Blood Oxygenation Changes Modulated by Coil Orientation During Prefrontal Transcranial Magnetic Stimulation
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND Prefrontal transcranial magnetic stimulation (TMS) is being investigated as a treatment for several neurological and psychiatric disorders. The direction of the cortical current induced by TMS can be modulated by the coil orientation and this influences the extent of neural depolarization. Although the optimal coil orientation has previously been established for motor cortex, identifying an optimal coil orientation for prefrontal areas is more challenging due to the absence of a motor response. The current study used near infra-red spectroscopy (NIRS) to investigate the impact of coil orientation on TMS induced changes in prefrontal blood oxygenation (HbO). It was hypothesized that a greater change in HbO would be observed when current was induced in a posterior to anterior direction. METHODS Single pulse and trains of 1 Hz repetitive TMS (rTMS) were administered to the left prefrontal cortex while simultaneously recording HbO response bilaterally. The effect of coil orientation was examined at 45°, 135°, and 225° counterclockwise from midline. RESULTS Greatest changes in HbO were observed at a 45° orientation when both single and rTMS were applied, and only minor changes were observed at 135° and 225°. Application of short trains of rTMS at 45° resulted in transient increases in HbO that were significantly greater in magnitude than when the coil orientation was reversed. CONCLUSIONS The utility of NIRS for examining the TMS evoked physiological response at non-motor areas is highlighted in this study. Prefrontal HbO response evoked by TMS is sensitive to the direction of induced cortical current and it appears that the de facto 45° angle utilized in most clinical studies may prove to be optimal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rossi, S., Hallett, M., Rossini, P. M., & Pascual-Leone, A. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.08.016 · Cited by 5,367 · cited 1×
“All subjects were neurologically healthy and were safety screened using the criteria proposed by Rossi and colleagues [24].”
MethodO’Reardon, J. P., Solvason, H. B., Janicak, P. G., Sampson, S., Isenberg, K. E., Nahas, Z., McDonald, W. M., Avery, D., Fitzgerald, P. B., Loo, C., et al. (2007) · Biological Psychiatry · doi:10.1016/j.biopsych.2007.01.018 · Cited by 1,910
Self-citationIs there a future for therapeutic use of transcranial magnetic stimulation?
Ridding, M. C., & Rothwell, J. C. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2169 · Cited by 687
Transcranial Magnetic Stimulation: Applications in Neuropsychiatry
George, M. S., Lisanby, S. H., & Sackeim, H. A. (1999) · Archives of General Psychiatry · doi:10.1001/archpsyc.56.4.300 · Cited by 496
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277 · cited 1×
“The Differential Pathlength Factor (DPF) and change in absorption were calculated from the AC and phase [27] and changes in HbO were then calculated with the extinction coefficients corresponding to the selected wavelengths [28].”
Method
Cited by
Fitzgerald, P. B. (2021) · Brain Stimulation · doi:10.1016/j.brs.2021.04.018 · Cited by 126
Self-citationChung, S. W., Lewis, B. P., Rogasch, N. C., Saeki, T., Thomson, R. H., Hoy, K. E., Bailey, N. W., & Fitzgerald, P. B. (2017) · Clinical Neurophysiology · doi:10.1016/j.clinph.2017.04.005 · Cited by 133
Self-citationDijkstra, E., van Dijk, H., Vila-Rodriguez, F., Zwienenberg, L., Rouwhorst, R., Coetzee, J. P., Blumberger, D. M., Downar, J., Williams, N., Sack, A. T., et al. (2023) · Biological Psychiatry Global Open Science · doi:10.1016/j.bpsgos.2023.01.003 · Cited by 31
“The rTMS coil was positioned over the Beam and 5CM location at an angle of 45 relative to the parasagittal plane (the coil handle pointing posteriorly), which seems to be the optimal angle to stimulate frontal areas (20) and which is used in most depression trials (21).”
BackgroundMeek, B. P., Hill, S., & Modirrousta, M. (2021) · Brain Injury · doi:10.1080/02699052.2020.1857837 · Cited by 16
“For example, extended LF stimulation over the DLPFC produces increases in HbO bilaterally (100), and frontal HbO increases”
Background
Metadata
- Authors
- Thomson, R. H., Cleve, T. J., Bailey, N. W., Rogasch, N. C., Maller, J. J., Daskalakis, Z. J., & Fitzgerald, P. B.
- Venue
- Brain Stimulation
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 6
- Issue
- 4
- Pages
- 576-581
- ISSN
- 1876-4754 (ISSN-L)
- 1935-861X
- OpenAlex
- W2158610384
- Cited by
- 49
- References
- 5
- FWCI
- 0.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Blood Oxygenation Changes Modulated by Coil Orientation During Prefrontal Transcranial Magnetic Stimulation. https://app.cochat.ai/papers/10.1016/j.brs.2012.12.001
- The paper
- Thomson, R. H., Cleve, T. J., Bailey, N. W., Rogasch, N. C., Maller, J. J., Daskalakis, Z. J., & Fitzgerald, P. B. (2013). Blood Oxygenation Changes Modulated by Coil Orientation During Prefrontal Transcranial Magnetic Stimulation. Brain Stimulation. https://doi.org/10.1016/j.brs.2012.12.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.