The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Natural ventilation for reducing airborne infection in hospitals
Open accessAbstract
High ventilation rate is shown to be effective for reducing cross-infection risk of airborne diseases in hospitals and isolation rooms. Natural ventilation can deliver much higher ventilation rate than mechanical ventilation in an energy-efficient manner. This paper reports a field measurement of naturally ventilated hospital wards in Hong Kong and presents a possibility of using natural ventilation for infection control in hospital wards. Our measurements showed that natural ventilation could achieve high ventilation rates especially when both the windows and the doors were open in a ward. The highest ventilation rate recorded in our study was 69.0 ACH. The airflow pattern and the airflow direction were found to be unstable in some measurements with large openings. Mechanical fans were installed in a ward window to create a negative pressure difference. Measurements showed that the negative pressure difference was negligible with large openings but the overall airflow was controlled in the expected direction. When all the openings were closed and the exhaust fans were turned on, a reasonable negative pressure was created although the air temperature was uncontrolled. The high ventilation rate provided by natural ventilation can reduce cross-infection of airborne diseases, and thus it is recommended for consideration of use in appropriate hospital wards for infection control. Our results also demonstrated a possibility of converting an existing ward using natural ventilation to a temporary isolation room through installing mechanical exhaust fans.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Natural Ventilation for the Prevention of Airborne Contagion
Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., et al. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040068 · Cited by 420
Cited by
Architectural design influences the diversity and structure of the built environment microbiome
Kembel, S. W., Jones, E., Kline, J., Northcutt, D., Stenson, J., Womack, A. M., Bohannan, B. J. M., Brown, G. Z., & Green, J. L. (2012) · The ISME Journal · doi:10.1038/ismej.2011.211 · Cited by 527
Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings
Qian, H., & Zheng, X. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.01.24 · Cited by 249
Self-citation
Metadata
- Authors
- Qian, H., Li, Y., Seto, W. H., Ching, P., Ching, W. H., & Sun, H. Q.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 45
- Issue
- 3
- Pages
- 559-565
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2052931835
- Cited by
- 170
- References
- 1
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Natural ventilation for reducing airborne infection in hospitals. https://app.cochat.ai/papers/10.1016/j.buildenv.2009.07.011
- The paper
- Qian, H., Li, Y., Seto, W. H., Ching, P., Ching, W. H., & Sun, H. Q. (2010). Natural ventilation for reducing airborne infection in hospitals. Building and Environment. https://doi.org/10.1016/j.buildenv.2009.07.011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.