Cited by 388Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlECG Monitoring and Analysis

Photoplethysmography-based heart rate monitoring in physical activities via joint sparse spectrum reconstruction

Open access
Zhang, Zhilin·2015·IEEE Transactions on Biomedical Engineering

Abstract

GOAL: A new method for heart rate monitoring using photoplethysmography (PPG) during physical activities is proposed. METHODS: It jointly estimates the spectra of PPG signals and simultaneous acceleration signals, utilizing the multiple measurement vector model in sparse signal recovery. Due to a common sparsity constraint on spectral coefficients, the method can easily identify and remove the spectral peaks of motion artifact (MA) in the PPG spectra. Thus, it does not need any extra signal processing modular to remove MA as in some other algorithms. Furthermore, seeking spectral peaks associated with heart rate is simplified. RESULTS: Experimental results on 12 PPG datasets sampled at 25 Hz and recorded during subjects' fast running showed that it had high performance. The average absolute estimation error was 1.28 beat/min and the standard deviation was 2.61 beat/min. CONCLUSION AND SIGNIFICANCE: These results show that the method has great potential to be used for PPG-based heart rate monitoring in wearable devices for fitness tracking and health monitoring.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2015.2406332

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Secondary sensors can be integrated into PPG sensors to detect motion, including accelerometers, gyroscopes, piezoelectric transducers, or another wavelength of light as a motion reference.

    “As implemented by consumer-grade HR monitors, secondary sensors can also be integrated into PPG sensors to detect motion. These include accelerometers [175,176,177,178,179], gyroscopes [179,180], piezoelectric transducers [181], or the utilization of another wavelength of light as a motion reference [182,183].”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhang, Z.
Corresponding author
Zhang, Zhilin
Venue
IEEE Transactions on Biomedical Engineering
Published
2015-08
Volume
62
Issue
8
Pages
1902-1910
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2151713296
Cited by
388
References
24
Citations by year
2026: 16 · 2025: 28 · 2024: 22 · 2023: 38 · 2022: 32 · 2021: 37 · 2020: 40 · 2019: 52 · 2018: 37 · 2017: 41 · 2016: 36 · 2015: 9
FWCI
20.38
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • arXiv (Cornell University) (submittedVersion)
  • arXiv (Cornell University)
Funders
Samsung Research America–Dallas
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
Keywords
photoplethysmography, heart rate monitoring, motion artifact removal, wearable devices, fitness tracking, physical activity
MeSH terms
Adolescent, Adult, Algorithms, Clothing, Heart Rate, Humans, Male, Monitoring, Physiologic, Pulse, Signal Processing, Computer-Assisted, Photoplethysmography, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review