derivative AIEgen. Under optimal conditions, this AIEgen-based lateral-flow biosensor (ALFB) allowed for a rapid response of 8 min toward AFB1 and CPA detection, with considerable sensitivities of 0.003 and 0.01 ng/mL in peanut matrices, respectively. In peanut matrices, the recoveries were 90.3%-110.0% for both mycotoxins, with relative standard deviations (RSDs) below 6%. The ALFB was further validated via UPLC-MS/MS using spiked peanut samples. AIEgens open an avenue for on-site, ultrasensitive, high-throughput detection methods and can be extensively used in point-of-care tests in food safety.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aggregation-Induced Emission: Together We Shine, United We Soar!
Mei, J., Leung, N. L. C., Kwok, R. T. K., Lam, J. W. Y., & Tang, B. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00263 · Cited by 8,270
Self-citationHong, Y., Lam, J. W. Y., & Tang, B. Z. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15113d · Cited by 6,363
Self-citationAggregation-induced emission: phenomenon, mechanism and applications
Hong, Y., Lam, J. W. Y., & Tang, B. Z. (2009) · Chemical Communications · doi:10.1039/b904665h · Cited by 4,115
Self-citationLimit of detection. A closer look at the IUPAC definition
Long, G. L., & Winefordner, J. D. (1983) · Analytical Chemistry · doi:10.1021/ac00258a001 · Cited by 2,162
Fungal secondary metabolism — from biochemistry to genomics
Keller, N. P., Turner, G., & Bennett, J. W. (2005) · Nature Reviews Microbiology · doi:10.1038/nrmicro1286 · Cited by 1,731
Yuan, W. Z., Lu, P., Chen, S., Lam, J. W. Y., Wang, Z., Liu, Y., Kwok, H. S., Ma, Y., & Tang, B. Z. (2010) · Advanced Materials · doi:10.1002/adma.200904056 · Cited by 971
Self-citationAflatoxins: A Global Concern for Food Safety, Human Health and Their Management
Kumar, P., Mahato, D. K., Kamle, M., Mohanta, T. K., & Kang, S. G. (2017) · Frontiers in Microbiology · doi:10.3389/fmicb.2016.02170 · Cited by 843
Lateral flow assays: Principles, designs and labels
Bahadır, E. B., & Sezgintürk, M. K. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.06.006 · Cited by 682
Huang, X., Aguilar, Z. P., Xu, H., Lai, W., & Xiong, Y. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.032 · Cited by 499
Photonic crystals: emerging biosensors and their promise for point-of-care applications
Inan, H., Poyraz, M., Inci, F., Lifson, M. A., Baday, M., Cunningham, B. T., & Demirci, U. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00206d · Cited by 480
Li, Z., Wang, Y., Wang, J., Tang, Z., Pounds, J. G., & Lin, Y. (2010) · Analytical Chemistry · doi:10.1021/ac101405a · Cited by 424
You, M., Lin, M., Gong, Y. M., Wang, S., Li, A., Ji, L., Zhao, H., Ling, K., Wen, T., Huang, Y., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b02466 · Cited by 335
Wu, X., Song, Y., Yan, X., Zhu, C., Ma, Y., Du, D., & Lin, Y. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.03.010 · Cited by 328
Multiplex Lateral Flow Immunoassay for Mycotoxin Determination
Song, S., Liu, N., Zhao, Z., Njumbe Ediage, E., Wu, S., Sun, C., De Saeger, S., & Wu, A. (2014) · Analytical Chemistry · doi:10.1021/ac500540z · Cited by 262
Li, J., & Macdonald, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.04.021 · Cited by 223
Ratajczak, K., & Stobiecka, M. (2020) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2019.115463 · Cited by 203
Point-of-Care Detection Devices for Food Safety Monitoring: Proactive Disease Prevention
Wu, M. Y.-C., Hsu, M., Chen, S., Hwang, D., Yen, T., & Cheng, C. (2017) · Trends in biotechnology · doi:10.1016/j.tibtech.2016.12.005 · Cited by 134
Fluorescent Polymersomes with Aggregation-Induced Emission
Zhang, N., Chen, H., Fan, Y., Zhou, L., Trépout, S., Guo, J., & Li, M. (2018) · ACS Nano · doi:10.1021/acsnano.8b01755 · Cited by 125
Lateral Flow Immunoassay Using Europium Chelate-Loaded Silica Nanoparticles as Labels
Xia, X., Xu, Y., Zhao, X., & Li, Q. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.114561 · Cited by 122
An AIE-based fluorescent test strip for the portable detection of gaseous phosgene
Xie, H., Wu, Y., Zeng, F., Chen, J., & Wu, S. (2017) · Chemical Communications · doi:10.1039/c7cc05313d · Cited by 99
Tokuoka, M., Seshime, Y., Fujii, I., Kitamoto, K., Takahashi, T., & Koyama, Y. (2008) · Fungal Genetics and Biology · doi:10.1016/j.fgb.2008.09.006 · Cited by 95
Sun, N., Su, K., Zhou, Z., Yu, Y., Tian, X., Wang, D., Zhao, X., Zhou, H., & Chen, C. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b01624 · Cited by 93
Self-citationLi, M., Lam, J. W. Y., Mahtab, F., Chen, S., Zhang, W., Hong, Y., Xiong, J. J., Zheng, Q., & Tang, B. Z. (2012) · Journal of Materials Chemistry B · doi:10.1039/c2tb00155a · Cited by 91
Self-citationTian, X., Zhu, M., Du, L., Wang, J., Fan, Z., Liu, J., Zhao, Y., & Nie, G. (2013) · Small · doi:10.1002/smll.201300817 · Cited by 81
Zhao, J., Dong, Z., Cui, H., Jin, H., & Wang, C. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b15921 · Cited by 63
Li, G., Xu, L., Wu, W., Wang, D., Jiang, J., Chen, X., Zhang, W., Poapolathep, S., Poapolathep, A., Zhang, Z., et al. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04290 · Cited by 53
Self-citationHu, X., Hu, R., Zhang, Z., Li, P., Zhang, Q., & Wang, M. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9626-5 · Cited by 51
Self-citationAIEgen-Based Polymer Nanocomposites for Imaging-Guided Photothermal Therapy
Wang, J., Li, J., Wang, L., Han, T., Wang, D., & Tang, B. Z. (2020) · ACS Applied Polymer Materials · doi:10.1021/acsapm.0c00712 · Cited by 46
Self-citationReconfigurable multiplexed point of Care System for monitoring type 1 diabetes patients
Márquez, A., Aymerich, J., Dei, M., Rodríguez‐Rodríguez, R., Vázquez‐Carrera, M., Pizarro‐Delgado, J., Giménez-Gómez, P., Merlos, Á., Terés, L., Serra-Graells, F., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.015 · Cited by 23
Feng, A., Jiang, F., Huang, G., & Liu, P. (2019) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2019.117446 · Cited by 17
Cited by
CRISPR‐Cas‐based detection for food safety problems: Current status, challenges, and opportunities
Li, Y., Man, S., Ye, S., Liu, G., & Ma, L. (2022) · Comprehensive Reviews in Food Science and Food Safety · doi:10.1111/1541-4337.13000 · Cited by 173
Metadata
- Authors
- Hu, X., Zhang, P., Wang, D., Jiang, J., Chen, X., Liu, Y., Zhang, Z., Tang, B. Z., & Li, P.
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2021-06
- Volume
- 182
- Pages
- 113188
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W3136218825
- Cited by
- 173
- References
- 30
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.