ECG arrhythmia classification by using a recurrence plot and convolutional neural network
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Abstract Cardiovascular diseases affect approximately 50 million people worldwide; thus, heart disease prevention is one of the most important tasks of any health care system. Despite the high popularity electrocardiography, superior automatic electrocardiography (ECG) signal analysis methods are required. The aim of this research was to design a new deep learning method for effectively classifying arrhythmia by using 2-second segments of 2D recurrence plot images of ECG signals. In the first stage, the noise and ventricular fibrillation (VF) categories were distinguished. In the second stage, the atrial fibrillation (AF), normal, premature AF, and premature VF categories were distinguished. Models were trained and tested using ECG databases publicly available at the website of PhysioNet. The MIT-BIH Arrhythmia Database, Creighton University Ventricular Tachyarrhythmia Database, MIT-BIH Atrial Fibrillation Database, and MIT-BIH Malignant Ventricular Ectopy Database were used to compare six types of arrhythmia. Testing accuracies of up to 95.3 % ± 1.27 % and 98.41 % ± 0.11 % were achieved for arrhythmia detection in the first and second stage, respectively, after five-fold cross-validation. In conclusion, this study provides clinicians with an advanced methodology for detecting and discriminating between different arrhythmia types.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ImageNet classification with deep convolutional neural networks
Krizhevsky, A., Sutskever, I., & Hinton, G. E. (2017) · Communications of the ACM · doi:10.1145/3065386 · Cited by 112,155
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
The impact of the MIT-BIH Arrhythmia Database
Moody, G. B., & Mark, R. G. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.932724 · Cited by 4,812
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., Fox, C. S., et al. (2013) · Circulation · doi:10.1161/cir.0b013e318282ab8f · Cited by 1,294
Excessive Supraventricular Ectopic Activity and Increased Risk of Atrial Fibrillation and Stroke
Binici, Z., Intzilakis, T., Nielsen, O. W., Køber, L., & Sajadieh, A. (2010) · Circulation · doi:10.1161/circulationaha.109.874982 · Cited by 379 · cited 1×
“We used 2-second ECG segments throughout the classification because these segments display some of the features of the arrhythmia types that can be identified in ECGs [65].”
MethodReview of epidemiology and management of atrial fibrillation in developing countries
Nguyen, T. N., Hilmer, S. N., & Cumming, R. G. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2013.01.184 · Cited by 139 · cited 1×
“It can affect people of any age but is more common in the elderly population and rare in the younger generation [14].”
Background
Cited by
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- Mathunjwa, B. M., Lin, Y.-T., Lin, C.-H., Abbod, M. F., & Shieh, J.-S.
- Venue
- Biomedical Signal Processing and Control
- Publisher
- Elsevier BV
- Published
- 2021-02
- Volume
- 64
- Pages
- 102262
- ISSN
- 1746-8094 (ISSN-L)
- OpenAlex
- W3093699748
- Cited by
- 209
- References
- 6
- FWCI
- 14.80
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.