CoChat

The PrecivityAD™ test: Accurate and reliable LC-MS/MS assays for quantifying plasma amyloid beta 40 and 42 and apolipoprotein E proteotype for the assessment of brain amyloidosis

Open access
Kirmess, Kristopher M., Meyer, Matthew R., Holubasch, Mary S., Knapik, Stephanie S., Hu, Yan, Jackson, Erin N., Harpstrite, Scott E., Verghese, Philip B., West, Tim, Fogelman, Ilana, Braunstein, Joel B., Yarasheski, Kevin E., Contois, John H. · 2021 · Clinica Chimica Acta
Cited by 128

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

Background There is an unmet need for an accessible, less invasive, cost-effective method to facilitate clinical trial enrollment and aid in clinical Alzheimer’s disease (AD) diagnosis. APOE genotype affects the clearance and deposition of amyloid-beta (Aβ) with APOE 4 carriers having increased risk while APOE 2 alleles appear to be protective. Lower plasma Aβ42/40 correlates with brain amyloidosis. In response, C 2 N has developed the PrecivityAD™ test; plasma LC-MS/MS assays for Aβ isoform quantitation and qualitative APOE isoform-specific proteotyping. Methods In accord with CLIA standards, we developed and validated assay performance: precision, accuracy, linearity, limit of detection (LoD), interferences. RESULTS. Within-day precision varied from 1.5–3.0% (Aβ40) and 2.5–8.4% (Aβ42). Total (within-lab) variability was 2.7–7.7% (Aβ40) and 3.1–9.5% (Aβ42). Aβ40 quantitation was linear from 10 to 1780 pg/mL; Aβ42 was linear from 2 to 254 pg/mL. LoD was 11 and 2 pg/mL for Aβ40 and Aβ42, respectively. APOE proteotypes were 100% concordant with genotype, while LoD (fM) was much lower than APOE concentrations observed in plasma (mM). CONCLUSIONS. The PrecivityAD™ assays are precise, accurate, sensitive, and linear over a wide analytical range, free from significant interferences, and suitable for use in the clinical laboratory.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.cca.2021.05.011

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 128

Metadata

Authors
Kirmess, K. M., Meyer, M. R., Holubasch, M. S., Knapik, S. S., Hu, Y., Jackson, E. N., Harpstrite, S. E., Verghese, P. B., West, T., Fogelman, I., Braunstein, J. B., Yarasheski, K. E., & Contois, J. H.
Venue
Clinica Chimica Acta
Publisher
Elsevier BV
Published
2021-08
Volume
519
Pages
267-275
ISSN
0009-8981 (ISSN-L)
OpenAlex
W3160783596
Cited by
128
References
17
FWCI
11.36
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The PrecivityAD™ test: Accurate and reliable LC-MS/MS assays for quantifying plasma amyloid beta 40 and 42 and apolipoprotein E proteotype for the assessment of brain amyloidosis. https://app.cochat.ai/papers/10.1016/j.cca.2021.05.011
The paper
Kirmess, K. M., Meyer, M. R., Holubasch, M. S., Knapik, S. S., Hu, Y., Jackson, E. N., Harpstrite, S. E., Verghese, P. B., West, T., Fogelman, I., Braunstein, J. B., Yarasheski, K. E., & Contois, J. H. (2021). The PrecivityAD™ test: Accurate and reliable LC-MS/MS assays for quantifying plasma amyloid beta 40 and 42 and apolipoprotein E proteotype for the assessment of brain amyloidosis. Clinica Chimica Acta. https://doi.org/10.1016/j.cca.2021.05.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.