CoChat

Evaluation of four different equations for calculating LDL-C with eight different direct HDL-C assays

Open access
Oliveira, Marcelo Jose Andrade, van Deventer, Hendrick E., Bachmann, Lorin M., Warnick, G. Russell, Nakajima, Katsuyuki, Nakamura, Masakasu, Sakurabayashi, Ikunosuke, Kimberly, Mary M., Shamburek, Robert D., Korzun, William J., Myers, Gary L., Miller, W. Greg, Remaley, Alan T. · 2013 · Clinica Chimica Acta
Cited by 64

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background Low-density lipoprotein-cholesterol (LDL-C) is often calculated (cLDL-C) by the Friedewald equation, which requires high-density lipoprotein-cholesterol (HDL-C) and triglycerides (TG). Because there have been considerable changes in the measurement of HDLC with the introduction of direct assays, several alternative equations have recently been proposed. Methods We compared 4 equations (Friedewald, Vujovic, Chen, and Anandaraja) for cLDL-C, using 8 different direct HDL-C (dHDL-C) methods. LDL-C values were calculated by the 4 equations and determined by the quantification reference method procedure in 164 subjects. Results For normotriglyceridemic samples (TG < 200mg/dl), between 6.2 to 24.8% of all results exceeded the total error goal of 12% for LDL-C, depending on the dHDL-C assay and cLDL-C equation used. Friedewald equation was found to be the optimum equation for most but not all dHDL-C assays, typically leading to less than 10% misclassification of cardiovascular risk based on LDL-C. Hypertriglyceridemic samples (>200 mg/dl) showed a large cardiovascular risk misclassification rate (30 - 50%) for all combinations of dHDL-C assays and cLDL-C equations. Conclusion Friedewald equation showed the best performance for estimating LDL-C, but its accuracy varied considerably depending on the specific dHDL-C assay used. None of the cLDLC equations performed adequately for hypertriglyceridemic samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cca.2013.04.009

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 64

Metadata

Authors
Oliveira, M. J. A., van Deventer, H. E., Bachmann, L. M., Warnick, G. R., Nakajima, K., Nakamura, M., Sakurabayashi, I., Kimberly, M. M., Shamburek, R. D., Korzun, W. J., Myers, G. L., Miller, W. G., & Remaley, A. T.
Venue
Clinica Chimica Acta
Publisher
Elsevier BV
Published
2013-08
Volume
423
Pages
135-140
ISSN
0009-8981 (ISSN-L)
OpenAlex
W1983383397
Cited by
64
References
6
FWCI
3.89
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of four different equations for calculating LDL-C with eight different direct HDL-C assays. https://app.cochat.ai/papers/10.1016/j.cca.2013.04.009
The paper
Oliveira, M. J. A., van Deventer, H. E., Bachmann, L. M., Warnick, G. R., Nakajima, K., Nakamura, M., Sakurabayashi, I., Kimberly, M. M., Shamburek, R. D., Korzun, W. J., Myers, G. L., Miller, W. G., & Remaley, A. T. (2013). Evaluation of four different equations for calculating LDL-C with eight different direct HDL-C assays. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2013.04.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.