CoChat

Human trabecular bone microarchitecture can be assessed independently of density with second generation HR-pQCT

Open access
Manske, Sarah L., Zhu, Ying, Sandino, Clara, Boyd, Steven K. · 2015 · Bone
Cited by 171

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The second generation HR-pQCT scanner (XtremeCTII, Scanco Medical) can assess human bone microarchitecture of peripheral limbs with a 61 μm nominal isotropic voxel size. This is a marked improvement from the first generation HR-pQCT that had a nominal isotropic voxel size of 82 μm, which is at the limit to accurately determine the thickness of individual human trabeculae. We sought to determine the accuracy of a direct morphometric approach to measure trabecular bone microarchitecture with three-dimensional morphological techniques using second generation HR-pQCT, and to compare this with the approach currently applied by the first generation HR-pQCT scanner based on derived indices using ex vivo scans of human cadaveric radii. We also compared images acquired and resampled to mimic the first generation HR-pQCT with those obtained directly from the first generation HR-pQCT. We evaluated 20 human cadaveric radii and a micro-CT performance phantom using the first (XtremeCT, Scanco Medical) and second generation HR-pQCT scanner (XtremeCTII) and compared a patient evaluation (XCTII, 61 μm) with a high resolution ex vivo protocol (HR, 30μm). We generated 82 μm scans of the same specimens to mimic a first-generation HR-pQCT evaluation (XCTIM, 82 μm) and compared these with a first-generation patient evaluation (XCTI, 82 μm). A standard structural extraction approach was applied to both XCTII and HR evaluations for assessment of bone volume fraction (BV/TV), and a distance transform was used to assess trabecular number (Tb.N), trabecular thickness (Tb.Th) and trabecular separation (Tb.Sp). For XCTI and XCTIM evaluations we followed the manufacturer's standard procedure and assessed bone mineral density (BMD), Tb.N with a distance transform, and then derived bone volume ratio (BV/TV(d)), trabecular thickness (Tb.Th(d)) and separation (Tb.Sp(d)). The spatial resolution (10% MTF) was 142.2 μm for XCTI, 108.9 μm for XCTIM, 95.2μm for XCTII, and 55.9 μm for HR. XCTI and XCTIM provided strongly associated measurements of BMD and microarchitectural outcomes (R(2)>0.97), however there were systematic differences in all outcomes. The Tb.N was highly associated with HR by both XCTII (R(2)=0.93, mean error=-0.12 mm(-1)) and XCTIM (R(2)=0.98, mean error=0.25 mm(-1)). Also, both XCTII (R(2)=0.99, mean error=0.20mm) and XCTIM (R(2)=0.99, mean error=-0.18 mm) had Tb.Sp that were strongly related to HR. For Tb.Th, the XCTII was more closely related to HR (R(2)=0.94, mean error=0.04 mm) than the relatively weak XCTIM (R(2)=0.16, mean error=- 0.076 mm). We found that trabecular microarchitecture assessment following the XCTII direct morphometric approach accurately represented the HR data. In particular, the measure of Tb.Th was markedly improved for XCTII compared with the derived approach of XCTIM. These data support the application of analysis techniques in HR-pQCT that are analogous to those traditionally used for micro-CT to assess trabecular microarchitecture. The decreased dependence of structural outcomes on density provides a new, important opportunity to monitor human in vivo bone microarchitecture.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bone.2015.06.006

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Manske, S. L., Zhu, Y., Sandino, C., & Boyd, S. K.
Venue
Bone
Publisher
Elsevier BV
Published
2015-10
Volume
79
Pages
213-221
ISSN
  • 1873-2763 (ISSN-L)
  • 8756-3282
OpenAlex
W1803711505
Cited by
171
References
3
FWCI
12.93
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.