The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Non-invasive axial loading of mouse tibiae increases cortical bone formation and modifies trabecular organization: A new model to study cortical and cancellous compartments in a single loaded element
Abstract
Systematic study of bones' responses to loading requires simple non-invasive models in appropriate experimental animals where the applied load is controllable and the changes in bone quantifiable. Herein, we validate a model for applying axial loads, non-invasively to murine tibiae. This allows the effects of mechanical loading in both cancellous and cortical bone to be determined within a single bone in which genetic, neuronal and functional influences can also be readily manipulated. Using female C57Bl/J6 mice, peak strains at the tibial mid-shaft were measured during walking (<300 micro epsilon tension) and jumping (<600 micro epsilon compression) with single longitudinally oriented strain gauges attached to the bone's lateral and medial surfaces. Identically positioned gauges were also used to determine, for calibration, the strains engendered by external applied compressive tibial loading between the flexed knee and ankle ex vivo. Applied loads between 5 and 13 N produced strains of 1150-2000 micro epsilon on the lateral surface, and in vivo repetitions of these loads on alternate days for 2 weeks produced significant load magnitude-related increases in cortical bone formation that were similar in mice at 8, 12 and 20 weeks of age. Micro-CT scans showed that loading significantly increases trabecular bone volume in 8 week old mice, but modifies trabecular organization with decreases in trabecular bone volume in 12 and 20 week old mice. This model for loading the tibia has several advantages over other approaches, including scope to study the effects of loading in cancellous as well as cortical bone, against a background of either disuse or of treatment with osteotropic agents within a single bone in normal, mutant and transgenic mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verborgt, O., Gibson, G. J., & Schaffler, M. B. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.1.60 · Cited by 731
Cited by
Molecular mechanosensors in osteocytes
Qin, L., Liu, W., Cao, H., & Xiao, G. (2020) · Bone Research · doi:10.1038/s41413-020-0099-y · Cited by 484
Morrell, A. E., Brown, G. N., Robinson, S. T., Sattler, R. L., Baik, A. D., Zhen, G., Cao, X., Bonewald, L. F., Jin, W., Kam, L. C., et al. (2018) · Bone Research · doi:10.1038/s41413-018-0007-x · Cited by 184
Beller, G., Belavý, D. L., Sun, L., Armbrecht, G., Alexandre, C., & Felsenberg, D. (2011) · Bone · doi:10.1016/j.bone.2011.06.021 · Cited by 60
Metadata
- Authors
- De Souza, R. L., Matsuura, M., Eckstein, F., Rawlinson, S. C. F., Lanyon, L. E., & Pitsillides, A. A.
- Venue
- Bone
- Publisher
- Elsevier BV
- Published
- 2005-12
- Volume
- 37
- Issue
- 6
- Pages
- 810-818
- ISSN
- 1873-2763 (ISSN-L)
- 8756-3282
- OpenAlex
- W2025398368
- Cited by
- 378
- References
- 1
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-invasive axial loading of mouse tibiae increases cortical bone formation and modifies trabecular organization: A new model to study cortical and cancellous compartments in a single loaded element. https://app.cochat.ai/papers/10.1016/j.bone.2005.07.022
- The paper
- De Souza, R. L., Matsuura, M., Eckstein, F., Rawlinson, S. C. F., Lanyon, L. E., & Pitsillides, A. A. (2005). Non-invasive axial loading of mouse tibiae increases cortical bone formation and modifies trabecular organization: A new model to study cortical and cancellous compartments in a single loaded element. Bone. https://doi.org/10.1016/j.bone.2005.07.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.