The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ligand discrimination in hOR1A1 based on the capacitive response
Open accessPublished version of a preprint
Abstract
Odorant discrimination mechanisms are based on the differential interactions between odorant molecules and olfactory receptors (ORs). Biohybrid sensors based on ORs described to date show selectivity towards specific versus non-specific binding of odorants, being unable to distinguish between specific ligands of different affinity. Here we disclose a method that enables odorant discrimination based on the modulation of the capacitive response of the receptor, which allows the differentiation of three high-affinity hOR1A1 agonists. We performed voltammetry and impedance measurements of the hOR1A1 receptor selectively immobilized on a gold electrode in the absence and presence of the agonists. Binding induces a decrease in the capacitive response of the receptor that is proportional to the ligand potency, reaching up to a 40% decrease for the cognate ligand dihydrojasmone, which is attributed to changes in the magnitude and orientation of the electric dipole in the receptor, thereby regulating its response to the applied electric field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly accurate protein structure prediction with AlphaFold
Jumper, J., Evans, R., Pritzel, A., Green, T., Figurnov, M., Ronneberger, O., Tunyasuvunakool, K., Bates, R., Žídek, A., Potapenko, A., et al. (2021) · Nature · doi:10.1038/s41586-021-03819-2 · Cited by 43,764
Flagged first, then by citations
Research works printed but not linked: 54
- Alfinito, 2016, Phys. Rev. E, 93, 10.1103/PhysRevE.93.062401 · DOI
- Alfinito, 2010, Sensor. Actuator. B Chem., 146, 554, 10.1016/j.snb.2010.01.008 · DOI
- Barbosa, 2018, Europe PMC funders group, Trends Biotechnol., 36, 1244, 10.1016/j.tibtech.2018.07.004 · DOI
- Belloir, 2017, Protein Expr. Purif., 129, 31, 10.1016/j.pep.2016.09.006 · DOI
- Ben Khemis, 2021, Int. J. Biol. Macromol., 28, 428, 10.1016/j.ijbiomac.2020.12.209 · DOI
- Billesbølle, 2023, Nature, 615, 742, 10.1038/s41586-023-05798-y · DOI
- Boccaccio, 2018, 113, 10.1007/978-1-4939-8609-5_9 · DOI
- Brenna, 2003, Tetrahedron Asymmetry, 14, 1, 10.1016/S0957-4166(02)00713-9 · DOI
- Buck, 1991, Cell, 65, 175, 10.1016/0092-8674(91)90418-X · DOI · Paper page
- Chakraborty, 2023, ChemPhysChem, 24, 10.1002/cphc.202200646 · DOI
- Chari, 2012, Proteins, 80, 1041, 10.1002/prot.24006 · DOI
- Chen, 2013, Biosens. Bioelectron., 48, 108, 10.1016/j.bios.2013.04.007 · DOI
- Choi, 2023, Nat. Commun., 14, 1
- de March, 2018, Angew. Chem. Int. Ed., 57, 4554, 10.1002/anie.201713065 · DOI
- Euch, 2019, Electrochim. Acta, 317, 509, 10.1016/j.electacta.2019.05.131 · DOI
- Feng, 2019, Elife, 8, 10.7554/eLife.41296 · DOI
- Francia, 2021, BMC Biol., 19, 174, 10.1186/s12915-021-01116-y · DOI
- Gateman, 2022, Curr. Opin. Electrochem., 36
- Goldsmith, 2011, ACS Nano, 5, 5408, 10.1021/nn200489j · DOI
- Heo, 2022, Proteins: structure, function and, Bioinformatics, 90, 1873
- Herrmann, T., Koeppel, C., Linn, J., Croy, I., Hummel, T., 123AD. Sci. Rep. 13, 10072. https://doi.org/10.1038/s41598-023-36783-0. · DOI
- Horcas, 2007, Rev. Sci. Instrum., 78, 29, 10.1063/1.2432410 · DOI
- Hou, 2007, Biosens. Bioelectron., 22, 1550, 10.1016/j.bios.2006.06.018 · DOI
- Huang, 2024, Talanta, 266
- Ikegami, 2020, Proc Natl Acad Sci U S A, 117, 2957, 10.1073/pnas.1915520117 · DOI
- Kang, 2011, Appl. Phys. Lett., 98
- Kazemi, 2015, Mater. Sci. Eng. C, 52, 151, 10.1016/j.msec.2015.03.058 · DOI
- Kwon, 2015, Nano Lett., 15, 6559, 10.1021/acs.nanolett.5b02286 · DOI
- Lagunas, 2022, Biosens. Bioelectron., 218, 10.1016/j.bios.2022.114755 · DOI
- Lee, 2012, Biomaterials, 33, 1722, 10.1016/j.biomaterials.2011.11.044 · DOI
- Lee, 2018, Sci. Rep., 8, 1
- Li, 2021, iScience, 24
- Lomize, 2012, Nucleic Acids Res., 40, D370, 10.1093/nar/gkr703 · DOI
- Lošdorfer Božič, 2017, Biophys. J., 113, 1454, 10.1016/j.bpj.2017.08.017 · DOI
- Maho, 2020, Biosens. Bioelectron., 159, 10.1016/j.bios.2020.112183 · DOI
- Maier, 2015, J. Chem. Theor. Comput., 11, 3696, 10.1021/acs.jctc.5b00255 · DOI
- Mei, 2018, J. Phys. Chem. C, 122, 24499, 10.1021/acs.jpcc.8b05241 · DOI
- Mulder, 1988, Electrochim. Acta, 33, 303, 10.1016/0013-4686(88)85021-7 · DOI
- Murugathas, 2019, ACS Appl. Mater. Interfaces, 11, 9530, 10.1021/acsami.8b19433 · DOI
- Okur, 2021, Angew. Chem. Int. Ed., 60, 3566, 10.1002/anie.202013227 · DOI · Paper page
- Pándy-Szekeres, 2018, Nucleic Acids Res., 46, D440, 10.1093/nar/gkx1109 · DOI
- Park, 2012, Nano Lett., 12, 5082, 10.1021/nl301714x · DOI
- Powers, 2023, Nat. Chem. Biol., 19, 805, 10.1038/s41589-022-01247-5 · DOI
- Reggiani, 2012, Nanoscale Res. Lett., 7, 1, 10.1186/1556-276X-7-340 · DOI
- Saito, 2009, Sci. Signal., 2, 10.1126/scisignal.2000016 · DOI
- Sharma, 2013, Anal. Chem., 85, 2472, 10.1021/ac3035426 · DOI
- Søndergaard, 2011, J. Chem. Theor. Comput., 7, 2284, 10.1021/ct200133y · DOI
- Wasilewski, 2022, TrAC, Trends Anal. Chem., 150, 10.1016/j.trac.2022.116599 · DOI
- Weaver, 2023, Biosens. Bioelectron., 224, 10.1016/j.bios.2022.115014 · DOI
- Webb, 2016, Curr Protoc Bioinformatics, 54, 10.1002/cpbi.3 · DOI
- Xuejun, 2013, Protein Cell, 4, 747, 10.1007/s13238-013-3073-2 · DOI
- Yang, 2017, ACS Nano, 11, 11847, 10.1021/acsnano.7b04992 · DOI
- Yang, 2023, Trends Cell Biol., 33, 463, 10.1016/j.tcb.2022.09.005 · DOI
- Yoon, 2009, Angew. Chem. Int. Ed., 48, 2755, 10.1002/anie.200805171 · DOI
Metadata
- Authors
- Lagunas, A., Belloir, C., Lalis, M., Briand, L., Topin, J., Gorostiza, P., & Samitier, J.
- Affiliations
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES)
- Centre National de la Recherche Scientifique (FR)
- Université Côte d'Azur (FR)
- Institució Catalana de Recerca i Estudis Avançats (ES)
- Instituto de Salud Carlos III (ES)
- Corresponding author
- Lagunas, Anna
- ORCID
- Venue
- Biosensors and Bioelectronics
- Publisher
- Elsevier BV
- Published
- 2025-03
- Volume
- 271
- Pages
- 117000
- ISSN
- 0956-5663 (ISSN-L)
- OpenAlex
- W4404907120
- Cited by
- 6
- References
- 1
- Citations by year
- 2026: 3 · 2025: 3
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- green
- doi.org
- Licence
- Locations
- Biosensors and Bioelectronics (publishedVersion)
- SSRN Electronic Journal (acceptedVersion)
- ChemRxiv (acceptedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- HAL (submittedVersion, cc-by-nc-nd)
- HAL (submittedVersion)
- Funders
- Centres de Recerca de Catalunya
- Agence Nationale de la Recherche (ANR-18-CE30-0006)
- Generalitat de Catalunya (2021SGR-01545)
- Fondation de France
- Instituto de Salud Carlos III
- European Regional Development Fund
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Keywords
- olfactory receptors, odor discrimination, ligand discrimination, capacitive response, gold electrode, dihydrojasmone, electric dipole, receptor immobilization, impedance sensing, voltammetry, ligand potency
- MeSH terms
- Electrodes, Gold, Humans, Ligands, Odorants, Biosensing Techniques, Receptors, Odorant, Electric Capacitance, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review