A rapid and reliable method for the quantitation of hydroxychloroquine in serum using turbulent flow liquid chromatography-tandem mass spectrometry

Füzéry, Anna K., Breaud, Autumn R., Emezienna, Nkechinyere, Schools, Sabitha, Clarke, William A.·2013·Clinica Chimica Acta

Abstract

Background Hydroxychloroquine is routinely used in managing systemic lupus erythematosus and rheumatoid arthritis. Whole blood levels are currently measured in the laboratory but at least one study suggests that serum levels may be equally useful. Moreover, serum samples are the preferred matrix type in the clinical laboratory as a result of their reduced complexity compared to whole blood. These observations suggest that the clinical utility of serum hydroxychloroquine levels needs to be reevaluated using larger studies and more robust assays. We report a turbulent flow LC-MS/MS method we developed for this purpose.Methods After protein precipitation from serum with 0.33 mol/l perchloric acid, hydroxychloroquine and its deuterated analog were injected onto a Cyclone turbulent flow column for sample cleanup. Analytical separation was accomplished on a HypersilGold C8 column with a gradient of water and methanol, each containing 0.1% formic acid and 10 mmol/l ammonium formate. Analytes were ionized and detected by electrospray ionization mass spectrometry with multiple reaction monitoring.Results Our method was linear from 15.7 to 2000 ng/ml. Total imprecision at multiple levels was <5% and accuracy was within ±15%. The method showed minimal carryover. Our extraction efficiency was 103% and the matrix factor was 101%. Comparison with a reference laboratory method identified constant bias but good correlation between the 2 methods.Conclusions We present a novel turbulent flow liquid chromatography-tandem mass spectrometry method for quantification of hydroxychloroquine in serum. Our method has comparable sensitivity, selectivity, precision, accuracy, and linearity to previously reported methods. However, it offers simpler sample processing, shorter overall analysis time, and minimal carryover. These characteristics make our method well-suited for efficient analysis of the large number of samples necessary for studies on the clinical utility of serum HQ levels.

Integrity signals

Registry

Crossref · 10.1016/j.cca.2013.02.018

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Hydroxychloroquine levels were measured from EDTA whole blood using liquid chromatography-tandem mass spectrometry, with linearity from 16 to 4000 ng/mL and a coefficient of variation below 3%.

    “Hydroxychloroquine levels were quantified from EDTA whole blood by liquid chromatography-tandem mass spectrometry as described by Chambliss et al, with measurements being linear over a range of 16 to 4000 ng/mL (29). The coefficient of variation was <3%.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Füzéry, A. K., Breaud, A. R., Emezienna, N., Schools, S., & Clarke, W. A.
Affiliations
Johns Hopkins University (US)
Corresponding author
Clarke, William A.
Venue
Clinica Chimica Acta
Publisher
Elsevier BV
Published
2013-06
Volume
421
Pages
79-84
ISSN
0009-8981 (ISSN-L)
OpenAlex
W2033223023
Cited by
45
References
22
Citations by year
2025: 2 · 2024: 4 · 2023: 2 · 2022: 3 · 2021: 6 · 2020: 9 · 2019: 5 · 2018: 1 · 2017: 2 · 2016: 2 · 2015: 5 · 2014: 3 · 2013: 1
FWCI
3.49
Type
journal article
Language
en
Open access
closed
Locations
  • Clinica Chimica Acta (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
Keywords
hydroxychloroquine, serum drug concentration, therapeutic drug monitoring, tandem mass spectrometry, deuterated internal standards, systemic lupus erythematosus, rheumatoid arthritis, sample cleanup, carryover
MeSH terms
Chromatography, Liquid, Humans, Hydroxychloroquine, Lupus Erythematosus, Systemic, Perchlorates, Chemical Precipitation, Sensitivity and Specificity, Time Factors, Spectrometry, Mass, Electrospray Ionization, Tandem Mass Spectrometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review