A robust heart rate monitoring scheme using photoplethysmographic signals corrupted by intense motion artifacts
Abstract
GOAL: Although photoplethysmographic (PPG) signals can monitor heart rate (HR) quite conveniently in hospital environments, trying to incorporate them during fitness programs poses a great challenge, since in these cases, the signals are heavily corrupted by motion artifacts. METHODS: In this paper, we present a novel signal processing framework which utilizes two channel PPG signals and estimates HR in two stages. The first stage eliminates any chances of a runaway error by resorting to an absolute criterion condition based on ensemble empirical mode decomposition. This stage enables the algorithm to depend very little on the previously estimated HR values and to discard the need of an initial resting phase. The second stage, on the other hand, increases the algorithm's robustness against offtrack errors by using recursive least squares filters complemented with an additional novel technique, namely time-domain extraction. RESULTS: Using this framework, an average absolute error of 1.02 beat per minute (BPM) and standard deviation of 1.79 BPM are recorded for 12 subjects performing a run with peak velocities reaching as high as 15 km/h. CONCLUSION: The performance of this algorithm is found to be better than the other recently reported algorithms in this field such as TROIKA and JOSS. SIGNIFICANCE: This method is expected to greatly facilitate the presently available wearable gadgets in HR computation during various physical activities.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.
“As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [176]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Haykin, S. (1986) · Cited by 12,603 · see citing works
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
Wu, Z., & Huang, N. E. (2008) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,847 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Wittenmark, B. (1993) · Automatica · doi:10.1016/0005-1098(93)90162-m · Cited by 3,067 · see citing works
Zhang, Z., Pi, Z., & Liu, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 759 · see citing works
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400 · see citing works
Zhang, Z. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2406332 · Cited by 388 · see citing works
A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter
Ram, M. R., Madhav, K. V., Krishna, E. H., Komalla, N. R., & Reddy, K. A. (2011) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2011.2175832 · Cited by 345 · see citing works
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328 · see citing works
Sweeney, K. T., McLoone, S., & Ward, T. E. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2225427 · Cited by 299 · see citing works
Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data
Krishnan, R., Natarajan, B., & Warren, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2039568 · Cited by 263 · see citing works
A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors
Yousefi, R., Nourani, M., Ostadabbas, S., & Panahi, I. M. S. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2264358 · Cited by 229 · see citing works
Lee, B., Han, J., Baek, H. J., Shin, J. H., Park, K. S., & Yi, W. J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/003 · Cited by 155 · see citing works
Peng, F., Zhang, Z., Gou, X., Liu, H., & Wang, W. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-50 · Cited by 136 · see citing works
A simple time domain algorithm for the detection of ventricular fibrillation in electrocardiogram
Arafat, M. A., Chowdhury, A. W., & Hasan, M. K. (2009) · Signal Image and Video Processing · doi:10.1007/s11760-009-0136-1 · Cited by 83 · see citing works
Sun, X., Yang, P., Li, Y., Gao, Z., & Zhang, Y. (2012) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2012.6211698 · Cited by 75 · see citing works
Foo, J. Y. A. (2006) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2006.01.001 · Cited by 70 · see citing works
Heuristic algorithm for photoplethysmographic heart rate tracking during maximal exercise test
Silva, S. M. L. (2011) · Journal of Medical and Biological Engineering · doi:10.5405/jmbe.898 · Cited by 41 · see citing works
Undergraduate Students Compete in the IEEE Signal Processing Cup: Part 1 [sp Education]
Lam, K., Sorzano, C. Ó. S., Zhang, Z., & Campisi, P. (2015) · IEEE Signal Processing Magazine · doi:10.1109/msp.2015.2419291 · Cited by 15 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Accurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 295 · see citing works
Biswas, D., Everson, L. R., Liu, M., Panwar, M., Verhoef, B.-E., Patki, S., Kim, C. H., Acharyya, A., Hoof, C. A. V., Konijnenburg, M., et al. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2892297 · Cited by 293 · see citing works
Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simões‐Capela, N., Hoof, C. A. V., & Helleputte, N. V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 263 · see citing works
PP-Net: A Deep Learning Framework for PPG-Based Blood Pressure and Heart Rate Estimation
Panwar, M., Gautam, A., Biswas, D., & Acharyya, A. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2990864 · Cited by 238 · see citing works
Molecular Communication and Nanonetwork for Targeted Drug Delivery: A Survey
Chude-Okonkwo, U. A. K., Malekian, R., Maharaj, B. T., & Vasilakos, A. V. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2017.2705740 · Cited by 211 · see citing works
Mashhadi, M. B., Asadi, E., Eskandari, M., Kiani, S., & Marvasti, F. (2015) · IEEE Signal Processing Letters · doi:10.1109/lsp.2015.2509868 · Cited by 144 · see citing works
Jarchi, D., & Casson, A. J. (2016) · Data · doi:10.3390/data2010001 · Cited by 120 · see citing works
Min, S., An, J., Lee, J. H., Kim, J. H., Joe, D. J., Eom, S. H., Yoo, C. D., Ahn, H., Hwang, J.-Y., Xu, S. H., et al. (2025) · Nature Reviews Cardiology · doi:10.1038/s41569-025-01127-0 · Cited by 132 · see citing works
Scardulla, F., Cosoli, G., Spinsante, S., Poli, A., Iadarola, G., Pernice, R., Busacca, A., Pasta, S., Scalise, L., & D’Acquisto, L. (2023) · Measurement · doi:10.1016/j.measurement.2023.113150 · Cited by 120 · see citing works
Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101 · see citing works
Cosoli, G., Spinsante, S., Scardulla, F., D’Acquisto, L., & Scalise, L. (2021) · Measurement · doi:10.1016/j.measurement.2021.109243 · Cited by 98 · see citing works
Pankaj, Kumar, A., Komaragiri, R., & Kumar, M. (2021) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-021-09597-4 · Cited by 84 · see citing works
Motion artifact cancellation in wearable photoplethysmography using gyroscope
Lee, H., Chung, H., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2879970 · Cited by 79 · see citing works
Particle Filtering and Sensor Fusion for Robust Heart Rate Monitoring Using Wearable Sensors
Nathan, V., & Jafari, R. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2783758 · Cited by 79 · see citing works
Learning Your Heart Actions From Pulse: ECG Waveform Reconstruction From PPG
Zhu, Q., Tian, X., Wong, C.-W., & Wu, M. H. (2021) · IEEE Internet of Things Journal · doi:10.1109/jiot.2021.3097946 · Cited by 80 · see citing works
Measuring Heart Rate During Physical Exercise by Subspace Decomposition and Kalman Smoothing
Galli, A., Narduzzi, C., & Giorgi, G. B. D. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2017.2770818 · Cited by 72 · see citing works
Identification of Atrial Fibrillation by Quantitative Analyses of Fingertip Photoplethysmogram
Tang, S.-C., Huang, P.-W., Hung, C.-S., Shan, S.-M., Lin, Y.-H., Shieh, J., Lai, D., Wu, A.-Y. (., & Jeng, J. (2017) · Scientific Reports · doi:10.1038/srep45644 · Cited by 64 · see citing works
Lee, H., Chung, H., Ko, H., & Lee, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2801385 · Cited by 61 · see citing works
Chung, H., Lee, H., & Lee, J. (2018) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2871177 · Cited by 61 · see citing works
A Robust Fusion Method for Motion Artifacts Reduction in Photoplethysmography Signal
Nabavi, S. K., & Bhadra, S. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3006636 · Cited by 60 · see citing works
Gyroscope vs. accelerometer measurements of motion from wrist PPG during physical exercise
Casson, A. J., Vazquez Galvez, A., & Jarchi, D. (2016) · ICT Express · doi:10.1016/j.icte.2016.11.003 · Cited by 57 · see citing works
Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity
Jarchi, D., & Casson, A. J. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668763 · Cited by 58 · see citing works
Binary CorNET: Accelerator for HR Estimation From Wrist-PPG
Rocha, L. M. G., Biswas, D., Verhoef, B.-E., Bampi, S., Hoof, C. A. V., Konijnenburg, M., Verhelst, M., & Helleputte, N. V. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3001675 · Cited by 57 · see citing works
Physical Workload Tracking Using Human Activity Recognition with Wearable Devices
Manjarrés, J., Narváez, P., Gasser, K., Percybrooks, W., & Pardo, M. (2019) · Sensors · doi:10.3390/s20010039 · Cited by 58 · see citing works
Chang, X., Li, G., Xing, G., Zhu, K., & Tu, L. (2021) · ACM Transactions on Sensor Networks · doi:10.1145/3441626 · Cited by 55 · see citing works
Prabha, A., Yadav, J., Rani, A., & Singh, V. (2022) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2022.103876 · Cited by 56 · see citing works
Chung, H., Ko, H., Lee, H., & Lee, J. (2020) · IEEE Access · doi:10.1109/access.2020.2981956 · Cited by 48 · see citing works
NAS-PPG: PPG-Based Heart Rate Estimation Using Neural Architecture Search
Song, S. B., Nam, J., & Kim, J. H. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3073047 · Cited by 47 · see citing works
Fallet, S., & Vésin, J.-M. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa506e · Cited by 47 · see citing works
Schäck, T., Muma, M., & Zoubir, A. M. (2017) · European Signal Processing Conference (EUSIPCO) · doi:10.23919/eusipco.2017.8081656 · Cited by 46 · see citing works
Heart rate estimation from photoplethysmography signal for wearable health monitoring devices
Arunkumar, K. R., & Bhaskar, M. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.01.021 · Cited by 46 · see citing works
Xu, K., Jiang, X., & Chen, W. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2960370 · Cited by 46 · see citing works
A Review of Methods for Non-Invasive Heart Rate Measurement on Wrist
De Pinho Ferreira, N., Gehin, C., & Massot, B. (2021) · IRBM · doi:10.1016/j.irbm.2020.04.001 · Cited by 49 · see citing works
Ye, Y., He, W., Cheng, Y., Huang, W., & Zhang, Z. (2017) · Sensors · doi:10.3390/s17020385 · Cited by 43 · see citing works
Pankaj, Kumar, A., Komaragiri, R., & Kumar, M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.105081 · Cited by 42 · see citing works
Is Continuous Heart Rate Monitoring of Livestock a Dream or Is It Realistic? A Review
Nie, L., Berckmans, D., Wang, C., & Li, B. (2020) · Sensors · doi:10.3390/s20082291 · Cited by 43 · see citing works
Mental Stress Detection Using a Wearable In-Ear Plethysmography
Barki, H., & Chung, W. (2023) · Biosensors · doi:10.3390/bios13030397 · Cited by 40 · see citing works
Cicone, A., & Wu, H. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00701 · Cited by 40 · see citing works
Heart rate estimation from wrist-type photoplethysmography signals during physical exercise
Arunkumar, K. R., & Bhaskar, M. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101790 · Cited by 40 · see citing works
Wang, M., Li, Z., Zhang, Q., & Wang, G. (2019) · Sensors · doi:10.3390/s19153312 · Cited by 39 · see citing works
A Paper-Based Flexible Tactile Sensor Array for Low-Cost Wearable Human Health Monitoring
Luo, W., Sharma, V., & Young, D. J. (2020) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2020.3011498 · Cited by 39 · see citing works
Marefat, F., Erfani, R., Kilgore, K. L., & Mohseni, P. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3038046 · Cited by 39 · see citing works
Atrial fibrillation episodes detection based on classification of heart rate derived features
Henzel, N., Wróbel, J., & Horoba, K. (2017) · International Conference Mixed Design of Integrated Circuits and Systems · doi:10.23919/mixdes.2017.8005278 · Cited by 38 · see citing works
Xu, K., Jiang, X., Lin, S., Dai, C., & Chen, W. (2020) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2020.2988097 · Cited by 37 · see citing works
Aygun, A., Ghasemzadeh, H. G., & Jafari, R. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2962627 · Cited by 37 · see citing works
Subaşı, A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-817444-9.00002-7 · Cited by 37 · see citing works
PPG Derived Heart Rate Estimation During Intensive Physical Exercise
Motin, M. A., Karmakar, C. K., & Palaniswami, M. S. (2019) · IEEE Access · doi:10.1109/access.2019.2913148 · Cited by 35 · see citing works
Heart rate estimation in PPG signals using Convolutional-Recurrent Regressor
Ismail, S., Siddiqi, I., & Akram, U. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105470 · Cited by 36 · see citing works
Yen, C.-T., Chang, S., & Liao, C.-H. (2022) · IEEE Access · doi:10.1109/access.2022.3195857 · Cited by 37 · see citing works
Robust De-Noising Technique for Accurate Heart Rate Estimation Using Wrist-Type PPG Signals
Arunkumar, K. R., & Bhaskar, M. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2982540 · Cited by 32 · see citing works
An overview of non-contact photoplethysmography
Demirezen, H., & Erdem, Ç. E. (2017) · Signal Processing and Communications Applications Conference (SIU) · doi:10.1109/siu.2017.7960176 · Cited by 31 · see citing works
Sharma, A. K., Tanwar, R. S., Singh, Y., Sharma, A. K., Daudra, S., Singal, G., Gadekallu, T. R., & Pancholi, S. (2022) · Computers & Electrical Engineering · doi:10.1016/j.compeleceng.2022.108057 · Cited by 31 · see citing works
Roy, B., & Gupta, R. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101676 · Cited by 30 · see citing works
Wang, L., Liu, S., Li, G., & Zhu, R. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113325 · Cited by 29 · see citing works
Islam, M. S., Rabbi, M. S.-E., Dobaie, A. M., & Hasan, M. K. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.05.010 · Cited by 28 · see citing works
PPG and Bioimpedance-Based Wearable Applications in Heart Rate Monitoring—A Comprehensive Review
Lapsa, D., Janeliukštis, R., Metshein, M., & Selavo, L. (2024) · Applied Sciences · doi:10.3390/app14177451 · Cited by 30 · see citing works
ASCII-character-encoding based PPG compression for tele-monitoring system
Mukhopadhyay, S. K., Ahmad, M. O., & Swamy, M. N. S. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.021 · Cited by 27 · see citing works
Energy efficient heart rate sensing using a painted electrode ECG wearable
Krachunov, S., Beach, C., Casson, A. J., Pope, J., Fafoutis, X., Piechocki, R. J., & Craddock, I. J. (2017) · Global Internet of Things Summit (GIoTS) · doi:10.1109/giots.2017.8016260 · Cited by 26 · see citing works
Depth-Based Whole Body Photoplethysmography in Remote Pulmonary Function Testing
Soleimani, V., Mirmehdi, M., Damen, D., Camplani, M., Hannuna, S., Sharp, C., & Dodd, J. W. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2778157 · Cited by 26 · see citing works
Uncertainties in the Analysis of Heart Rate Variability: A Systematic Review
Lü, L., Zhu, T., Morelli, D., Creagh, A. P., Liu, Z., Yang, J., Liu, F., Zhang, Y., & Clifton, D. A. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3271595 · Cited by 28 · see citing works
Paliakaitė, B., Petrėnas, A., Sološenko, A., & Marozas, V. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.102421 · Cited by 24 · see citing works
Visual heart rate estimation and negative feedback control for fitness exercise
Zhao, C., Lin, C., Chen, W., Chen, M.-K., & Wang, J. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101680 · Cited by 24 · see citing works
Integrated Wearable System for Monitoring Heart Rate and Step during Physical Activity
Prawiro, E. A. P. J., Yeh, C.-I., Chou, N., Lee, M.-W., & Lin, Y. (2016) · Mobile Information Systems · doi:10.1155/2016/6850168 · Cited by 24 · see citing works
Robust estimation and tracking of heart rate by PPG signal analysis
Galli, A., Frigo, G., Narduzzi, C., & Giorgi, G. B. D. (2017) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc.2017.7969715 · Cited by 24 · see citing works
Mukhopadhyay, S. K., Ahmad, M. O., & Swamy, M. N. S. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2883396 · Cited by 23 · see citing works
Exploiting Tunable Q-Factor Wavelet Transform Domain Sparsity to Denoise Wrist PPG Signals
Gupta, S., Singh, A. K., Sharma, A., & Tripathy, R. K. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3287248 · Cited by 21 · see citing works
Robust Heart Rate Monitoring for Quasi-Periodic Motions by Wrist-Type PPG Signals
He, W., Ye, Y., Lu, L., Cheng, Y., Li, Y., & Wang, Z. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2019.2912708 · Cited by 21 · see citing works
Arunkumar, K. R., & Bhaskar, M. (2020) · Signal Image and Video Processing · doi:10.1007/s11760-020-01692-6 · Cited by 21 · see citing works
Zheng, X., Dwyer, V. M., Barrett, L. A., Derakhshani, M., & Hu, S. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103303 · Cited by 20 · see citing works
., P., Kumar, A., Kumar, M., & Komaragiri, R. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3322947 · Cited by 20 · see citing works
DeepHeart: Accurate Heart Rate Estimation from PPG Signals Based on Deep Learning
Chang, X., Li, G., Tu, L., Xing, G., & Tian, H. (2019) · IEEE International Conference on Mobile Ad-Hoc and Sensor Systems (MASS) · doi:10.1109/mass.2019.00051 · Cited by 18 · see citing works
Hu, Q., Li, M., Jiang, L., & Liu, M. (2024) · Technology and Health Care · doi:10.3233/thc-231996 · Cited by 17 · see citing works
Periyasamy, V., Pramanik, M., & Ghosh, P. (2017) · Journal of the Indian Institute of Science · doi:10.1007/s41745-017-0037-1 · Cited by 17 · see citing works
Wan, C., Chen, D., & Yang, J. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103189 · Cited by 17 · see citing works
Wearable Integrated Online Fusion Learning Filter for Heart PPG Sensing Tracking
Wen, H., Gao, B., Yang, D., Zhang, Y., Huang, L., & Woo, W. L. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3277719 · Cited by 16 · see citing works
Mashhadi, M. B., Farhadi, M., Essalat, M., & Marvasti, F. (2018) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2018.8461520 · Cited by 16 · see citing works
Multi-Mode Particle Filtering Methods for Heart Rate Estimation From Wearable Photoplethysmography
Lee, J., Chung, H., & Lee, H. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2895685 · Cited by 16 · see citing works
Cross-Domain Joint Dictionary Learning for ECG Inference From PPG
Tian, X., Zhu, Q., Li, Y., & Wu, M. H. (2022) · IEEE Internet of Things Journal · doi:10.1109/jiot.2022.3231862 · Cited by 15 · see citing works
Yen, C.-T., Liao, J.-X., & Huang, Y.-K. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3126744 · Cited by 15 · see citing works
A Novel Scheme for Suppression of Human Motion Effects in Non-Contact Heart Rate Detection
Chen, Z., Liu, Y., Sui, C., Zhou, M., & Song, Y. (2023) · IEEE Access · doi:10.1109/access.2023.3302918 · Cited by 14 · see citing works
Lee, H., Chung, H., Ko, H., Parisi, A., Busacca, A., Faes, L., Pernice, R., & Lee, J. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.107126 · Cited by 14 · see citing works
Talukdar, M. T. F., Pathan, N. S., Fattah, S. A., Quamruzzaman, M., & Saquib, M. (2022) · IEEE Access · doi:10.1109/access.2022.3168742 · Cited by 13 · see citing works
A novel non-contact heart rate measurement method based on EEMD combined with FastICA
Shi, Y., Qiu, J., Li, P., Han, P., Luo, K., & Liu, D. (2023) · Physiological Measurement · doi:10.1088/1361-6579/accefd · Cited by 13 · see citing works
Chung, H., Lee, H., & Lee, J. (2019) · PLoS ONE · doi:10.1371/journal.pone.0215014 · Cited by 13 · see citing works
Zhang, Q., Xie, Q., Wang, M., & Wang, G. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512878 · Cited by 13 · see citing works
Wan, C., Chen, D., Yang, J., & Huang, M. H. (2020) · IEICE Transactions on Information and Systems · doi:10.1587/transinf.2019edp7156 · Cited by 13 · see citing works
Song, J., Li, D., Ma, X., Teng, G., & Wei, J. (2017) · Sensors · doi:10.3390/s17112450 · Cited by 12 · see citing works
Guo, J., Chen, X., Zhao, J., Zhang, X., & Chen, X. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3165071 · Cited by 12 · see citing works
Classification of breast lesions using quantitative ultrasound biomarkers
Nizam, N. I., Ara, S., & Hasan, M. K. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101786 · Cited by 12 · see citing works
Yao, C., Lu, Z., Liu, L., Pan, Y., Qin, W., Ma, S., Sheng, Y., Hong, Z., & Xu, J. (2024) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2024.3503281 · Cited by 11 · see citing works
Cooperative PPG/ECG Wearable System for Atrial Fibrillation Diagnosis
Lee, Y., Lee, S., Kim, S. K., Yon, D. K., Nam, Y., & Lee, J. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3526245 · Cited by 10 · see citing works
Arunkumar, K. R., Srivathsa, R., & Bhaskar, M. (2018) · IEEE Region 10 Conference (TENCON) · doi:10.1109/tencon.2018.8650495 · Cited by 10 · see citing works
PPG-based heart rate estimation using Wiener filter, phase vocoder and Viterbi decoding
Temko, A. (2017) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2017.7952309 · Cited by 9 · see citing works
Heart Rate Estimation from Wrist PPG Signal During Intense Physical Exercise
Hasan, K., Chowdhury, M. H., Pathan, N. S., & Hossain, Q. D. (2023) · SN Computer Science · doi:10.1007/s42979-023-02173-6 · Cited by 9 · see citing works
Mashhadi, M. B., Essalat, M., Ahmadi, M., & Marvasti, F. (2016) · National and International Iranian Conference on Biomedical Engineering (ICBME) · doi:10.1109/icbme.2016.7890946 · Cited by 9 · see citing works
BioTranslator: Inferring R-Peaks from Ambulatory Wrist-Worn PPG Signal
Everson, L. R., Biswas, D., Verhoef, B.-E., Kim, C. H., Hoof, C. A. V., Konijnenburg, M., & Helleputte, N. V. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856450 · Cited by 9 · see citing works
Tiwari, A., Gray, G., Bondi, P., Mahnam, A., & Falk, T. H. (2023) · Sensors · doi:10.3390/s23125606 · Cited by 9 · see citing works
Minimally invasive muscle-based recording of photoplethysmogram toward chronic implantation
Marefat, F., Erfani, R., Kilgore, K. L., & Mohseni, P. (2016) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2016.7833813 · Cited by 9 · see citing works
Blood Pressure and Heart Rate Measurements Using Photoplethysmography with Modified LRCN
Mostafa, S. M., Idris, S. A., & Kaur, M. (2021) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2022.022679 · Cited by 9 · see citing works
- Authors
- Khan, E., Al Hossain, F., Uddin, S. Z., Alam, S. K., & Hasan, M. K.
- Affiliations
- Bangladesh University of Engineering and Technology (BD)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2016-03
- Volume
- 63
- Issue
- 3
- Pages
- 550-562
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2288945889
- Cited by
- 153
- References
- 20
- Citations by year
- 2026: 4 · 2025: 5 · 2024: 9 · 2023: 16 · 2022: 14 · 2021: 20 · 2020: 15 · 2019: 29 · 2018: 11 · 2017: 21 · 2016: 8 · 2015: 1
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- heart rate monitoring, photoplethysmography, motion artifacts, ensemble empirical mode decomposition, recursive least squares, wearable sensors, physical activity
- MeSH terms
- Adolescent, Adult, Algorithms, Female, Heart Rate, Humans, Male, Middle Aged, Signal Processing, Computer-Assisted, Artifacts, Photoplethysmography, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review