CoChat

Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs

Open access

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Abstract

Influenza is thought to be communicated from person to person by multiple pathways. However, the relative importance of different routes of influenza transmission is unclear. To better understand the potential for the airborne spread of influenza, we measured the amount and size of aerosol particles containing influenza virus that were produced by coughing. Subjects were recruited from patients presenting at a student health clinic with influenza-like symptoms. Nasopharyngeal swabs were collected from the volunteers and they were asked to cough three times into a spirometer. After each cough, the cough-generated aerosol was collected using a NIOSH two-stage bioaerosol cyclone sampler or an SKC BioSampler. The amount of influenza viral RNA contained in the samplers was analyzed using quantitative real-time reverse-transcription PCR (qPCR) targeting the matrix gene M1. For half of the subjects, viral plaque assays were performed on the nasopharyngeal swabs and cough aerosol samples to determine if viable virus was present. Fifty-eight subjects were tested, of whom 47 were positive for influenza virus by qPCR. Influenza viral RNA was detected in coughs from 38 of these subjects (81%). Thirty-five percent of the influenza RNA was contained in particles>4 µm in aerodynamic diameter, while 23% was in particles 1 to 4 µm and 42% in particles<1 µm. Viable influenza virus was detected in the cough aerosols from 2 of 21 subjects with influenza. These results show that coughing by influenza patients emits aerosol particles containing influenza virus and that much of the viral RNA is contained within particles in the respirable size range. The results support the idea that the airborne route may be a pathway for influenza transmission, especially in the immediate vicinity of an influenza patient. Further research is needed on the viability of airborne influenza viruses and the risk of transmission.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0015100

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Flow chart showing patients and tests performed. The numbers in parentheses are the number of aerosol samples collected using SKC BioSamplers and NIOSH aerosol samplers.
Figure 1 Flow chart showing patients and tests performed. The numbers in parentheses are the number of aerosol samples collected using SKC BioSamplers and NIOSH aerosol samplers.CC0 · PubMed Central
Figure 2 Influenza viral RNA collected from coughs using the NIOSH two-stage aerosol sampler. Influenza viral RNA was detected in the cough aerosols from 32 of 38 influenza-positive patients. This plot shows the number of viral copies per cough detected in aerosol particles collected in sampler tube 1 (>4 µm), tube 2 (1 to 4 µm) and the filter (<1 µm) for each patient, ordered from minimum to maximum. The particles collected in tube 2 and on the filter are respirable (able to reach the alveolar region).
Figure 2 Influenza viral RNA collected from coughs using the NIOSH two-stage aerosol sampler. Influenza viral RNA was detected in the cough aerosols from 32 of 38 influenza-positive patients. This plot shows the number of viral copies per cough detected in aerosol particles collected in sampler tube 1 (>4 µm), tube 2 (1 to 4 µm) and the filter (<1 µm) for each patient, ordered from minimum to maximum. The particles collected in tube 2 and on the filter are respirable (able to reach the alveolar region).CC0 · PubMed Central
Figure 3 Cough aerosol particle collection system. Before each test, the piston spirometer was purged and partially filled with 5 liters of clean dry air. When the patient coughed into the system mouthpiece, the cough flowed through an ultrasonic spirometer which measured the cough volume and flow rate. The cough then flowed through a valve and into the piston spirometer, displacing the piston to the right. When the subject finished coughing, the valve was closed and the aerosol sampler was turned on. The cough aerosol was pulled out of the spirometer and collected by the aerosol sampler. As the aerosol sampler drew air, the piston moved to the left until no air remained in the spirometer.
Figure 3 Cough aerosol particle collection system. Before each test, the piston spirometer was purged and partially filled with 5 liters of clean dry air. When the patient coughed into the system mouthpiece, the cough flowed through an ultrasonic spirometer which measured the cough volume and flow rate. The cough then flowed through a valve and into the piston spirometer, displacing the piston to the right. When the subject finished coughing, the valve was closed and the aerosol sampler was turned on. The cough aerosol was pulled out of the spirometer and collected by the aerosol sampler. As the aerosol sampler drew air, the piston moved to the left until no air remained in the spirometer.CC0 · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 439

Metadata

Authors
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., & Beezhold, D. H.
Affiliations
  • National Institute for Occupational Safety and Health (US)
  • West Virginia University (US)
Corresponding author
Lindsley, William G.
Venue
PLoS ONE
Published
2010-11-30
Volume
5
Issue
11
Pages
e15100
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2040363935
Cited by
423
References
23
Citations by year
2026: 14 · 2025: 22 · 2024: 22 · 2023: 29 · 2022: 32 · 2021: 77 · 2020: 72 · 2019: 12 · 2018: 18 · 2017: 20 · 2016: 15 · 2015: 22 · 2014: 15 · 2013: 21 · 2012: 16
FWCI
14.09
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, public-domain)
  • Europe PMC (PubMed Central) (publishedVersion, public-domain)
  • PubMed Central (publishedVersion, public-domain)
  • PubMed (publishedVersion)
  • The Research Repository @ WVU (West Virginia University) (submittedVersion, public-domain)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
Funders
  • U.S. Environmental Protection Agency
  • Centers for Disease Control and Prevention
  • U.S. Public Health Service (DW7592259701)
  • National Institute for Occupational Safety and Health
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Health Sciences › Medicine › Epidemiology › Influenza Virus Research Studies
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
Keywords
influenza virus, airborne transmission, cough aerosols, aerosol particle size, respiratory droplets, influenza-like illness, viral RNA detection, respiratory infection transmission
MeSH terms
Adolescent, Adult, Aerosols, Air Microbiology, Cough, Female, Humans, Influenza, Human, Male, Orthomyxoviridae, RNA, Viral, Viral Matrix Proteins, Reverse Transcriptase Polymerase Chain Reaction, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs. https://app.cochat.ai/papers/10.1371/journal.pone.0015100
The paper
Lindsley, W. G., Blachere, F. M., Thewlis, R. E., Vishnu, A., Davis, K. A., Cao, G., Palmer, J. E., Clark, K. E., Fisher, M. A., Khakoo, R., & Beezhold, D. H. (2010). Measurements of Airborne Influenza Virus in Aerosol Particles from Human Coughs. PLoS ONE. https://doi.org/10.1371/journal.pone.0015100

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.