The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Ion Selective Electrodes (ISEs) and interferences—A review
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pharmacological interventions for somatoform disorders in adults
Kleinstäuber, M., Witthöft, M., Steffanowski, A., van Marwijk, H., Hiller, W., & Lambert, M. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010628.pub2 · Cited by 11,335
Cochrane Database of Systematic Reviews
(2008) · Encyclopedia of Public Health · doi:10.1007/978-1-4020-5614-7_436 · Cited by 4,527
Bühlmann, P., Pretsch, E., & Bakker, E. (1998) · Chemical Reviews · doi:10.1021/cr970113+ · Cited by 1,859
Recommendations for Nomenclature of Ion-Selective Electrodes
(1976) · Elsevier eBooks · doi:10.1016/c2013-0-02877-0 · Cited by 391
Mannitol for acute traumatic brain injury
Wakai, A., McCabe, A., Roberts, I., & Schierhout, G. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd001049.pub5 · Cited by 280
pH Effects on Measurements of Ionized Calcium and Ionized Magnesium in Blood
Wang, S., McDonnell, E. H., Sedor, F. A., & Toffaletti, J. G. (2002) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2002-126-0947-peomoi · Cited by 191
Pseudohyperkalemia Caused by Fist Clenching during Phlebotomy
Don, B. R., Sebastian, A., Cheitlin, M., Christiansen, M., & Schambelan, M. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005033221806 · Cited by 132
pH-Independent Fluorescent Chemosensor for Highly Selective Lithium Ion Sensing
Citterio, D., Takeda, J., Kosugi, M., et al. (2006) · Analytical Chemistry · doi:10.1021/ac061674g · Cited by 82
Burnett, R. W., Covington, A. K., Fogh-Andersen, N., Külpmann, W.-R., Lewenstam, A., Maas, A. H. J., Müller-Plathe, O., VanKessel, A. L., & Zijlstra, W. G. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.052 · Cited by 82
Pseudohyperkalemia Due to Pneumatic Tube Transport in a Leukemic Patient
Kellerman, P. S., & Thornbery, J. M. (2005) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2005.06.005 · Cited by 71
Spurious hyperkalaemia due to EDTA contamination: common and not always easy to identify
Cornes, M. P., Ford, C., & Gama, R. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.007241 · Cited by 69
Dimeski, G., & Barnett, R. J. (2005) · Critical Care and Resuscitation · doi:10.1016/s1441-2772(23)01564-8 · Cited by 59
Self-citationIFCC Guideline for sampling, measuring and reporting ionized magnesium in plasma
International Federation of Clinica Ben Rayana, Burnett, R. W., Covington, A. K., D’Orazio, P., Fogh‐Andersen, N., Jacobs, E., Külpmann, W. R., Kuwa, K., Larsson, L., Lewenstam, A., et al. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.001 · Cited by 59
Self-citationCorrection and reporting of potassium results in haemolysed samples
Dimeski, G., Clague, A. E., & Hickman, P. E. (2005) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563053492739 · Cited by 58
Self-citationAre sodium bicarbonate and potassium bicarbonate fully dissociated under physiological conditions?
Wimberley, P. D., Siggaard‐Andersen, O., Fogh‐Andersen, N., & Boink, A. B. T. J. (1985) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365518509160965 · Cited by 54
Sinclair, D., Briston, P., Young, R., & Pepin, N. (2003) · Journal of Clinical Pathology · doi:10.1136/jcp.56.5.385 · Cited by 50
Vermeer, H. J., Steen, G., Naus, A. J. M., Goevaerts, B., Agricola, P. T., & Schoenmakers, C. H. H. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.004 · Cited by 47
An episode of increased hemolysis due to a defective pneumatic air tube delivery system
Ellis, G. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.05.002 · Cited by 46
Serum Ionized Magnesium: Comparison of Results Obtained with Three Ion-Selective Analyzers
Huijgen, H. J., Sanders, R., Cecco, S. A., Rehak, N. N., Sanders, G. T., & Elin, R. J. (1999) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.1999.075 · Cited by 44
Renoe, B. W., McDonald, J. M., & Ladenson, J. H. (1980) · Clinica Chimica Acta · doi:10.1016/0009-8981(80)90234-x · Cited by 43
Sodium measurements in multiple myeloma: two techniques compared.
Ladenson, J. H., Apple, F. S., Aguanno, J. J., & Koch, D. D. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.12.2383 · Cited by 43
Interference of ascorbic acid with chemical analytes
Meng, Q. H., Irwin, W. C., Fesser, J., & Massey, K. L. (2005) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456305774538274 · Cited by 38
Thiocyanate in smokers interferes with the Nova magnesium ion-selective electrode
Rehak, N. N., Cecco, S. A., Niemela, J. E., & Elin, R. J. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.9.1595 · Cited by 28
Calcium and magnesium levels during automated plateletpheresis in normal donors
Das, S. S., Chaudhary, R., Khetan, D., Shukla, J., Agarwal, P., & Mishra, R. (2005) · Transfusion Medicine · doi:10.1111/j.1365-3148.2005.00576.x · Cited by 27
Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters
Fincher, R., Strong, J., & Jackson, J. L. (1998) · American Journal of Critical Care · doi:10.4037/ajcc1998.7.6.439 · Cited by 26
Rayana, M. C. B., Burnett, R. W., Covington, A. K., D’Orazio, P., Fogh‐Andersen, N., Jacobs, E., Külpmann, W. R., Kuwa, K., Larsson, L., Lewenstam, A., et al. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.098 · Cited by 21
Self-citationHeparin interference in whole blood sodium measurements in a pediatric setting
Yip, P. S. F., Chan, M. K., Zielinski, N., & Adeli, K. (2006) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2005.12.006 · Cited by 19
Bicarbonate Interference with Chloride-Ion-Selective Electrodes
Dimeski, G., & Clague, A. E. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.033589 · Cited by 14
Self-citationGlucose interference in direct ion-sensitive electrode sodium measurements
Al-Musheifri, A., & Jones, G. R. D. (2008) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2008.008001 · Cited by 14
The perennial problem with potassium
Trull, A. K., Jackson, C. H., Walsh, S., Thornton, A., Culank, L. S., & McHugh, J. (2004) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456304322664690 · Cited by 13
Are your hands clean enough for point-of-care electrolyte analysis?
Lam, H. S., Chan, M. H. M., Ng, P. C., Wong, W. C. W., Cheung, R. C. K., So, A. K. W., Fok, T. F., & Lam, C. W. K. (2005) · Pathology · doi:10.1080/00313020500169156 · Cited by 13
Bicarbonate Interference with Hitachi Chloride Electrodes
Faulkner, A. M., & Peake, M. J. (1991) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/000456329102800121 · Cited by 11
Heparin Interference with Sodium and Albumin Assays
Karon, B. S., Kempe, K. C., & Scott, M. G. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.4.697 · Cited by 10
Falsely Increased i-STAT Chloride Results for Blood Samples with Increased Urea
Pinckard, J. K., Zahn, J., Ashby, L., Parvin, C. A., & Scott, M. G. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.11.2064 · Cited by 9
Transferability of results obtained for sodium, potassium and chloride ions with different analysers
Rodríguez, J., Sogo, T., Otero, S., & Paz, J. (1998) · Clinica Chimica Acta · doi:10.1016/s0009-8981(98)00081-3 · Cited by 9
Cited by
Electrochemical Sensors and Their Applications: A Review
Baranwal, J., Barse, B., Gatto, G., Broncova, G., & Kumar, A. (2022) · Chemosensors · doi:10.3390/chemosensors10090363 · Cited by 978
Electrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
Badmus, S. O., Amusa, H. K., Oyehan, T. A., & Saleh, T. A. (2021) · Environmental Science and Pollution Research · doi:10.1007/s11356-021-16483-w · Cited by 459
Recent trends in potentiometric sensor arrays—A review
Bratov, A., Abramova, N., & Ipatov, A. (2010) · Analytica Chimica Acta · doi:10.1016/j.aca.2010.08.035 · Cited by 257
Metadata
- Authors
- Dimeski, G., Badrick, T., & John, A. S.
- Venue
- Clinica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2010-03
- Volume
- 411
- Issue
- 5-6
- Pages
- 309-317
- ISSN
- 0009-8981 (ISSN-L)
- OpenAlex
- W2074169638
- Cited by
- 253
- References
- 35
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.