Overview on self-monitoring of blood glucose
Abstract
The self-monitoring of blood glucose (SMBG), traditionally performed by "point-of-care" (POC) devices called portable glucose monitors (PGM) is now considered an integral part of managed care of diabetic patients, especially type 1 diabetics and those on insulin therapy. In patients with type 2 diabetes, SMBG can help to achieve a better glycaemic control, although there is not sufficient evidence to attest that strict monitoring in these patients is associated with an improved outcome. The outcome of several clinical studies, especially in diabetics on insulin therapy, has shown that SMBG plays a key role in preventing complications in the short, medium and long term. According to the current recommendations, SMBG is aimed to achieve and maintain glycaemic control, prevent and identify hypoglycaemia, prevent severe hyperglycaemia, adjust lifestyle changes and establish the need to begin treatment with insulin in gestational diabetes mellitus. However, as clearly highlighted by the American Diabetes Association (ADA) and the National Academy of Clinical Biochemistry (NACB), patients and healthcare personnel should be trained on the appropriate use of the device, as well as on the correct interpretation of data. Moreover, definite analytical targets and appropriate acceptance criteria for performance should be fulfilled before a new device is introduced in the hospital environment, or recommended to the patients. Performance limitations such as hematocrit extremes and analytic…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In tissue, cells are not directly in contact with capillaries, while exchanges between blood and cells are mediated by ISF, allowing passage of electrolytes, nutrients, waste, and hormones.
“In tissue, the cells are not directly in contact with the capillaries, while exchanges between blood and cells are mediated by ISF, thus allowing the passage of electrolytes, nutrients, and waste, as well as hormones 98.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [98]
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559 · see citing works
Meal-Related Structured Self-Monitoring of Blood Glucose
Schwedes, U., Siebolds, M., Mertes, G., & For the SMBG Study Group (2002) · Diabetes Care · doi:10.2337/diacare.25.11.1928 · Cited by 300 · see citing works
Tang, Z., Lee, J. H., Louie, R. F., & Kost, G. J. (2000) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2000-124-1135-eodhlo · Cited by 293 · see citing works
Guerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287 · see citing works
Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284 · see citing works
Peel, E., Douglas, M., & Lawton, J. (2007) · BMJ · doi:10.1136/bmj.39302.444572.de · Cited by 203 · see citing works
Davidson, M. B., Castellanos, M., Kain, D., & Duran, P. (2005) · The American Journal of Medicine · doi:10.1016/j.amjmed.2004.12.006 · Cited by 178 · see citing works
Ellison, J. M., Stegmann, J. M., Colner, S. L., Michael, R. H., Sharma, M. K., Ervin, K. R., & Horwitz, D. L. (2002) · Diabetes Care · doi:10.2337/diacare.25.6.961 · Cited by 133 · see citing works
Kristensen, G. B. B., Nerhus, K., Thue, G., & Sandberg, S. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.031575 · Cited by 68 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Pullano, S. A., Greco, M., Bianco, M. G., Foti, D., Brunetti, A., & Fiorillo, A. S. (2022) · Theranostics · doi:10.7150/thno.64035 · Cited by 210 · see citing works
“In tissue, the cells are not directly in contact with the capillaries, while exchanges between blood and cells are mediated by ISF, thus allowing the passage of electrolytes, nutrients, and waste, as well as hormones [98].”
BackgroundDevice and method for noninvasive glucose assessment
Segman, Y. (. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818763457 · Cited by 55 · see citing works
- Authors
- Montagnana, M., Caputo, M., Giavarina, D., & Lippi, G.
- Affiliations
- University of Verona (IT)
- Ospedale San Bortolo (IT)
- Corresponding author
- Lippi, Giuseppe
- Venue
- Clinica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 402
- Issue
- 1-2
- Pages
- 7-13
- ISSN
- 0009-8981 (ISSN-L)
- OpenAlex
- W1974685557
- Cited by
- 116
- References
- 9
- Citations by year
- 2026: 1 · 2025: 7 · 2024: 5 · 2023: 9 · 2022: 4 · 2021: 9 · 2020: 5 · 2019: 5 · 2018: 7 · 2017: 6 · 2016: 10 · 2015: 5 · 2014: 11 · 2013: 11 · 2012: 6
- FWCI
- 0.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Padua Research Archive (University of Padova) (submittedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
- Keywords
- self-monitoring of blood glucose, point-of-care testing, type 1 diabetes, type 2 diabetes, insulin therapy, glycemic control, hypoglycemia, hyperglycemia, gestational diabetes mellitus, diabetes complications, hematocrit interference, patient training
- MeSH terms
- Acetaminophen, Calibration, Diabetes Mellitus, Hematocrit, Humans, Hyperglycemia, Hypoglycemia, Quality Control, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review