Lipid Mixing and Content Release in Single-Vesicle, SNARE-Driven Fusion Assay with 1–5 ms Resolution
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A single-vesicle, fluorescence-based, SNARE-driven fusion assay enables simultaneous measurement of lipid mixing and content release with 5 ms/frame, or even 1 ms/frame, time resolution. The v-SNARE vesicles, labeled with lipid and content markers of different color, dock and fuse with a planar t-SNARE bilayer supported on glass. A narrow (<5 ms duration), intense spike of calcein fluorescence due to content release and dequenching coincides with inner-leaflet lipid mixing within 10 ms. The spike provides more sensitive detection of productive hemifusion events than do lipid labels alone. Consequently, many fast events previously thought to be prompt, full fusion events are now reclassified as productive hemifusion. Both full fusion and hemifusion occur with a time constant of 5-10 ms. At 60% phosphatidylethanolamine lipid composition, productive and dead-end hemifusion account for 65% of all fusion events. However, quantitative analysis shows that calcein is released into the space above the bilayer (vesicle bursting), rather than the thin aqueous space between the bilayer and glass. Evidently, at the instant of inner-leaflet mixing, flattening of the vesicle increases the internal pressure beyond the bursting point. This may be related to in vivo observations suggesting that membrane lysis often competes with membrane fusion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Südhof, T. C. (2004) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.26.041002.131412 · Cited by 2,547
Crystal structure of a SNARE complex involved in synaptic exocytosis at 2.4 Å resolution
Sutton, R. B., Fasshauer, D., Jahn, R., & Brunger, A. T. (1998) · Nature · doi:10.1038/26412 · Cited by 2,417
Chanturiya, A., Chernomordik, L. V., & Zimmerberg, J. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.26.14423 · Cited by 201 · cited 1×
“In a more recent study, researchers simultaneously monitored hemifusion and content release by following lipid and content labels (27).”
BackgroundInfluential
Cited by
Molecular machines governing exocytosis of synaptic vesicles
Jahn, R., & Fasshauer, D. (2012) · Nature · doi:10.1038/nature11320 · Cited by 970
The delivery of therapeutic oligonucleotides
Juliano, R. L. (2016) · Nucleic Acids Research · doi:10.1093/nar/gkw236 · Cited by 854
Piffoux, M., Silva, A. K. A., Wilhelm, C., Gazeau, F., & Tareste, D. (2018) · ACS Nano · doi:10.1021/acsnano.8b02053 · Cited by 456
The Membrane Fusion Enigma: SNAREs, Sec1/Munc18 Proteins, and Their Accomplices—Guilty as Charged?
Rizo, J., & Südhof, T. C. (2012) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-101011-155818 · Cited by 386
Wickner, W. (2010) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-100109-104131 · Cited by 280
Metadata
- Authors
- Wang, T., Smith, E. A., Chapman, E. R., & Weisshaar, J. C.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2009-05
- Volume
- 96
- Issue
- 10
- Pages
- 4122-4131
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1984974677
- Cited by
- 75
- References
- 3
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.