CoChat

MoDTRAP: Improved heart rate tracking and preprocessing of motion-corrupted photoplethysmographic data for personalized healthcare

Roy, Biplab, Gupta, Rajarshi · 2020 · Biomedical Signal Processing and Control
Cited by 30

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Abstract Objective A new joint framework for heart rate (HR) tracking and preprocessing of motion artifact (MA) corrupted photoplethysmogram (PPG) data is presented. Methods Two popular signal decomposition techniques, viz., variational mode decomposition (VMD) to track HR, and ensemble empirical mode decomposition (EEMD) in conjunction with an artificial neural network (NN) model was utilized for preprocessing. The HR frequency was estimated from the signal strengths of VMD decomposed mode functions and tracked with an indigenous algorithm utilizing the fact that the PPG signal normally comprises base HR frequency along with its harmonics. For MA reduction, The HR synchronous signal component was extracted from the appropriate mode functions of VMD decomposition and reconstructed to minimize MA using a template matching technique utilizing an autoencoder and pre-trained multilayer feedforward neural network model. A combination of EEMD followed by a LSTM binary classifier was used to generate and update the reference PPG template beat for the above purpose. Results With 2015 IEEE signal processing cup challenge database, an average absolute error and percent absolute error of 1.02 and 0.86 respectively compared to the ground truth HR were obtained for all 22 subjects. For MA reduction, we used wrist PPG data collected from 30 human subjects (normal and cardiovascular patients), achieving an average root mean squared error (RMSE) of 0.31 and SNR improvement of 21.23 dB. Conclusion Proposed MoDTRAP technique provides noticeable improvements, separately, over existing methods on HR tracking and MA reduction. Significance The proposed technique can be utilized for ambulatory healthcare monitoring.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bspc.2019.101676

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 30

Metadata

Authors
Roy, B., & Gupta, R.
Venue
Biomedical Signal Processing and Control
Publisher
Elsevier BV
Published
2020-02
Volume
56
Pages
101676
ISSN
1746-8094 (ISSN-L)
OpenAlex
W2980632631
Cited by
30
References
3
FWCI
1.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MoDTRAP: Improved heart rate tracking and preprocessing of motion-corrupted photoplethysmographic data for personalized healthcare. https://app.cochat.ai/papers/10.1016/j.bspc.2019.101676
The paper
Roy, B., & Gupta, R. (2020). MoDTRAP: Improved heart rate tracking and preprocessing of motion-corrupted photoplethysmographic data for personalized healthcare. Biomedical Signal Processing and Control. https://doi.org/10.1016/j.bspc.2019.101676

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.