HVAC filtration for controlling infectious airborne disease transmission in indoor environments: Predicting risk reductions and operational costs
Open accessAbstract
This work describes and applies a methodology for estimating the impact of recirculating heating, ventilating, and air-conditioning (HVAC) particle filters on the control of size-resolved infectious aerosols in indoor environments using a modified version of the Wells-Riley model for predicting risks of infectious disease transmission. Estimates of risk reductions and associated operational costs of both HVAC filtration and equivalent outdoor air ventilation are modeled and compared using a case study of airborne transmission of influenza in a hypothetical office space. Overall, recirculating HVAC filtration was predicted to achieve risk reductions at lower costs of operation than equivalent levels of outdoor air ventilation, particularly for MERV 13–16 filters. Medium efficiency filtration products (MERV 7–11) are also inexpensive to operate but appear less effective in reducing infectious disease risks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens
Nicas, M., Nazaroff, W. W., & Hubbard, A. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620590918466 · Cited by 867
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015100 · Cited by 423
Natural Ventilation for the Prevention of Airborne Contagion
Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., et al. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040068 · Cited by 420
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Lindsley, W. G., Pearce, T. A., Hudnall, J. B., Davis, K. A., Davis, S. M., Fisher, M. A., Khakoo, R., Palmer, J. E., Clark, K. E., Celik, I., et al. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.684582 · Cited by 300
Aerosol transmission of rhinovirus colds
Dick, E. C., Jennings, L. C., Mink, K. A., Wartgow, C. D., & Inborn, S. L. (1987) · Journal of Infectious Diseases · doi:10.1093/infdis/156.3.442 · Cited by 280 · cited 1×
“Aerosol transmission has been shown to be a predominant route of transmission for a number of communicable diseases, including rhinovirus [7,13], influenza [14e16], tuberculosis [17], and SARS [18].”
Yang, W., Elankumaran, S., & Marr, L. C. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0686 · Cited by 260 · cited 1×
“[54] Health center, daycare center,”
Cited by
Nazaroff, W. W. (2016) · Indoor Air · doi:10.1111/ina.12174 · Cited by 304
Azuma, K., Yanagi, U., Kagi, N., Kim, H., Ogata, M., & Hayashi, M. (2020) · Environmental Health and Preventive Medicine · doi:10.1186/s12199-020-00904-2 · Cited by 263
Modeling the Impacts of Physical Distancing and Other Exposure Determinants on Aerosol Transmission
Wagner, J., Sparks, T. L., Miller, S., Chen, W., Macher, J. M., & Waldman, J. M. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1963445 · Cited by 21
Metadata
- Authors
- Azimi, P., & Stephens, B.
- Venue
- Building and Environment
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 70
- Pages
- 150-160
- ISSN
- 0360-1323 (ISSN-L)
- OpenAlex
- W2165374220
- Cited by
- 202
- References
- 9
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: HVAC filtration for controlling infectious airborne disease transmission in indoor environments: Predicting risk reductions and operational costs. https://app.cochat.ai/papers/10.1016/j.buildenv.2013.08.025
- The paper
- Azimi, P., & Stephens, B. (2013). HVAC filtration for controlling infectious airborne disease transmission in indoor environments: Predicting risk reductions and operational costs. Building and Environment. https://doi.org/10.1016/j.buildenv.2013.08.025
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.