Photoplethysmography-based heart rate monitoring in physical activities via joint sparse spectrum reconstruction
Open accessAbstract
GOAL: A new method for heart rate monitoring using photoplethysmography (PPG) during physical activities is proposed. METHODS: It jointly estimates the spectra of PPG signals and simultaneous acceleration signals, utilizing the multiple measurement vector model in sparse signal recovery. Due to a common sparsity constraint on spectral coefficients, the method can easily identify and remove the spectral peaks of motion artifact (MA) in the PPG spectra. Thus, it does not need any extra signal processing modular to remove MA as in some other algorithms. Furthermore, seeking spectral peaks associated with heart rate is simplified. RESULTS: Experimental results on 12 PPG datasets sampled at 25 Hz and recorded during subjects' fast running showed that it had high performance. The average absolute estimation error was 1.28 beat/min and the standard deviation was 2.61 beat/min. CONCLUSION AND SIGNIFICANCE: These results show that the method has great potential to be used for PPG-based heart rate monitoring in wearable devices for fitness tracking and health monitoring.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.
“As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [178]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Suppression of acoustic noise in speech using spectral subtraction
Boll, S. (1979) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1979.1163209 · Cited by 4,678 · see citing works
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967 · see citing works
Sparse solutions to linear inverse problems with multiple measurement vectors
Cotter, S. F., Rao, B. D., Engan, K., & Kreutz-Delgado, K. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.849172 · Cited by 1,394 · see citing works
Eilers, P. H. C. (2003) · Analytical Chemistry · doi:10.1021/ac034173t · Cited by 1,347 · see citing works
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · cited 1× · see citing works
“W ITH the emerging of smart watches and smart wristbands for healthcare and fitness, heart rate (HR) monitoring using photoplethysmography (PPG) [1], [2] recorded from wearers’ wrists becomes a new research topic both in industry and academia.”
BackgroundSparse Signal Recovery With Temporally Correlated Source Vectors Using Sparse Bayesian Learning
Zhang, Z., & Rao, B. D. (2011) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2011.2159773 · Cited by 871 · see citing works
Self-citationZhang, Z., Pi, Z., & Liu, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 759 · see citing works
Self-citationGil, E., Orini, M., Bailón, R., Vergara, J. M., Mainardi, L., & Laguna, P. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/9/015 · Cited by 461 · see citing works
Duarte, M. F., & Baraniuk, R. G. (2012) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2012.08.003 · Cited by 442 · see citing works
Motion Artifact Reduction in Photoplethysmography Using Independent Component Analysis
Kim, B., & Yoo, S. K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.869784 · Cited by 400 · see citing works
Average Case Analysis of Multichannel Sparse Recovery Using Convex Relaxation
Eldar, Y. C., & Rauhut, H. (2010) · IEEE Transactions on Information Theory · doi:10.1109/tit.2009.2034789 · Cited by 358 · see citing works
A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors
Yousefi, R., Nourani, M., Ostadabbas, S., & Panahi, I. M. S. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2264358 · Cited by 229 · see citing works
Maeda, Y., Sekine, M., & Tamura, T. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9505-0 · Cited by 203 · see citing works
Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography
Poh, M., Swenson, N. C., & Picard, R. W. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2042607 · Cited by 189 · see citing works
Lee, B., Han, J., Baek, H. J., Shin, J. H., Park, K. S., & Yi, W. J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/003 · Cited by 155 · see citing works
Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running
Fukushima, H., Kawanaka, H., Bhuiyan, M. S., & OGURI, K. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346570 · Cited by 129 · see citing works
Zhang, Z., Jung, T., Makeig, S., Pi, Z., & Rao, B. D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2319334 · Cited by 110 · see citing works
Self-citationSun, X., Yang, P., Li, Y., Gao, Z., & Zhang, Y. (2012) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI ...) · doi:10.1109/bhi.2012.6211698 · Cited by 75 · see citing works
Evaluation of wavelets for reduction of motion artifacts in photoplethysmographic signals
Raghuram, M., Madhav, K. V., Krishna, E. H., & Reddy, K. A. (2010) · International Conference on Information Science, Signal Processing and their Applications (ISSPA) · doi:10.1109/isspa.2010.5605443 · Cited by 73 · see citing works
Support Recovery of Sparse Signals in the Presence of Multiple Measurement Vectors
Jin, Y., & Rao, B. D. (2013) · IEEE Transactions on Information Theory · doi:10.1109/tit.2013.2238605 · Cited by 54 · see citing works
Zhang, Z. (2014) · IEEE Global Conference on Signal and Information Processing · doi:10.1109/globalsip.2014.7032208 · Cited by 50 · see citing works
Self-citationJoint sparsity recovery for spectral compressed sensing
Chi, Y. (2014) · IEEE International Conference on Acoustics Speech and Signal Processing · doi:10.1109/icassp.2014.6854340 · Cited by 32 · see citing works
Scalable and parameterised VLSI architecture for efficient sparse approximation in FPGAs and SoCs
Ren, F., Xu, W., & Markovic, D. M. (2013) · Electronics Letters · doi:10.1049/el.2013.2978 · Cited by 10 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Khan, E., Al Hossain, F., Uddin, S. Z., Alam, S. K., & Hasan, M. K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2466075 · Cited by 153 · see citing works
Motion Artifact Reduction for Wrist-Worn Photoplethysmograph Sensors Based on Different Wavelengths
Zhang, Y., Song, S., Vullings, R., Biswas, D., Simões-Capela, N., van Helleputte, N., van Hoof, C., & Groenendaal, W. (2019) · Sensors · doi:10.3390/s19030673 · Cited by 140 · see citing works
Heart rate tracking in photoplethysmography signals affected by motion artifacts: a review
Ismail, S., Akram, U., & Siddiqi, I. (2021) · EURASIP Journal on Advances in Signal Processing · doi:10.1186/s13634-020-00714-2 · Cited by 101 · see citing works
Ye, Y., Cheng, Y., He, W., Hou, M., & Zhang, Z. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2597265 · Cited by 94 · see citing works
Self-citationMotion artifact cancellation in wearable photoplethysmography using gyroscope
Lee, H., Chung, H., & Lee, J. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2879970 · Cited by 79 · see citing works
Leth, S., Hansen, J., Nielsen, O., & Dinesen, B. (2017) · Sensors · doi:10.3390/s17010211 · Cited by 64 · see citing works
Current Status and Prospects of Health-Related Sensing Technology in Wearable Devices
Cho, J. (2019) · Journal of Healthcare Engineering · doi:10.1155/2019/3924508 · Cited by 33 · see citing works
Glasstetter, M., Böttcher, S., Zabler, N., Epitashvili, N., Dümpelmann, M., Richardson, M. P., & Schulze-Bonhage, A. (2021) · Sensors · doi:10.3390/s21186017 · Cited by 21 · see citing works
A PPG Signal Dataset Collected in Semi-Naturalistic Settings Using Galaxy Watch
Park, S., Zheng, D., & Lee, U. (2025) · Scientific Data · doi:10.1038/s41597-025-05152-z · Cited by 12 · see citing works
- Authors
- Zhang, Z.
- Corresponding author
- Zhang, Zhilin
- ORCID
- Zhang, Zhilin
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-08
- Volume
- 62
- Issue
- 8
- Pages
- 1902-1910
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2151713296
- Cited by
- 388
- References
- 24
- Citations by year
- 2026: 16 · 2025: 28 · 2024: 22 · 2023: 38 · 2022: 32 · 2021: 37 · 2020: 40 · 2019: 52 · 2018: 37 · 2017: 41 · 2016: 36 · 2015: 9
- FWCI
- 20.38
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Samsung Research America–Dallas
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- photoplethysmography, heart rate monitoring, motion artifact removal, wearable devices, fitness tracking, physical activity
- MeSH terms
- Adolescent, Adult, Algorithms, Clothing, Heart Rate, Humans, Male, Monitoring, Physiologic, Pulse, Signal Processing, Computer-Assisted, Photoplethysmography, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review