Cited by 48Analytical Methods in PharmaceuticalsSystemic Lupus Erythematosus ResearchBiosimilars and Bioanalytical Methods

Measurement of hydroxychloroquine in blood from SLE patients using LC-HRMS—evaluation of whole blood, plasma, and serum as sample matrices

Open access
Carlsson, Henrik, Hjorton, Karin, Abujrais, Sandy, Rönnblom, Lars, Åkerfeldt, Torbjörn, Kultima, Kim·2020·Arthritis Research & Therapy

Abstract

Background: Hydroxychloroquine (HCQ) is the standard of care in the treatment of systemic lupus erythematosus (SLE), rheumatoid arthritis (RA), and other inflammatory rheumatic diseases and potentially for the treatment in COVID-19 patients. Determination of HCQ for therapeutic drug monitoring (TDM) can be performed in whole blood (WB), serum, and plasma. Direct comparisons of WB, serum, and plasma levels of HCQ in patients with SLE have not previously been reported. We describe a method for the determination of HCQ in human blood using liquid chromatography-high-resolution mass spectrometry (LC-HRMS) and compare the suitability of the three sample matrices. Methods: A method for the determination of HCQ in human blood using LC-HRMS was developed, validated, and applied for the determination of HCQ levels in WB, serum, and plasma from 26 SLE patients. The reproducibility of the method, in the three matrices, was evaluated using quality control samples and repeated preparations and measurements of patient samples. The performance of the developed method for HCQ measurement in serum was further evaluated by comparison with two previously reported extraction methods. Results: The performance of the presented method demonstrated high accuracy and precision. A large range of HCQ concentrations was observed for the SLE patients in all three matrices (WB, serum, and plasma). The mean levels in WB were approximately two-fold the levels in serum and plasma (813 ng/mL compared to 436 ng/mL and 362 ng/mL, respectively). Spiked quality controls showed high reproducibility for all matrices (coefficient of variation, CV, approx. 5%), whereas in patient samples, equally high-precision was only found using WB as the matrix (CV 3%). The CV for serum and plasma was 14% and 39%, respectively. Two alternative methods applied to serum samples did not demonstrate improved precision. Conclusions: A LC-HRMS method for the measurement of HCQ in human blood was developed and validated. Whole blood was found to be the superior sample matrix in terms of sample reproducibility. Thus, whole blood samples should be used for HCQ analysis when patients are monitored for HCQ treatment effects. The assay is in clinical use to monitor levels of HCQ in patients.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s13075-020-02211-1

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Whole blood is preferred over plasma for measuring hydroxychloroquine because the drug binds to red blood cells and is sequestered in leukocytes.

    “Hydroxychloroquine blood levels are preferred over plasma levels due to binding of hydroxychloroquine to red blood cells and its lysosomal sequestration in leukocytes (28).”

    From Association of Higher Hydroxychloroquine Blood Levels With Reduced Thrombosis Risk in Systemic Lupus Erythematosus (2021) · cites this paper as [28]

    The Conclusions (page unavailable) identify whole blood as the preferred matrix for hydroxychloroquine measurement. The Discussion (page unavailable) attributes its advantage to better reproducibility in patient samples; it does not establish red-blood-cell binding or lysosomal sequestration in leukocytes as the reasons for that preference. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

1 retracted

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Carlsson, H., Hjorton, K., Abujrais, S., Rönnblom, L., Åkerfeldt, T., & Kultima, K.
Affiliations
Uppsala University (SE)
Corresponding author
Kultima, Kim
Venue
Arthritis Research & Therapy
Published
2020-06-01
Volume
22
Issue
1
Pages
125-125
ISSN
  • 1478-6354 (ISSN-L)
  • 1478-6362
OpenAlex
W3026022611
Cited by
48
References
38
Citations by year
2026: 1 · 2025: 4 · 2024: 7 · 2023: 9 · 2022: 11 · 2021: 14 · 2020: 1 · 2018: 1
FWCI
4.53
Type
journal article
Language
en
Open access
Locations
  • Arthritis Research & Therapy (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Uppsala University Publications (Uppsala University) (submittedVersion, other-oa)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Region Uppsala (n.a.)
  • the Swedish Rheumatism Association
  • King Gustaf V's 80-years Foundation
  • the Swedish Society of Medicine
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Life Sciences › Immunology and Microbiology › Immunology › Biosimilars and Bioanalytical Methods
Keywords
hydroxychloroquine, systemic lupus erythematosus, therapeutic drug monitoring, whole blood, plasma, serum, sample matrix comparison, LC-HRMS, assay validation
MeSH terms
Betacoronavirus, COVID-19, SARS-CoV-2, Adult, Aged, Chromatography, Liquid, Female, Humans, Hydroxychloroquine, Lupus Erythematosus, Systemic, Male, Middle Aged, Plasma, Pneumonia, Viral, Mass Spectrometry, Drug Monitoring, Coronavirus Infections, Serum, Young Adult, Pandemics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review