CoChat

Rebound symptoms following battery depletion in the NIH OCD DBS cohort: Clinical and reimbursement issues

Open access
Vora, A.K., Ward, H., Foote, K.D., Goodman, W.K., Okun, M.S. · 2012 · Brain Stimulation
Cited by 48

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

OBJECTIVE Deep brain stimulation (DBS) is a promising treatment for medication refractory obsessive compulsive disorder (OCD); however, there may be neuropsychiatric symptoms from unintended battery failure. BACKGROUND Previous studies indicated rebound symptoms from impulse generator (IPG) failure in Parkinson's disease, dystonia, and essential tremor. Unique to OCD is that battery failure may precipitate neuropsychiatric symptoms rather than motor symptoms. METHODS Six patients with medication refractory OCD received implants as part of the previously reported National Institutional Health (NIH) DBS cohort. All available clinical data and adverse event data was reviewed. RESULTS The average age of cohort was 42.2 years (30-59 years), and the average baseline Y-BOCS score was 33.8 (31-38). All six subjects were observed to have increased OCD symptomatology during IPG failure; however, Y-BOCS scores remained less than pretreatment range, in five subjects. One of the subjects had a Y-BOCS score greater than pretreatment during the period of IPG failure. In addition, Y-BOCS scores improved back to baseline after IPG replacement in five subjects. Other symptoms potentially related to battery failure included: suicidality (n = 1), mood disturbance (n = 2), panic attacks (n = 1), fatigue (n = 2), and a restless sensation in the arms and legs (n = 1). A small number of subjects reported no side effects associated with IPG failure because of preemptive replacement (n = 2). CONCLUSIONS This is a preliminary case series detailing the side effects resulting from IPG failure during OCD DBS. Preemptive battery replacement was an effective strategy for avoiding these issues, and timeliness in insurance reimbursement may be considered in the future. Additionally the use of rechargeable batteries may also help this issue. CLINICAL TRIAL REGISTRATION NUMBER NCT00057603.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.brs.2011.10.004

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 48

Metadata

Authors
Vora, A. K., Ward, H., Foote, K. D., Goodman, W. K., & Okun, M. S.
Venue
Brain Stimulation
Publisher
Elsevier BV
Published
2012-10
Volume
5
Issue
4
Pages
599-604
ISSN
  • 1876-4754 (ISSN-L)
  • 1935-861X
OpenAlex
W2044582016
Cited by
48
References
1
FWCI
3.64
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Rebound symptoms following battery depletion in the NIH OCD DBS cohort: Clinical and reimbursement issues. https://app.cochat.ai/papers/10.1016/j.brs.2011.10.004
The paper
Vora, A. K., Ward, H., Foote, K. D., Goodman, W. K., & Okun, M. S. (2012). Rebound symptoms following battery depletion in the NIH OCD DBS cohort: Clinical and reimbursement issues. Brain Stimulation. https://doi.org/10.1016/j.brs.2011.10.004

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.