Evaluation of accuracy of FAD-GDH- and mutant Q-GDH-based blood glucose monitors in multi-patient populations
Abstract
Background Glucose dehydrogenases have been highly promoted to high-accuracy blood glucose (BG) monitors. The flavin adenine dinucleotide glucose dehydrogenase (FAD-GDH) and mutant variant of quinoprotein glucose dehydrogenase (Mut. Q-GDH) are widely used in high-performance BG monitors for multi-patient use. Therefore we conducted accuracy evaluation of the GDH monitors, FAD-GDH-based GM700 and Mut. Q-GDH-based Performa. Methods Different patients were enrolled: patients with and without diabetes, patients receiving respiratory therapies, hemodialysis (HD) and peritoneal dialysis (PD) patients, and neonates. The accuracy evaluation of FAD-GDH- and Mut. Q-GDH-based monitors referred to ISO 15197:2013 which applies new criteria for the minion accuracy requirements: more than 95% of the blood glucose readings shall fall within ±15mg/dL of the reference method at glucose concentration <100mg/dL and within ±15% of the reference method at glucose concentration ≥100mg/dL. Bland-Altman plots were used to evaluate the 2 GDH monitors as well. Results Bland-Altman plots visualized excellent precision of the BG monitors. The 95% limit agreement of overall results for the FAD-GDH-based monitors was within ±12% and that for the Mut. Q-GDH-based monitors was from -10 to +17%. Both BG monitors met the accuracy requirements of ISO 15197:2013. The FAD-GDH-based monitor performed better with neonates and patients with and without diabetes, and the Mut. Q-GDH-based monitor performed better with HD and PD patients. Conclusions Analytical results prove that the GDH-based monitors tolerate a broad BG concentration range, are oxygen independent, have BG specificity, and have minimal interference from hematocrit. The GDH-based monitors are reliable for multi-patient use.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It is difficult to make direct comparisons due to differences in methods among these studies; however, the accuracy reported here for the Contour ® Next Link 2.4 BGMS is similar to or higher than the other glucose monitoring systems.”
From Accuracy and user performance evaluation of the Contour Next Link 2.4 blood glucose monitoring system (2015) · cites this paper as [25]
Citations
The citation lists haven’t been fetched yet
References 36 · Cited by 15
Research works printed but not linked: 33
- Clark, 1962, Electrode systems for continuous monitoring in cardiovascular surgery, Ann N Y Acad Sci, 102, 29, 10.1111/j.1749-6632.1962.tb13623.x · DOI · Paper page
- Ferri, 2011, Review of glucose oxidases and glucose dehydrogenases: a bird's eye view of glucose sensing enzymes, J Diabetes Sci Technol, 5, 1068, 10.1177/193229681100500507 · DOI
- Wilson, 1992, Glucose oxidase: an ideal enzyme, Biosens Bioelectron, 7, 165, 10.1016/0956-5663(92)87013-F · DOI
- Wang, 2001, Glucose biosensors: 40years of advances and challenges, Electroanalysis, 13, 983, 10.1002/1521-4109(200108)13:12<983::AID-ELAN983>3.0.CO;2-# · DOI
- Tang, 2001, Oxygen effects on glucose meter measurements with glucose dehydrogenase- and oxidase-based test strips for point-of-care testing, Crit Care Med, 29, 1062, 10.1097/00003246-200105000-00038 · DOI
- Wong, 2008, Glucose oxidase: natural occurrence, function, properties and industrial applications, Appl Microbiol Biotechnol, 78, 927, 10.1007/s00253-008-1407-4 · DOI
- Zafar, 2012, Characterization of different FAD-dependent glucose dehydrogenases for possible use in glucose-based biosensors and biofuel cells, Anal Bioanal Chem, 402, 2069, 10.1007/s00216-011-5650-7 · DOI
- Yamaoka, 2007, A disposable electrochemical glucose sensor using catalytic subunit of novel thermostable glucose dehydrogenase, Open Biotechnol J, 1, 26, 10.2174/1874070700701010026 · DOI
- Flore, 2009, Analytical interferences in point-of-care testing glucometers by icodextrin and its metabolites: an overview. Peritoneal dialysis international, J Int Soc Perit Dial, 29, 377, 10.1177/089686080902900403 · DOI
- Frias, 2010, Review of adverse events associated with false glucose readings measured by GDH-PQQ-based glucose test strips in the presence of interfering sugars, Diabetes Care, 33, 728, 10.2337/dc09-1822 · DOI · Paper page
- FDA, 2009, FDA Public Health Notification: potentially fatal errors with GDH-PQQ glucose monitoring technology, US Food Drug Adm
- Igarashi, 2004, Engineering PQQ glucose dehydrogenase with improved substrate specificity. Site-directed mutagenesis studies on the active center of PQQ glucose dehydrogenase, Biomol Eng, 21, 81, 10.1016/j.bioeng.2003.12.001 · DOI
- Igarashi, 1999, Construction and characterization of mutant water-soluble PQQ glucose dehydrogenases with altered K(m) values—site-directed mutagenesis studies on the putative active site, Biochem Biophys Res Commun, 264, 820, 10.1006/bbrc.1999.1157 · DOI
- Tsujimura, 2006, Novel FAD-dependent glucose dehydrogenase for a dioxygen-insensitive glucose biosensor, Biosci Biotechnol Biochem, 70, 654, 10.1271/bbb.70.654 · DOI
- Freckmann, 2010, System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197, Diabetes Technol Ther, 12, 221, 10.1089/dia.2009.0128 · DOI · Paper page
- Freckmann, 2012, System accuracy evaluation of 43 blood glucose monitoring systems for self-monitoring of blood glucose according to DIN EN ISO 15197, J Diabetes Sci Technol, 6, 1060, 10.1177/193229681200600510 · DOI · Paper page
- Baumstark, 2012, Lot-to-lot variability of test strips and accuracy assessment of systems for self-monitoring of blood glucose according to ISO 15197, J Diabetes Sci Technol, 6, 1076, 10.1177/193229681200600511 · DOI
- Hsu, 2009, Assessing the quality of Bionime self-monitoring blood glucose system Rightest GM110: a critical evaluation of interference and ambient circumstances, Clin Chim Acta Int J Clin Chem, 402, 119, 10.1016/j.cca.2008.12.029 · DOI
- Kuo, 2011, Accuracy and precision evaluation of seven self-monitoring blood glucose systems, Diabetes Technol Ther, 13, 596, 10.1089/dia.2010.0223 · DOI
- FDA, 1996, Points to consider for portable blood glucose monitoring devices intended for bedside use in the neonate nursery, US Food Drug Adm
- Mahoney, 2007, Glucose measurement: confounding issues in setting targets for inpatient management: response to Dungan et al, Diabetes Care, 30, e71, 10.2337/dc07-0522 · DOI
- Karon, 2008, Evaluation of the impact of hematocrit and other interference on the accuracy of hospital-based glucose meters, Diabetes Technol Ther, 10, 111, 10.1089/dia.2007.0257 · DOI
- Janssen, 1998, Positive interference of icodextrin metabolites in some enzymatic glucose methods, Clin Chem, 44, 2379, 10.1093/clinchem/44.11.2379 · DOI
- Aziz, 2004, Screening guidelines for newborns at risk for low blood glucose, J Paediatr Child Health, 9, 723, 10.1093/pch/9.10.723 · DOI · Paper page
- Adamkin, 2011, Postnatal glucose homeostasis in late-preterm and term infants, Pediatrics, 127, 575, 10.1542/peds.2010-3851 · DOI · Paper page
- Deshpande, 2005, The investigation and management of neonatal hypoglycaemia, Semin Fetal Neonatal Med, 10, 351, 10.1016/j.siny.2005.04.002 · DOI
- Halamek, 1997, Neonatal hypoglycemia, Part I: background and definition, Clin Pediatr, 36, 675, 10.1177/000992289703601201 · DOI
- Mahoney, 2007, Assessing the quality of glucose monitor studies: a critical evaluation of published reports, Clin Chem, 53, 1122, 10.1373/clinchem.2006.083493 · DOI · Paper page
- Klonoff, 2008, Consensus report of the coalition for clinical research-self-monitoring of blood glucose, J Diabetes Sci Technol, 2, 1030, 10.1177/193229680800200612 · DOI · Paper page
- Thorpe, 2013, Assessing the quality of publications evaluating the accuracy of blood glucose monitoring systems, Diabetes Technol Ther, 15, 253, 10.1089/dia.2012.0265 · DOI
- Nichols, 2005, What is accuracy and how close must the agreement be?, Diabetes Technol Ther, 7, 558, 10.1089/dia.2005.7.558 · DOI
- Heinemann, 2012, Accuracy in blood glucose measurement: what will a tightening of requirements yield?, J Diabetes Sci Technol, 6, 435, 10.1177/193229681200600232 · DOI
- Mahoney, 2007, Assessing glucose monitor performance—a standardized approach, Diabetes Technol Ther, 9, 545, 10.1089/dia.2007.0245 · DOI
Metadata
- Authors
- Huang, T.-Y., Chang, H.-W., Tsao, M.-F., Chuang, S.-M., Ni, C.-C., Sue, J.-W., Lin, H.-C., & Hsu, C.-T.
- Affiliations
- Taipei Medical University Hospital (TW)
- Chung Shan Medical University (TW)
- Corresponding author
- Lin, Hsiu-Chen
- Hsu, Cheng-Teng
- Venue
- Clinica Chimica Acta
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 433
- Pages
- 28-33
- ISSN
- 0009-8981 (ISSN-L)
- OpenAlex
- W2025267443
- Cited by
- 15
- References
- 36
- Citations by year
- 2025: 1 · 2024: 1 · 2022: 1 · 2021: 1 · 2018: 3 · 2017: 2 · 2016: 3 · 2015: 3
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinica Chimica Acta (publishedVersion)
- PubMed (publishedVersion)
- Taipei Medical University Repository (submittedVersion)
- Funders
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Keywords
- glucose dehydrogenase, quinoprotein glucose dehydrogenase, blood glucose meters, glucose meter accuracy, ISO 15197:2013, hemodialysis patients, peritoneal dialysis patients, neonates, diabetes mellitus, respiratory care, hematocrit interference
- MeSH terms
- Adult, Aged, Aged, 80 and over, Blood Chemical Analysis, Blood Glucose, Flavin-Adenine Dinucleotide, Female, Glucose Dehydrogenases, Humans, Infant, Newborn, Male, Middle Aged, Mutation, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of accuracy of FAD-GDH- and mutant Q-GDH-based blood glucose monitors in multi-patient populations. https://app.cochat.ai/papers/10.1016/j.cca.2014.02.023
- The paper
- Huang, T.-Y., Chang, H.-W., Tsao, M.-F., Chuang, S.-M., Ni, C.-C., Sue, J.-W., Lin, H.-C., & Hsu, C.-T. (2014). Evaluation of accuracy of FAD-GDH- and mutant Q-GDH-based blood glucose monitors in multi-patient populations. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2014.02.023