The DOI matches its Crossref record.
Homo-FRET Imaging Enables Quantification of Protein Cluster Sizes with Subcellular Resolution
Open accessOverview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
FRET as a biomolecular research tool — understanding its potential while avoiding pitfalls
Algar, W. R., Hildebrandt, N., Vogel, S. S., & Medintz, I. L. (2019) · Nature Methods · doi:10.1038/s41592-019-0530-8 · Cited by 609
Advanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C. (2012) · Molecules · doi:10.3390/molecules17044047 · Cited by 557
A Guide to Fluorescent Protein FRET Pairs
Bajar, B., Wang, E., Zhang, S., Lin, M., & Chu, J. (2016) · Sensors · doi:10.3390/s16091488 · Cited by 463
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Fluorescence lifetime imaging microscopy in life sciences
Borst, J. W., & Visser, A. J. W. G. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/102002 · Cited by 168
Imaging Approaches for the Study of Metabolism in Real Time Using Genetically Encoded Reporters
Chandris, P., Giannouli, C. C., & Panayotou, G. (2022) · Frontiers in Cell and Developmental Biology · doi:10.3389/fcell.2021.725114 · Cited by 19
“Homo-FRET analysis is based on anisotropy measurements, requires specialized instrumentation and although it can be used for analyzing molecular dynamics and signaling events (Bader et al., 2009; Warren et al., 2015), it is not the method of choice when it comes to metabolite analysis.”
Metadata
- Authors
- Bader, A. N., Hofman, E. G., Voortman, J., van Bergen en Henegouwen, P. M. P., & Gerritsen, H. C.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 97
- Issue
- 9
- Pages
- 2613-2622
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2135897043
- Cited by
- 160
- References
- 0
- FWCI
- 6.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.