Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 173

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Automatic epileptic EEG detection using convolutional neural network with improvements in time-domain

Wei, Zuochen, Zou, Junzhong, Zhang, Jian, Xu, Jianqiang · 2019 · Biomedical Signal Processing and Control

Abstract

Abstract Epilepsy is a neurological disorder, and clinicians usually diagnose epilepsy by interpreting electroencephalogram (EEG) manually. This paper proposes a novel automatic epileptic EEG detection method based on convolutional neural network (CNN) with two innovative improvements and treats this task as a big data classification issue. Due to that CNN could extract and learn features automatically, the multi-channels time-series EEG recordings extracted by a sliding window are fed into the CNN model. Firstly, a 12-layers CNN is designed as the baseline epileptic EEG classification model. Afterward, the merger of the increasing and decreasing sequences (MIDS) is introduced to highlight the characteristic of waveforms. Then, a data augmentation method, Wasserstein Generative Adversarial Nets (WGANs), increases the sample diversity as well as EEG information. In this experiment, the recordings are from CHB-MIT Scalp EEG database, and the patient-cross performance with the train set from other patients and test set from the withheld patient is evaluated. The epileptic EEG classification results show that the original CNN achieves 70.68% sensitivity and 92.30% specificity, while CNN with MIDS and data augmentation yield 74.08% sensitivity, 92.46% specificity and 72.11% sensitivity, 95.89% specificity respectively. These two novel improvements both increased automatic epileptic EEG classification performance. Furthermore, in seizure onset detection, 90.57% seizure events are detected with the mean latency 4.68s using probability smoothing. The proposed method could lighten the EEG interpretation workload of clinicians effectively, and has great significance in auxiliary diagnosis of epilepsy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bspc.2019.04.028

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 173

Metadata

Authors
Wei, Z., Zou, J., Zhang, J., & Xu, J.
Venue
Biomedical Signal Processing and Control
Publisher
Elsevier BV
Published
2019-08
Volume
53
Pages
101551
ISSN
1746-8094 (ISSN-L)
OpenAlex
W2946520801
Cited by
173
References
6
FWCI
10.82
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automatic epileptic EEG detection using convolutional neural network with improvements in time-domain. https://app.cochat.ai/papers/10.1016/j.bspc.2019.04.028
The paper
Wei, Z., Zou, J., Zhang, J., & Xu, J. (2019). Automatic epileptic EEG detection using convolutional neural network with improvements in time-domain. Biomedical Signal Processing and Control. https://doi.org/10.1016/j.bspc.2019.04.028

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.