The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Synthesis and characterization of hyaluronic acid hydrogels crosslinked using a solvent-free process for potential biomedical applications
Open accessAbstract
Hyaluronic acid (HA) is a natural linear polysaccharide that has been used extensively in the biomedical field as it is a biocompatible, biodegradable, nontoxic and non-immunogenic polymer with high water affinity. Besides, the presence of multiple acid and hydroxyl groups in the HA molecule makes it an ideal candidate for chemical modification. The present paper describes the synthesis and characterization of HA-based hydrogels. For this purpose, aqueous mixtures containing 5% (w/w) of HA and different concentrations of Gantrez S97 (GAN) (1, 3 and 5% w/w) were used to prepare HA-based hydrogels. The mixtures were dried and the hydrogels were obtained after heating the solid material at 80°C for 24h. GAN is the acid form of an methylvinylether and maleic anhydride copolymer and contains multiple acid groups that can form ester bonds when reacting with the multiple hydroxyl groups present in HA chains. The method described here present potential to be applied for the preparation of HA-based biomaterials with a defined form as the crosslinking reaction between HA and the crosslinker takes place in solid phase. Besides, the method can be considered an environmental-friendly process as no organic solvents or potentially toxic substances were used. The esterification reaction was confirmed by infrared spectroscopy and dynamic scanning calorimetry measurements. The loading and release capabilities of the hydrogels were evaluating by using methylene blue (MB) as a model molecule. The hydrogels showed a high affinity for MB showing loadings up to 0.35mg MB per mg of hydrogel. Moreover, the hydrogels were capable of sustaining the MB release over two days. The use of microwave radiation was evaluated to reduce the crosslinking time from 24h to 1h, but this procedure needs to be optimized in future studies. As the crosslinking procedure takes place in solid state, the HA/GAN hydrogels were used to prepare micro-engineered device, microneedle arrays. Finally, the antimicrobial properties of the hydrogels were evaluated. The results showed that the hydrogels presented anti-infective properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plastics Used in Medical Devices
McKeen, L. W. (2014) · Handbook of Polymer Applications in Medicine and Medical Devices · doi:10.1016/b978-0-323-22805-3.00003-7 · Cited by 153
Cited by
The application of hyaluronic acid in bone regeneration
Zhai, P., Peng, X., Li, B., Liu, Y., Sun, H., & Li, X. (2020) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2019.10.169 · Cited by 438
Biodegradable Gelatin Methacryloyl Microneedles for Transdermal Drug Delivery
Luo, Z., Sun, W., Fang, J., Lee, K., Li, S., Gu, Z., Dokmeci, M. R., & Khademhosseini, A. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801054 · Cited by 294
Metadata
- Authors
- Larrañeta, E., Henry, M., Irwin, N. J., Trotter, J., Perminova, A. A., & Donnelly, R. F.
- Venue
- Carbohydrate Polymers
- Publisher
- Elsevier BV
- Published
- 2018-02
- Volume
- 181
- Pages
- 1194-1205
- ISSN
- 0144-8617 (ISSN-L)
- OpenAlex
- W2774700626
- Cited by
- 269
- References
- 1
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synthesis and characterization of hyaluronic acid hydrogels crosslinked using a solvent-free process for potential biomedical applications. https://app.cochat.ai/papers/10.1016/j.carbpol.2017.12.015
- The paper
- Larrañeta, E., Henry, M., Irwin, N. J., Trotter, J., Perminova, A. A., & Donnelly, R. F. (2018). Synthesis and characterization of hyaluronic acid hydrogels crosslinked using a solvent-free process for potential biomedical applications. Carbohydrate Polymers. https://doi.org/10.1016/j.carbpol.2017.12.015
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.