Cited by 274Bone health and osteoporosis researchBody Composition Measurement TechniquesForensic Anthropology and Bioarchaeology Studies

DXA in vivo BMD methodology: An erroneous and misleading research and clinical gauge of bone mineral status, bone fragility, and bone remodelling

Bolotin, H.H.·2007·Bone

Abstract

The seemingly unqualified reliance and near-universal dependence upon in vivo dual-energy X-ray absorptiometric (DXA) methodology to provide accurate, quantitative, and meaningful in vivo (in situ cadaveric) bone mineral areal density ("BMD") determinations are proven to be unwarranted and misplaced. The underlying systematics of sizable, inherently unavoidable and un-correctable inaccuracies in the DXA output values of in vivo "BMD" are shown to be quantitatively consistent with being the root cause of unreliable, misdirected, and misinterpreted aspects of consensual knowledge of bone fragility, osteoporotic diagnostics/prognostics, and remodelling therapies. The "BMD" label that DXA ascribes to the output values of in vivo (in situ cadaveric) bone densitometry scans is shown to be a misnomer and an erroneous and invalid measure of bone mineral material. The DXA-derived "BMD" value does not correctly represent the areal density of bone mineral material, as it is contaminated by sizable, unavoidable, inextricable, independent soft tissue contributions. Due to intra- and extra-osseous soft tissue X-ray absorptiometric effects, it is unknown (and unknowable) exactly what DXA in vivo "BMD" is a measure of in any given case, or what proportion of the "BMD" value represents the actual bone mineral material areal density present in the DXA scan region of interest (ROI) of any predominantly trabecular bone-site (e.g., lumbar vertebrae, proximal femora). This inherent fundamental def…

Integrity signals

Registry

Crossref · 10.1016/j.bone.2007.02.022

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bolotin, H. H.
Affiliations
RMIT University (AU)
Corresponding author
Bolotin, H.H.
Venue
Bone
Publisher
Elsevier BV
Published
2007-07
Volume
41
Issue
1
Pages
138-154
ISSN
  • 1873-2763 (ISSN-L)
  • 8756-3282
OpenAlex
W2170424332
Cited by
274
References
1
Citations by year
2026: 10 · 2025: 14 · 2024: 17 · 2023: 19 · 2022: 20 · 2021: 11 · 2020: 24 · 2019: 13 · 2018: 11 · 2017: 13 · 2016: 14 · 2015: 12 · 2014: 11 · 2013: 14 · 2012: 11
FWCI
15.60
Type
journal article
Language
en
Open access
closed
Locations
  • Bone (publishedVersion)
  • PubMed (publishedVersion)
  • RMIT Research Repository (RMIT University Library) (submittedVersion)
  • Figshare (submittedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Social Sciences › Arts and Humanities › Archeology › Forensic Anthropology and Bioarchaeology Studies
Keywords
dual-energy X-ray absorptiometry, bone mineral density, measurement error, bone fragility, osteoporosis diagnosis, bone remodeling, fracture risk, trabecular bone, bone mineral status
MeSH terms
Biomechanical Phenomena, Bone and Bones, Cross-Sectional Studies, Diagnostic Errors, Female, Humans, Osteoporosis, Prospective Studies, Tomography, X-Ray Computed, Reproducibility of Results, Absorptiometry, Photon, Bone Density, Bone Remodeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review