Effects of trabecular type and orientation on microdamage susceptibility in trabecular bone
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Trabecular architecture becomes more rod-like and anisotropic in osteoporotic and aging trabecular bone. In order to address the effects of trabecular type and orientation on trabecular bone damage mechanics, microstructural finite element modeling was used to identify the yielded tissue in ten bovine tibial trabecular bone samples compressed to 1.2% on-axis apparent strain. The yielded tissue was mapped onto individual trabeculae identified by an Individual Trabeculae Segmentation (ITS) technique, and the distribution of the predicted yielding among trabecular types and orientations was compared to the experimentally measured microdamage. Although most of the predicted yielded tissue was found in longitudinal plates (73 ± 11%), the measured microcrack density was positively correlated with the proportion of the yielded tissue in longitudinal rods (R2 = 0.52, p = 0.02), but not in rods of other directions or plates. The overall fraction of rods and the fractions of rods along the longitudinal and transverse axes were also correlated with the measured microcrack density. In contrast, diffuse damage area did not correlate with any of these quantities. These results agree with the findings that both in vitro and in vivo microcrack density is correlated with Structure Model Index (SMI), and are also consistent with decreased energy to failure in more rod-like trabecular bone. Together the results suggest that bending or buckling deformations of rod-like trabeculae may make trabecular structures more susceptible to microdamage formation. Moreover, while simple strain-based tissue yield criteria may account for macroscopic yielding, they may not be suitable for identifying damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142 · cited 1×
“41%, respectively [35].”
Self-citationBiomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961 · cited 1×
“Trabecular tissue loss is accompanied by topological changes, such as thinning of trabeculae [2] and the conversion of trabecular plates to rods [3], such that tissue loss and architectural changes are linked.”
Backgroundvan Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865 · cited 1×
“The trabecular tissue was modeled as a homogenous isotropic material with a specimen-specific back-calculated tissue modulus [34] and a Poisson’s ratio of 0.”
MethodInfluence of nonenzymatic glycation on biomechanical properties of cortical bone
Vashishth, D., Gibson, G. J., Khoury, J. I., Schaffler, M. B., Kimura, J., & Fyhrie, D. P. (2001) · Bone · doi:10.1016/s8756-3282(00)00434-8 · Cited by 525 · cited 1×
“Nonenzymatic glycation results in increased collagen cross-linking and increases trabecular bone damage susceptibility [14,43,45], although microdamage itself also affects measured cross-links [15].”
BackgroundFracture in human cortical bone: local fracture criteria and toughening mechanisms
Nalla, R. K., Stölken, J. S., Kinney, J. H., & Ritchie, R. O. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.07.010 · Cited by 260 · cited 1×
“Crack initiation and arrest sites include osteocyte lacunae and lamellar interfaces [16,17].”
BackgroundTrabecular bone microdamage and microstructural stresses under uniaxial compression
Nagaraja, S., Couse, T. L., & Guldberg, R. E. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.013 · Cited by 220 · cited 3×
“However, the apparent strains that result in microcrack formation [18,27,36] and large bending deformation of rods generally exceed 1%, which is unlikely to occur in vivo.”
BackgroundLiu, X. S., Sajda, P., Saha, P. K., Wehrli, F. W., & Guo, X. E. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.060716 · Cited by 207 · cited 2×
“Using this technique, plates have been shown to have a greater contribution to the elastic stiffness of trabecular bone than rods [21], and axially aligned trabeculae were found to provide the main resistance to axial loading [22].”
MethodSelf-citationMicroarchitecture Influences Microdamage Accumulation in Human Vertebral Trabecular Bone
Arlot, M. E., Burt-Pichat, B., Roux, J.-P., Vashishth, D., Bouxsein, M. L., & Delmas, P. D. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080517 · Cited by 89
Damage in trabecular bone at small strains
Morgan, E., Yeh, O., & Keaveny, T. (2005) · European Journal of Morphology · doi:10.1080/09243860500095273 · Cited by 59 · cited 1×
“However, microdamage accumulation beyond the bone’s capacity to repair, especially in osteoporotic or aging bone, can adversely affect the mechanical properties of bone [8,9].”
BackgroundTang, S. Y., & Vashishth, D. (2007) · Bone · doi:10.1016/j.bone.2006.10.031 · Cited by 59 · cited 1×
“However, microdamage accumulation beyond the bone’s capacity to repair, especially in osteoporotic or aging bone, can adversely affect the mechanical properties of bone [8,9].”
Background
Cited by
Shi, X., Sherry Liu, X., Wang, X., Edward Guo, X., & Niebur, G. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.05.032 · Cited by 45
“Since yielding in rods is directly correlated to increased microcrack density (Shi et al., 2010), the transition of horizontal trabeculae to a more rod-like morphology in osteoporotic bone may make the whole structure more vulnerable to damage from unusual or off-axis loading.”
BackgroundSelf-citationLambers, F. M., Bouman, A. R., Tkachenko, E. V., Keaveny, T. M., & Hernandez, C. J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.10.011 · Cited by 36
Goff, M. G., Lambers, F. M., Sorna, R. M., Keaveny, T. M., & Hernandez, C. J. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.10.023 · Cited by 20
“…demonstrating that the total volume of microdamage generated is correlated with the volume of failed tissue predicted by finite element models (Shi et al., 2010; Yeni et al., 2003) or that the locations of “severe” microdamage display greater than average local tissue stresses (Nagaraja et…”
Background
Metadata
- Authors
- Shi, X., Liu, X. S., Wang, X., Guo, X. E., & Niebur, G. L.
- Venue
- Bone
- Publisher
- Elsevier BV
- Published
- 2010-05
- Volume
- 46
- Issue
- 5
- Pages
- 1260-1266
- ISSN
- 1873-2763 (ISSN-L)
- 8756-3282
- OpenAlex
- W2114296553
- Cited by
- 64
- References
- 10
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of trabecular type and orientation on microdamage susceptibility in trabecular bone. https://app.cochat.ai/papers/10.1016/j.bone.2010.02.005
- The paper
- Shi, X., Liu, X. S., Wang, X., Guo, X. E., & Niebur, G. L. (2010). Effects of trabecular type and orientation on microdamage susceptibility in trabecular bone. Bone. https://doi.org/10.1016/j.bone.2010.02.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.