Abstract

Odorant discrimination mechanisms are based on the differential interactions between odorant molecules and olfactory receptors (ORs). Biohybrid sensors based on ORs described to date show selectivity towards specific versus non-specific binding of odorants, being unable to distinguish between specific ligands of different affinity. Here we disclose a method that enables odorant discrimination based on the modulation of the capacitive response of the receptor, which allows the differentiation of three high-affinity hOR1A1 agonists. We performed voltammetry and impedance measurements of the hOR1A1 receptor selectively immobilized on a gold electrode in the absence and presence of the agonists. Binding induces a decrease in the capacitive response of the receptor that is proportional to the ligand potency, reaching up to a 40% decrease for the cognate ligand dihydrojasmone, which is attributed to changes in the magnitude and orientation of the electric dipole in the receptor, thereby regulating its response to the applied electric field.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2024.117000

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 54

  1. Alfinito, 2016, Phys. Rev. E, 93, 10.1103/PhysRevE.93.062401 · DOI
  2. Alfinito, 2010, Sensor. Actuator. B Chem., 146, 554, 10.1016/j.snb.2010.01.008 · DOI
  3. Barbosa, 2018, Europe PMC funders group, Trends Biotechnol., 36, 1244, 10.1016/j.tibtech.2018.07.004 · DOI
  4. Belloir, 2017, Protein Expr. Purif., 129, 31, 10.1016/j.pep.2016.09.006 · DOI
  5. Ben Khemis, 2021, Int. J. Biol. Macromol., 28, 428, 10.1016/j.ijbiomac.2020.12.209 · DOI
  6. Billesbølle, 2023, Nature, 615, 742, 10.1038/s41586-023-05798-y · DOI
  7. Boccaccio, 2018, 113, 10.1007/978-1-4939-8609-5_9 · DOI
  8. Brenna, 2003, Tetrahedron Asymmetry, 14, 1, 10.1016/S0957-4166(02)00713-9 · DOI
  9. Buck, 1991, Cell, 65, 175, 10.1016/0092-8674(91)90418-X · DOI · Paper page
  10. Chakraborty, 2023, ChemPhysChem, 24, 10.1002/cphc.202200646 · DOI
  11. Chari, 2012, Proteins, 80, 1041, 10.1002/prot.24006 · DOI
  12. Chen, 2013, Biosens. Bioelectron., 48, 108, 10.1016/j.bios.2013.04.007 · DOI
  13. Choi, 2023, Nat. Commun., 14, 1
  14. de March, 2018, Angew. Chem. Int. Ed., 57, 4554, 10.1002/anie.201713065 · DOI
  15. Euch, 2019, Electrochim. Acta, 317, 509, 10.1016/j.electacta.2019.05.131 · DOI
  16. Feng, 2019, Elife, 8, 10.7554/eLife.41296 · DOI
  17. Francia, 2021, BMC Biol., 19, 174, 10.1186/s12915-021-01116-y · DOI
  18. Gateman, 2022, Curr. Opin. Electrochem., 36
  19. Goldsmith, 2011, ACS Nano, 5, 5408, 10.1021/nn200489j · DOI
  20. Heo, 2022, Proteins: structure, function and, Bioinformatics, 90, 1873
  21. Herrmann, T., Koeppel, C., Linn, J., Croy, I., Hummel, T., 123AD. Sci. Rep. 13, 10072. https://doi.org/10.1038/s41598-023-36783-0. · DOI
  22. Horcas, 2007, Rev. Sci. Instrum., 78, 29, 10.1063/1.2432410 · DOI
  23. Hou, 2007, Biosens. Bioelectron., 22, 1550, 10.1016/j.bios.2006.06.018 · DOI
  24. Huang, 2024, Talanta, 266
  25. Ikegami, 2020, Proc Natl Acad Sci U S A, 117, 2957, 10.1073/pnas.1915520117 · DOI
  26. Kang, 2011, Appl. Phys. Lett., 98
  27. Kazemi, 2015, Mater. Sci. Eng. C, 52, 151, 10.1016/j.msec.2015.03.058 · DOI
  28. Kwon, 2015, Nano Lett., 15, 6559, 10.1021/acs.nanolett.5b02286 · DOI
  29. Lagunas, 2022, Biosens. Bioelectron., 218, 10.1016/j.bios.2022.114755 · DOI
  30. Lee, 2012, Biomaterials, 33, 1722, 10.1016/j.biomaterials.2011.11.044 · DOI
  31. Lee, 2018, Sci. Rep., 8, 1
  32. Li, 2021, iScience, 24
  33. Lomize, 2012, Nucleic Acids Res., 40, D370, 10.1093/nar/gkr703 · DOI
  34. Lošdorfer Božič, 2017, Biophys. J., 113, 1454, 10.1016/j.bpj.2017.08.017 · DOI
  35. Maho, 2020, Biosens. Bioelectron., 159, 10.1016/j.bios.2020.112183 · DOI
  36. Maier, 2015, J. Chem. Theor. Comput., 11, 3696, 10.1021/acs.jctc.5b00255 · DOI
  37. Mei, 2018, J. Phys. Chem. C, 122, 24499, 10.1021/acs.jpcc.8b05241 · DOI
  38. Mulder, 1988, Electrochim. Acta, 33, 303, 10.1016/0013-4686(88)85021-7 · DOI
  39. Murugathas, 2019, ACS Appl. Mater. Interfaces, 11, 9530, 10.1021/acsami.8b19433 · DOI
  40. Okur, 2021, Angew. Chem. Int. Ed., 60, 3566, 10.1002/anie.202013227 · DOI · Paper page
  41. Pándy-Szekeres, 2018, Nucleic Acids Res., 46, D440, 10.1093/nar/gkx1109 · DOI
  42. Park, 2012, Nano Lett., 12, 5082, 10.1021/nl301714x · DOI
  43. Powers, 2023, Nat. Chem. Biol., 19, 805, 10.1038/s41589-022-01247-5 · DOI
  44. Reggiani, 2012, Nanoscale Res. Lett., 7, 1, 10.1186/1556-276X-7-340 · DOI
  45. Saito, 2009, Sci. Signal., 2, 10.1126/scisignal.2000016 · DOI
  46. Sharma, 2013, Anal. Chem., 85, 2472, 10.1021/ac3035426 · DOI
  47. Søndergaard, 2011, J. Chem. Theor. Comput., 7, 2284, 10.1021/ct200133y · DOI
  48. Wasilewski, 2022, TrAC, Trends Anal. Chem., 150, 10.1016/j.trac.2022.116599 · DOI
  49. Weaver, 2023, Biosens. Bioelectron., 224, 10.1016/j.bios.2022.115014 · DOI
  50. Webb, 2016, Curr Protoc Bioinformatics, 54, 10.1002/cpbi.3 · DOI
  51. Xuejun, 2013, Protein Cell, 4, 747, 10.1007/s13238-013-3073-2 · DOI
  52. Yang, 2017, ACS Nano, 11, 11847, 10.1021/acsnano.7b04992 · DOI
  53. Yang, 2023, Trends Cell Biol., 33, 463, 10.1016/j.tcb.2022.09.005 · DOI
  54. Yoon, 2009, Angew. Chem. Int. Ed., 48, 2755, 10.1002/anie.200805171 · DOI

Metadata

Authors
Lagunas, A., Belloir, C., Lalis, M., Briand, L., Topin, J., Gorostiza, P., & Samitier, J.
Affiliations
  • Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES)
  • Centre National de la Recherche Scientifique (FR)
  • Université Côte d'Azur (FR)
  • Institució Catalana de Recerca i Estudis Avançats (ES)
  • Instituto de Salud Carlos III (ES)
Corresponding author
Lagunas, Anna
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2025-03
Volume
271
Pages
117000
ISSN
0956-5663 (ISSN-L)
OpenAlex
W4404907120
Cited by
6
References
1
Citations by year
2026: 3 · 2025: 3
FWCI
0.62
Type
journal article
Language
en
Open access
Locations
  • Biosensors and Bioelectronics (publishedVersion)
  • SSRN Electronic Journal (acceptedVersion)
  • ChemRxiv (acceptedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, cc-by-nc-nd)
  • HAL (submittedVersion)
Funders
  • Centres de Recerca de Catalunya
  • Agence Nationale de la Recherche (ANR-18-CE30-0006)
  • Generalitat de Catalunya (2021SGR-01545)
  • Fondation de France
  • Instituto de Salud Carlos III
  • European Regional Development Fund
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
Keywords
olfactory receptors, odor discrimination, ligand discrimination, capacitive response, gold electrode, dihydrojasmone, electric dipole, receptor immobilization, impedance sensing, voltammetry, ligand potency
MeSH terms
Electrodes, Gold, Humans, Ligands, Odorants, Biosensing Techniques, Receptors, Odorant, Electric Capacitance, Electrochemical Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review