A robust heart rate monitoring scheme using photoplethysmographic signals corrupted by intense motion artifacts

Khan, Emroz, Al Hossain, Forsad, Uddin, Shiekh Zia, Alam, S. Kaisar, Hasan, Md. Kamrul·2016·IEEE Transactions on Biomedical Engineering

Abstract

GOAL: Although photoplethysmographic (PPG) signals can monitor heart rate (HR) quite conveniently in hospital environments, trying to incorporate them during fitness programs poses a great challenge, since in these cases, the signals are heavily corrupted by motion artifacts. METHODS: In this paper, we present a novel signal processing framework which utilizes two channel PPG signals and estimates HR in two stages. The first stage eliminates any chances of a runaway error by resorting to an absolute criterion condition based on ensemble empirical mode decomposition. This stage enables the algorithm to depend very little on the previously estimated HR values and to discard the need of an initial resting phase. The second stage, on the other hand, increases the algorithm's robustness against offtrack errors by using recursive least squares filters complemented with an additional novel technique, namely time-domain extraction. RESULTS: Using this framework, an average absolute error of 1.02 beat per minute (BPM) and standard deviation of 1.79 BPM are recorded for 12 subjects performing a run with peak velocities reaching as high as 15 km/h. CONCLUSION: The performance of this algorithm is found to be better than the other recently reported algorithms in this field such as TROIKA and JOSS. SIGNIFICANCE: This method is expected to greatly facilitate the presently available wearable gadgets in HR computation during various physical activities.

Integrity signals

Registry

Crossref · 10.1109/tbme.2015.2466075

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.

    “As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Khan, E., Al Hossain, F., Uddin, S. Z., Alam, S. K., & Hasan, M. K.
Affiliations
Bangladesh University of Engineering and Technology (BD)
Venue
IEEE Transactions on Biomedical Engineering
Published
2016-03
Volume
63
Issue
3
Pages
550-562
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2288945889
Cited by
153
References
20
Citations by year
2026: 4 · 2025: 5 · 2024: 9 · 2023: 16 · 2022: 14 · 2021: 20 · 2020: 15 · 2019: 29 · 2018: 11 · 2017: 21 · 2016: 8 · 2015: 1
FWCI
6.79
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
heart rate monitoring, photoplethysmography, motion artifacts, ensemble empirical mode decomposition, recursive least squares, wearable sensors, physical activity
MeSH terms
Adolescent, Adult, Algorithms, Female, Heart Rate, Humans, Male, Middle Aged, Signal Processing, Computer-Assisted, Artifacts, Photoplethysmography, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review