Coaligned Dual-Channel STED Nanoscopy and Molecular Diffusion Analysis at 20 nm Resolution
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We report on a fiber laser-based stimulated emission-depletion microscope providing down to ∼20 nm resolution in raw data images as well as 15-19 nm diameter probing areas in fluorescence correlation spectroscopy. Stimulated emission depletion pulses of nanosecond duration and 775 nm wavelength are used to silence two fluorophores simultaneously, ensuring offset-free colocalization analysis. The versatility of this superresolution method is exemplified by revealing the octameric arrangement of Xenopus nuclear pore complexes and by quantifying the diffusion of labeled lipid molecules in artificial and living cell membranes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence microscopy with diffraction resolution barrier broken by stimulated emission
Klar, T. A., Jakobs, S., Dyba, M., Egner, A., & Hell, S. W. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.15.8206 · Cited by 1,869 · cited 2×
“029 Since its first demonstration in (live) cell imaging (1), stimulated emission depletion (STED) fluorescence microscopy has been realized in many variants.”
Self-citationDirect observation of the nanoscale dynamics of membrane lipids in a living cell
Eggeling, C., Ringemann, C., Medda, R., Schwarzmann, G., Sandhoff, K., Polyakova, S., Belov, V. N., Hein, B., von Middendorff, C., Schönle, A., et al. (2009) · Nature · doi:10.1038/nature07596 · Cited by 1,520
Self-citationSchwille, P., Meyer-Almes, F. J., & Rigler, R. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78833-7 · Cited by 817
Sharper low-power STED nanoscopy by time gating
Vicidomini, G., Moneron, G., Han, K. Y., Westphal, V., Ta, H., Reuss, M., Engelhardt, J., Eggeling, C., & Hell, S. W. (2011) · Nature Methods · doi:10.1038/nmeth.1624 · Cited by 423
Self-citationLöschberger, A., van de Linde, S., Dabauvalle, M.-C., Rieger, B., Heilemann, M., Krohne, G., & Sauer, M. (2012) · Journal of Cell Science · doi:10.1242/jcs.098822 · Cited by 306
Two-Color Far-Field Fluorescence Nanoscopy
Donnert, G., Keller, J., Wurm, C. A., Rizzoli, S. O., Westphal, V., Schönle, A., Jahn, R., Jakobs, S., Eggeling, C., & Hell, S. W. (2007) · Biophysical Journal · doi:10.1529/biophysj.107.104497 · Cited by 256
Self-citationMueller, V., Ringemann, C., Honigmann, A., Schwarzmann, G., Medda, R., Leutenegger, M., Polyakova, S., Belov, V. N., Hell, S. W., & Eggeling, C. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.09.006 · Cited by 253
Self-citationSimultaneous multi-lifetime multi-color STED imaging for colocalization analyses
Bückers, J., Wildanger, D., Vicidomini, G., Kastrup, L., & Hell, S. W. (2011) · Optics Express · doi:10.1364/oe.19.003130 · Cited by 225
Self-citationAuksorius, E., Boruah, B. R., Dunsby, C., Lanigan, P. M. P., Kennedy, G., Neil, M. A. A., & French, P. M. W. (2008) · Optics Letters · doi:10.1364/ol.33.000113 · Cited by 190
Time-gating improves the spatial resolution of STED microscopy
Moffitt, J. R., Osseforth, C., & Michaelis, J. (2011) · Optics Express · doi:10.1364/oe.19.004242 · Cited by 159
Cited by
Super-resolution microscopy demystified
Schermelleh, L., Ferrand, A., Huser, T., Eggeling, C., Sauer, M., Biehlmaier, O., & Drummen, G. P. C. (2019) · Nature Cell Biology · doi:10.1038/s41556-018-0251-8 · Cited by 1,211
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Self-citationFluorogenic probes for live-cell imaging of the cytoskeleton
Lukinavičius, G., Reymond, L., D'Este, E., Masharina, A., Göttfert, F., Ta, H., Güther, A., Fournier, M., Rizzo, S., Waldmann, H., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2972 · Cited by 820
Self-citationSTED super-resolved microscopy
Vicidomini, G., Bianchini, P., & Diaspro, A. (2018) · Nature Methods · doi:10.1038/nmeth.4593 · Cited by 717
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
The 2015 super-resolution microscopy roadmap
Hell, S. W., Sahl, S. J., Bates, M., Zhuang, X., Heintzmann, R., Booth, M. J., Bewersdorf, J., Shtengel, G., Hess, H., Tinnefeld, P., et al. (2015) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/48/44/443001 · Cited by 325
Self-citationSTED Nanoscopy Reveals the Ubiquity of Subcortical Cytoskeleton Periodicity in Living Neurons
D’Este, E., Kamin, D., Göttfert, F., El-Hady, A., & Hell, S. W. (2015) · Cell Reports · doi:10.1016/j.celrep.2015.02.007 · Cited by 316
Self-citationSchmidt, R., Weihs, T., Wurm, C. A., Jansen, I., Rehman, J., Sahl, S. J., & Hell, S. W. (2021) · Nature Communications · doi:10.1038/s41467-021-21652-z · Cited by 306
Self-citationPleiner, T., Bates, M., Trakhanov, S., Lee, C.-T., Schliep, J. E., Chug, H., Böhning, M., Stark, H., Urlaub, H., & Görlich, D. (2015) · eLife · doi:10.7554/elife.11349 · Cited by 242
“…with site-specifically labeled nanobodies Due to a diameter well below the diffraction limit, NPCs have been studied by super-resolution microscopy using either indirect immunofluorescence (Löschberger et al., 2012; Göttfert et al., 2013) or the anti-GFP nanobody (Szymborska et al., 2013).”
BackgroundToxic PR n poly-dipeptides encoded by the C9orf72 repeat expansion block nuclear import and export
Shi, K. Y., Mori, E., Nizami, Z. F., Lin, Y., Kato, M., Xiang, S., Wu, L. C., Ding, M., Yu, Y., Gall, J. G., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1620293114 · Cited by 242
Active zone scaffolds differentially accumulate Unc13 isoforms to tune Ca2+ channel–vesicle coupling
Böhme, M. A., Beis, C., Reddy-Alla, S., Reynolds, E., Mampell, M. M., Grasskamp, A. T., Lützkendorf, J., Bergeron, D. D., Driller, J. H., Babikir, H., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4364 · Cited by 219
Self-citationXu, Y., Xu, R., Wang, Z., Zhou, Y., Shen, Q., Ji, W., Dang, D., Meng, L., & Tang, B. Z. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00676a · Cited by 181
The cell biologist's guide to super-resolution microscopy
Jacquemet, G., Carisey, A. F., Hamidi, H., Henriques, R., & Leterrier, C. (2020) · Journal of Cell Science · doi:10.1242/jcs.240713 · Cited by 171
Qudi: A modular python suite for experiment control and data processing
Binder, J. M., Stark, A., Tomek, N., Scheuer, J., Frank, F., Jahnke, K. D., Müller, C., Schmitt, S., Metsch, M. H., Unden, T., et al. (2017) · SoftwareX · doi:10.1016/j.softx.2017.02.001 · Cited by 168
“As evidenced by the 2014 Nobel Prize in Chemistry, these techniques have expanded beyond the context of physics and now this kind of microscope is pushing advances in biology [6, 7, 8] and nanotechnology [9, 10].”
Adaptive-illumination STED nanoscopy
Heine, J., Reuss, M., Harke, B., D’Este, E., Sahl, S. J., & Hell, S. W. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1708304114 · Cited by 165
“DyMIN can readily be applied to multichannel recordings using dyes at different wavelengths (6).”
BackgroundSelf-citationHydrophobic mismatch sorts SNARE proteins into distinct membrane domains
Milovanovic, D., Honigmann, A., Koike, S., Göttfert, F., Pähler, G., Junius, M., Müllar, S., Diederichsen, U., Janshoff, A., Grubmüller, H., et al. (2015) · Nature Communications · doi:10.1038/ncomms6984 · Cited by 162
Self-citationSeeing beyond the limit: A guide to choosing the right super-resolution microscopy technique
Valli, J., Garcia-Burgos, A., Rooney, L. M., Vale de Melo e Oliveira, B., Duncan, R. R., & Rickman, C. (2021) · Journal of Biological Chemistry · doi:10.1016/j.jbc.2021.100791 · Cited by 159
Metadata
- Authors
- Göttfert, F., Wurm, C. A., Mueller, V., Berning, S., Cordes, V. C., Honigmann, A., & Hell, S. W.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 105
- Issue
- 1
- Pages
- L01-L03
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2146115281
- Cited by
- 298
- References
- 15
- FWCI
- 20.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.