The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Thermal comfort standards, measured internal temperatures and thermal resilience to climate change of free-running buildings: A case-study of hospital wards
Open accessAbstract
In view of the warming climate, there is increasing concern about the likelihood of overheating inside UK buildings that are not mechanically cooled. A number of studies are examining this matter, of which the DeDeRHECC project is one. The recent availability of the UKCP09 future climate data projections has acted as a stimulus to such work. This paper illustrates how field measurement, thermal modelling and the generation of current and future typical and extreme weather years, can be used to provide a picture of the resilience of buildings to climate change. The unified framework for assessing both measurements and current and future predictions that is offered by the BSEN15251 thermal comfort standard is a crucial component. The paper focuses on internal temperatures during the day and at night in wards within the tower building at Addenbrooke’s hospital, which has a hybrid ventilation strategy. The maintenance of thermal comfort in such spaces is critically important and installing air-conditioning in response to climate change is expensive and potentially energy intensive. Fans appear to be a simple retrofit measure that may substantially improve the wards’ resilience to climate change even in extreme years. Whilst healthcare provides the back cloth, the methodology developed has a much wider utility for assessing thermal comfort in buildings in the current and future climate of the UK.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lomas, K. J., & Ji, Y. (2009) · Energy and Buildings · doi:10.1016/j.enbuild.2009.01.001 · Cited by 127 · cited 4×
“This paper is thus complementary to [10] that examined the future performance of refurbishment measures in passively ventilated ward spaces using the same comfort criteria.”
BackgroundMethodInfluentialSelf-citation
Cited by
Humidity: a review and primer on atmospheric moisture and human health
Davis, R. E., McGregor, G. R., & Enfield, K. B. (2016) · Environmental Research · doi:10.1016/j.envres.2015.10.014 · Cited by 472
Slater, L. J., Anderson, B., Buechel, M., Dadson, S., Han, S., Harrigan, S., Kelder, T., Kowal, K., Lees, T., Matthews, T., et al. (2021) · Hydrology and Earth System Sciences · doi:10.5194/hess-25-3897-2021 · Cited by 357
A review into thermal comfort in buildings
Taleghani, M., Tenpierik, M., Kurvers, S., & van den Dobbelsteen, A. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.05.050 · Cited by 357
The implications of a changing climate for buildings
de Wilde, P., & Coley, D. (2012) · Building and Environment · doi:10.1016/j.buildenv.2012.03.014 · Cited by 328
Attia, S., Levinson, R., Ndongo, E., Holzer, P., Berk Kazanci, O., Homaei, S., Zhang, C., Olesen, B. W., Qi, D., Hamdy, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.110869 · Cited by 208
Metadata
- Authors
- Lomas, K. J., & Giridharan, R.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2012-09
- Volume
- 55
- Pages
- 57-72
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2134306912
- Cited by
- 165
- References
- 1
- FWCI
- 17.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermal comfort standards, measured internal temperatures and thermal resilience to climate change of free-running buildings: A case-study of hospital wards. https://app.cochat.ai/papers/10.1016/j.buildenv.2011.12.006
- The paper
- Lomas, K. J., & Giridharan, R. (2012). Thermal comfort standards, measured internal temperatures and thermal resilience to climate change of free-running buildings: A case-study of hospital wards. Building and Environment. https://doi.org/10.1016/j.buildenv.2011.12.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.