Cited by 249Infection Control and VentilationIndoor Air Quality and Microbial ExposureInfection Control in Healthcare

Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings

Open access
Qian, Hua, Zheng, Xiaohong·2018·Journal of Thoracic Disease

Abstract

The emergence of respiratory diseases, i.e., severe acute respiratory syndrome (SARS) epidemic in 2003, H1N1 influenza epidemic in 2011 and Middle East respiratory syndrome (MERS) outbreak, reiterated the significance of ventilation in buildings. The role of ventilation in removing exhaled airborne bio-aerosols and preventing cross infections has been multidisciplinary extensively studied after the SARS outbreak in 2003. The characteristics of droplet-borne, short-range airborne and long-range airborne transmission of infectious diseases were identified. Increasing ventilation rate can effectively reduce the risk of long-range airborne transmission, while it may be of little useful in preventing the droplet-borne transmission. To maintain the airflow direction from clean cubicles to dirty cubicles is an effective way to prevent the cross infection between cubicles, which is widely used in hospital isolation rooms. Field measurements showed that wrong air flow direction was due to poor construction quality or maintenance. The impacts of different airflow patterns on removing large droplets and fine droplet nuclei were discussed. Some new concepts in general ventilation systems and local personalized equipment were also introduced. This review updates current knowledge of the airborne transmission of pathogens and the improvement of ventilation efficiency concerning the infection prevention.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.21037/jtd.2018.01.24

Cites

75 of 75 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 7

  1. Langmuir AD. Epidemiology of airborne infection. Bacteriol Rev 1961;25:173-81.
  2. Wells WF. On air-borne infection study II. droplets and droplet nuclei. Am J Hyg 1934; 20:611-18.
  3. ASHRAE. HVAC design manual for hospitals and clinics. 2nd Edition. Atlanta: American Society of Heating Refrigerating and Air-Conditioning Engineers Inc., 2013.
  4. ASHRAE. 1999 HVAC applications handbook. Chapter 7: Health care facilities. .Atlanta, Ga.: American Society J Thorac Dis 2018;10(Suppl 19):S2295-S2304 jtd.amegroups.com Qian and Zheng. Ventilation control of airborne infection of Heating Refrigerating and Air-Conditioning Engineers Inc., 1999.
  5. Pfost JF. A re-evaluation of laminar air flow in hospital operating rooms. ASHRAE Trans 1981;87:729-39.
  6. Yang J, Sekhar C, Cheong KW, et al. CFD study and evaluation of different personalized exhaust devices. HVAC&R Res 2013;19:934-46.
  7. Zheng XH, Qian H, Liu L. Numerical study on a new personalized ventilation system application in cross infection prevention. Journal of Central South University (Science and Technology) 2011;42:3905-11.

Cited by

Sorted by citations

Authors
Qian, H., & Zheng, X.
Affiliations
Southeast University (CN)
Corresponding author
Qian, Hua
Venue
Journal of Thoracic Disease
Published
2018-07
Volume
10
Issue
S9
Pages
S2295-S2304
ISSN
  • 2072-1439 (ISSN-L)
  • 2077-6624
OpenAlex
W2787537960
Cited by
249
References
75
Citations by year
2026: 17 · 2025: 26 · 2024: 23 · 2023: 35 · 2022: 51 · 2021: 44 · 2020: 46 · 2019: 4 · 2018: 2
FWCI
4.29
Type
journal article
Language
en
Open access
Licence
cc-by-nc-nd
Locations
  • Journal of Thoracic Disease (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Natural Science Foundation of China (51378103)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Health Sciences › Medicine › Infectious Diseases › Infection Control in Healthcare
Keywords
ventilation control, airborne transmission, respiratory infections, airflow direction, cross-infection prevention, hospital isolation rooms, ventilation rate, droplet nuclei, SARS, influenza, MERS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review